? Explanation
  • add to Notepad
  • HTML-Datasheet
  • no Datasheet available
  • Productdetails as PDF

Dataloggers with Integrated Display
Symboldescription: show Datasheet add to Notepad Productdetails as PDF

ModelMeasurement RangeMeas. ChannelsResol.Sample RateInterfaceOperation
GL220
Compact datalogger for 10 measurement channels

±20mV ... ±50V, thermocouples, humidity

10

16 bit*

per channel:
10 ms to 1 h
(depending on channel number)

USB

stand-alone,
PC based,
USB-HD

GL820
Datalogger for up to 200 measurement channels

±20mV ... ±50V, thermocouples, Pt100, JPt100, Pt1000, humidity

20 to 200

16 bit*

per channel:
10 ms to
1 h
(depending on channel number)

Ethernet,
USB

stand-alone,
PC based,
FTP,
HTTP

GL900-4
High-speed datalogger with parallel signal processing

±20mV ... ±500V, thermocouples, humidity

4

14 bit

per channel:
10 µs to
1 min

Ethernet,
USB

stand-alone,
PC based,
FTP,
HTTP

GL900-8
High-speed datalogger with parallel signal processing

±20mV ... ±500V, thermocouples, humidity

8

14 bit

per channel:
10 µs to
1 min

Ethernet,
USB

stand-alone,
PC based,
FTP,
HTTP

WR300 | WR310
Multifunctional thermo array recorder with a 210 mm display

50 mV ... 200 V, strain gauge, frequency, thermocouples

2 to 16

12 bit
to
16 bit

per channel:
1 µs to 10 µs

Ethernet,
USB

stand-alone, PC based, HTTP

*effective resolution: 1/40000 of measuring full range

GLET modules - accessories for datalogger series GL
Symboldescription: show Datasheet add to Notepad Productdetails as PDF

ModelHost InstrumentConnectionSupply VoltageDimensions WxHxD[mm]
GLET-IU
Passive modular enclosures for conversion of (0)4 ... 20 mA to (0)1 ... 5 V

GL220
GL820 / GL800
GL900

jack and/or
BNC

--

45 x 115 x 90 mm

GLET-B513-KA-BA4
Passive modular enclosure for trigger inputs, logic inputs and alarm outputs as open collector

GL220
GL820 / GL800
GL900

jacks

--

45 x 115 x 90 mm

GLET-B513-KA-BA4-REL
Active modular enclosure for 1 trigger, 2 logic inputs and 3 alarm outputs via relay contacts

GL220
GL820 / GL800
GL900

jacks

24 VDC ±5 %

45 x 115 x 90 mm

GLET-SU
Active modular enclosures for active transducers / sensors with voltage output, 1 and 2 channels

GL220
GL820 / GL800
GL900

connector,
jack or BNC

24 VDC ±5 %

45 x 115 x 90 mm

GLET-SI
Active modular enclosures for active transducers/sensors with current signal, 1 and 2 channels

GL220
GL820 / GL800
GL900

connector,
jack or BNC

24 VDC ±5 %

45 x 115 x 90 mm

GLET-Module GLET-2GSKGLET-SG2K
Active modular enclosures with 2 channel strain gauge amplifier

GL220
GL820 / GL800
GL900

connector,
jack or BNC

24 VDC ±5 %

45 x 115 x 90 mm

GLET-Module GLET-8B4KGLET-8B4K
Active modular enclosures with base rack for up to 4 8B-module amplifiers

GL220
GL820 / GL800
GL900

connector,
jack or BNC

24 VDC ±5 %

74 x 115 x 175 mm

Stand-alone Dataloggers
Symboldescription: show Datasheet add to Notepad Productdetails as PDF

ModelMeasurement RangeMeasurement ChannelsResol.Sample RateInterfaceOperation
DI-710-UHS | DI-710-EHS
Datalogger with 16 channels, recording to SD-cards

±1.25 V ...
±10 V

16

14 bit

Sum:
0.0017 S/s ... 10000 S/s
(PC with WinDaq/HS: 4800 S/s)

Ethernet,
USB

SD card
PC based

DI-710-ULS | DI-710-ELS
Datalogger with 16 channels, recording to SD-cards

±10 mV ...
±10 V

16

14 bit

Sum:
0.0017 S/s ... 10000 S/s
(PC with WinDaq/HS: 4800 S/s)

Ethernet,
USB

SD card
PC based

DI-718B-US | DI-718B-ES
Datalogger for 8B amplifier which records to SD-cards (8 channels)

±5 V via 8B amplifier

8

14 bit

Sum:
0.0017 S/s ... 10000 S/s
(PC with WinDaq/HS: 4800 S/s)

Ethernet
USB

SD card
PC based

DI-718Bx
Datalogger for 8B amplifier which records to SD-cards (16 channels)

±5 V via 8B amplifier

16

14 bit

Sum:
0.0017 S/s ... 10000 S/s
(PC with WinDaq/HS: 4800 S/s)

Ethernet

SD card
PC based

PC-based Data Acquisition Systems
Symboldescription: show Datasheet add to Notepad Productdetails as PDF

ModelMeas. RangeMeas. ChannelsResol.Sample RateInterfaceOperation
DI-710-UH | DI-710-EL
Data acquisition system with 16 channels

±1.25 V ...
±10 V

16

14 bit

Sum:
0.0034 S/s ... 1108 S/s
(WinDaq/HS: 4800 S/s)

