- add to Notepad
- HTML-Datasheet
- no Datasheet available
- Productdetails as PDF
| Model | Measurement Range | Meas. Channels | Resol. | Sample Rate | Interface | Operation | ||
|---|---|---|---|---|---|---|---|---|
![]() | GL220 Compact datalogger for 10 measurement channels | ±20mV ... ±50V, thermocouples, humidity | 10 | 16 bit* | per channel: | USB | stand-alone, | |
![]() | GL820 Datalogger for up to 200 measurement channels | ±20mV ... ±50V, thermocouples, Pt100, JPt100, Pt1000, humidity | 20 to 200 | 16 bit* | per channel: | Ethernet, | stand-alone, | |
![]() | GL900-4 High-speed datalogger with parallel signal processing | ±20mV ... ±500V, thermocouples, humidity | 4 | 14 bit | per channel: | Ethernet, | stand-alone, | |
![]() | GL900-8 High-speed datalogger with parallel signal processing | ±20mV ... ±500V, thermocouples, humidity | 8 | 14 bit | per channel: | Ethernet, | stand-alone, | |
![]() | WR300 | WR310 Multifunctional thermo array recorder with a 210 mm display | 50 mV ... 200 V, strain gauge, frequency, thermocouples | 2 to 16 | 12 bit | per channel: | Ethernet, | stand-alone, PC based, HTTP |
*effective resolution: 1/40000 of measuring full range
GLET modules - accessories for datalogger series GL
| Model | Meas. Range | Meas. Channels | Resol. | Sample Rate | Interface | Operation | ||
|---|---|---|---|---|---|---|---|---|
![]() | DI-710-UH | DI-710-EL Data acquisition system with 16 channels | ±1.25 V ... | 16 | 14 bit | Sum: | Ethernet, | PC based | |
![]() | DI-710-UL Data acquisition system with 16 channels | ±10 mV ... | 16 | 14 bit | Sum: | Ethernet, | PC based | |
![]() | DI-718B-U | DI-718B-E Data acquisition system for 8B amplifier, with 8 channels | ±5 V via 8B amplifier | 8 | 14 bit | Sum: | Ethernet, | PC based | |
![]() | DI-718Bx Data acquisition system for 8B amplifier, with 16 channels | ±5 V via 8B amplifier | 16 | 14 bit | Sum: | Ethernet | PC based | |
![]() | DI-720 Data acquisition system with 32 channels | ±1.25 V ... | 32 | 14 bit | Sum: | Ethernet, | PC based | |
![]() | DI-730 Data acquisition system with 24 channels, 8 of them with wide range | ±10 mV ... | 8 + 16 | 14 bit | all channels: | Ethernet, | PC based |
| Model | Meas. Range | Meas. Channels | Resol. | Sample Rate | Interface | Operation | ||
|---|---|---|---|---|---|---|---|---|
![]() | DI-145 Low priced measurement data acquisition system | ±10 V | 4 x analog, | 10 bit | Sum: | USB | PC based | |
![]() | DI-149 Low priced measurement data acquisition system | ±10 V | 8 x analog, | 10 bit | Sum: | USB | PC based | |
![]() | EL-USB-1 EasyLog Datalogger for temperature with 2 alarm thresholds | -35 ... +80 °C | 1 | 0.5 K | 10 s to | USB | stand-alone, | |
![]() | EL-USB-1-LCD EasyLog Datalogger for temperature with display and with 2 alarm thresholds | -35 ... +80 °C | 1 | 0.1 K | 10 s to | USB | stand-alone, | |
![]() | EL-USB-1-RCG Datalogger for temperature in steel enclosure, rechargeable battery and with 2 alarm thresholds | -20 ... +60 °C | 1 | 0.1 K | 1 s to | USB | stand-alone, | |
![]() | EL-USB-1-PRO High temperature datalogger, steel enclosure, 2 alarm thresholds | -40 ... +125 °C | 1 | 0.1 K | 1 s to | USB | stand-alone, | |
![]() | EL-USB-2 Datalogger for temperature, humidity and dew point, 2x 2 alarm thresholds | -35 ... +80 °C | 2 | 0.5 K | 10 s to | USB | stand-alone | |
![]() | EL-USB-2+ Datalogger with higher accuracy, 2x 2 alarm thresholds | -35 ... +80 °C | 2 | 0.5 K | 10 s to | USB | stand-alone | |
![]() | EL-USB-2-LCD EasyLog temperature and humidity logger with display and 2x 2 alarm thresholds | -35 ... +80 °C | 2 | 0.5 K | 10 s to | USB | stand-alone | |
![]() | EL-USB-2-LCD+ Temperature and humidity logger with display, higher accuracy and 2x 2 alarm thresholds | -35 ... +80 °C | 2 | 0.5 K | 10 s to | USB | stand-alone | |
![]() | EL-USB-3 EasyLog voltage datalogger, 2 alarm thresholds | 0 ... 30 V | 1 | 50 mV | 1 s to | USB | stand-alone | |
![]() | EL-USB-4 Current loop datalogger, 2 alarm thresholds | 4 ... 20 mA | 1 | 0.05 mA | 1 s to | USB | stand-alone | |
![]() | EL-USB-5 Datenlogger event, state and counter | 3 ... 28 VDC | 1 | 200 ms (event) | USB | stand-alone | ||
![]() | EL-USB-CO Datalogger carbonmonoxide (CO), 2 alarm thresholds | 0 ... 1000 ppm CO | 1 | 0.5 ppm CO | 10 s to | USB | stand-alone | |
![]() | EL-USB-RT Real-time datalogger for thermocouples, humidity and dew point | -20 ... +70 °C | 2 | 1 s | USB | stand-alone | ||
![]() | EL-USB-TC Datalogger for thermocouples, 2 alarm thresholds | K:-200...+1300°C | 1 | 0.5 K | 1 s to | USB | stand-alone | |
![]() | EL-USB-TC-LCD Datalogger for thermocouples with display and 2 alarm thresholds | K:-200...+1300°C | 1 | 0.5 K | 1 s to | USB | stand-alone | |
![]() | EL-DataPad Portable Viewer for EL-USB Temperature Data Loggers | Compatible data loggers: | ||||||
| Model | Host Instrument | Sample Rate | Language | Operating System | ||
|---|---|---|---|---|---|---|
![]() | WinDaq/Pro Software for measurement equipment configuration and data recording on PC with the maximum sample rate of the hardware | DI-720 | depending on hardware, the same for each channel | English | Windows® 2000 | |
![]() | WinDaq/Pro+ Software for measurement equipment configuration and to record the data on PC with the maximum sample rate of the hardware | DI-720 | depending on hardware, each channel individually | English | Windows® 2000 | |
![]() | WinDaq/HS Software for measurement equipment configuration and data recording on PC with the maximum sample rate of the hardware | DI-14x | depending on hardware, the same for each channel | English | Windows® 2000 | |
![]() | WinDaq/XL Plug-in for real-time transmission of the data to Microsoft® Excel® | DI-19x | - | English | Windows® 2000 | |
![]() | midiLogger Software Free software for configuration, recording and analysis of the data, export to ASCII,Excel® and FlexPro 7 | GL200 | depending on hardware | German | Windows® 2000 | |
![]() | EL-WIN-USB Free software for configuration, recording and analysis of the measurement data of EasyLog data loggers | EL-USB data loggers | depending on hardware | English |
| Model | Features | ||
|---|---|---|---|
![]() | InnoBeamer® LX2 USB data acquisition device for IEPE vibration sensors, easy to use system for PC-based vibration measurement and analysis | Frequency range: 0.1 ... 3200 Hz | |
![]() | InnoBeamer® X2 USB data acquisition device for IEPE vibration sensors, easy to use system for PC-based vibration measurement and analysis | Frequency range: 0.1 ... 40000 Hz | |
![]() | InnoMeter® When vibrations are measured as significant parameters, the InnoMeters are applied. | The InnoMeters in Standard and in Pro Version are highly universal measuring instruments for vibration parameters.They can be adapted to parameters from numerous vibration standards. Measurands: acceleration, velocity, displacement | |
![]() | InnoPlotter® When vibration parameters are measured and controlled for a longer time, the InnoPlotters are suitable | The InnoPlotters in Standard and in Pro Version are universal digital strip chart recorders for vibration parameters.The Pro Version includes two integrators and is consequently able to process not only vibration acceleration, but alsovibration velocity and displacement. | |
![]() | InnoLogger® For the monitoring of vibration parameters and their logging for later analysis | Rotating parts in drives, gears, pumps, fans and many other technical products cause perturbing vibrations.Impulse-like loads, e.g. from a vibratory pile driver in the construction-field, generate problems as well. | |
![]() | InnoScope® The InnoScopes allow the signals‘ shape analysis of fast vibration and shock processes in time domain.These processes are acquired and measured with high resolution and can be exported for documentation or postprocessing. | Another field of application is the determination of natural frequencies. The measurement object is stimulated impulse-like,the InnoScope triggers the event and displays the time course of the signal. A coupled InnoAnalyzer analyzes the triggered timesignal and displays it in the frequency domain simultaneously. Natural frequencies can be read off at once. | |
![]() | InnoAnalyzer® For the frequency analysis of vibrations | Rotating parts in drives, gears, pumps, fans and many other technical products cause perturbing vibrations. Often numerousparts with different rotation speed cause mechanical vibrations so that a superposition of frequencies is generated. | |
![]() | InnoAnalyzer® Speed Different rotation speeds cause different vibrations since the measurement objects develop or donot develop resonant behaviour at certain rotation speeds. | These differences become obviously when measuring run-up or coast-down curves. A rotor changes its rotation speed and excitesdifferent frequencies of the system. The InnoAnalyzers Speed measure the vibration level at the rotation speed or a multipleand graphically indicate magnitude and phase at the respective rotation speed. | |
![]() | InnoBalancer® The InnoBalancers are used for the reduction of vibrations. | The InnoBalancers allow a purposeful reduction of the vibration by balancing.Both discoidal and longish rotors can be balanced systematically and fast. | |
![]() | InnoMeter® HVM 5349:2001 Human hand-arm vibration measurement acc. to EN ISO 5349:2001 and EC Directive 2002/44/EC | If hand held machines or workpieces transmit strong vibrations to the operator, a decreased performance and even diseases in blood vessels, nerves, bones,joints, muscles or the connective tissue might develop. For this reason, divers guidelines stipulate measurements acc. to EN ISO 5349, which determinesthe impact on the human hand-arm-system. | |
![]() | InnoMeter® HVM 2631:1997 Human whole-body vibration measurement acc. to EN ISO2631:1997 and EC Directive 2002/44/EC | If strong vibrations are transmitted to human beings, a decreased performance and even diseases in blood vessels, nerves, bones,joints, muscles or connective tissue might develop. For this reason, divers guidelines stipulate measurements acc. to ISO2631,which assesses the vibration impact on human beings. | |
![]() | InnoMeter® HVM 6954:2001 Vibration measurement on ships | On board passenger and merchant vessels vibrations can occur, which may negatively interfere with the work of the crew or which maydiminish the comfort of passengers and crew. In order to assess complaints or to prevent them, measurements acc. to DIN ISO 6954:2001are suitable, since they allow the evaluation of the vibration severity with regard to habitability on board ships. | |
![]() | InnoMeter® 4150-3 The InnoMeter 4150-3 was developed for the measurement of vibrations on buildings acc. to the German standard DIN 4150-3. | Vibrations from heavy building activities, traffic, machine operation or also detonations affect existing building stock. The InnoMeter4150-3 measures these vibrations, valuates acc. to the standard immediately and can inform about the vibrations occured at any time. | |
![]() | InnoMeter® 3834 The InnoMeter 3834 was developed for the measurement of vibrations on wind energy systems acc. to German standard VDI 3834 | This instrument allows the measurement and analysis of vibrations on both building constructions (like tower and generator house)and machinery components, like rotor, gear and generator. |