Ethernet,
USB

PC based

DI-710-UL
Data acquisition system with 16 channels

±10 mV ...
±10 V

16

14 bit

Sum:
0.0034 S/s ... 1108 S/s
(WinDaq/HS: 4800 S/s)

Ethernet,
USB

PC based

DI-718B-U | DI-718B-E Data acquisition system for 8B amplifier, with 8 channels

±5 V via 8B amplifier

8

14 bit

Sum:
0.0034 S/s ... 1108 S/s
(WinDaq/HS: 4800 S/s)

Ethernet,
USB

PC based

DI-718Bx
Data acquisition system for 8B amplifier, with 16 channels

±5 V via 8B amplifier

16

14 bit

Sum:
0.0034 S/s ... 1108 S/s
(WinDaq/HS: 4800 S/s)

Ethernet

PC based

DI-720
Data acquisition system with 32 channels

±1.25 V ...
±10 V

32

14 bit

Sum:
180 kS/s (E)
200 kS/s (U)
250 kS/s (P)

Ethernet,
USB,
Parallel port

PC based

DI-730
Data acquisition system with 24 channels, 8 of them with wide range

±10 mV ...
±1000 V
and
±1.25 V ...
±10 V

8 + 16

14 bit

all channels:
180 kS/s (E)
200 kS/s (U)
250 kS/s (P)

Ethernet,
USB,
Parallel port

PC based

Low-cost Dataloggers and Starter Kits
Symboldescription: show Datasheet add to Notepad Productdetails as PDF

ModelMeas. RangeMeas. ChannelsResol.Sample RateInterfaceOperation
DI-145
Low priced measurement data acquisition system

±10 V

4 x analog,
2 x digital

10 bit

Sum:
0.44 S/min ... 240 S/s

USB

PC based

DI-149
Low priced measurement data acquisition system

±10 V

8 x analog,
4 x digital

10 bit

Sum:
11.4 S/s ... 240 S/s
(WinDaq/HS: 10000 S/s)

USB

PC based

EL-USB-1
EasyLog Datalogger for temperature with 2 alarm thresholds

-35 ... +80 °C
(-31 ... +176 °F)

1

0.5 K
(1 °F)

10 s to
12 h

USB

stand-alone,
IP67

Datalogger EL-USB-1-LCDEL-USB-1-LCD
EasyLog Datalogger for temperature with display and with 2 alarm thresholds

-35 ... +80 °C
(-31 ... +176 °F)

1

0.1 K
(0,2 °F)

10 s to
12 h

USB

stand-alone,
IP67

EL-USB-1-RCG
Datalogger for temperature in steel enclosure, rechargeable battery and with 2 alarm thresholds

-20 ... +60 °C
(-4 ... +140 °F)

1

0.1 K
(0.2 °F)

1 s to
12 h

USB

stand-alone,
IP67

EL-USB-1-PRO
High temperature datalogger, steel enclosure, 2 alarm thresholds

-40 ... +125 °C
(-40 ... +257 °F)

1

0.1 K
(0.2 °F)

1 s to
12 h

USB

stand-alone,
IP67

EL-USB-2
Datalogger for temperature, humidity and dew point, 2x 2 alarm thresholds

-35 ... +80 °C
(-31 ... +176 °F)
0 ... 100 % RH

2

0.5 K
(1 °F)
0,5 % RH

10 s to
12 h

USB

stand-alone

EL-USB-2+
Datalogger with higher accuracy, 2x 2 alarm thresholds

-35 ... +80 °C
(-31 ... +176 °F)
0 ... 100 % RH

2

0.5 K
(1 °F)
0.5 % RH

10 s to
12 h

USB

stand-alone

EL-USB-2-LCD
EasyLog temperature and humidity logger with display and 2x 2 alarm thresholds

-35 ... +80 °C
(-31 ... +176 °F)
0 ... 100 % RH

2

0.5 K
(1 °F)
0.5 % RH

10 s to
12 h

USB

stand-alone

EL-USB-2-LCD+
Temperature and humidity logger with display, higher accuracy and 2x 2 alarm thresholds

-35 ... +80 °C
(-31 ... +176 °F)
0 ... 100 % RH

2

0.5 K
(1 °F)
0.5 % RH

10 s to
12 h

USB

stand-alone

EL-USB-3
EasyLog voltage datalogger, 2 alarm thresholds

0 ... 30 V

1

50 mV

1 s to
12 h

USB

stand-alone

EL-USB-4
Current loop datalogger, 2 alarm thresholds

4 ... 20 mA

1

0.05 mA

1 s to
12 h

USB

stand-alone

EL-USB-5
Datenlogger event, state and counter

3 ... 28 VDC

1

200 ms (event)
500 ms (status)
10 ms (counter)
Minimum

USB

stand-alone

EL-USB-CO
Datalogger carbonmonoxide (CO), 2 alarm thresholds

0 ... 1000 ppm CO

1

0.5 ppm CO

10 s to
5 min

USB

stand-alone

EL-USB-RT
Real-time datalogger for thermocouples, humidity and dew point

-20 ... +70 °C
(-4 ... +158 °F)
0 ... 100 % RH

2

1 s

USB

stand-alone

EL-USB-TC
Datalogger for thermocouples, 2 alarm thresholds

K:-200...+1300°C
J:-13...+900°C
T:-200...+350°C

1

0.5 K
(1 °F)

1 s to
12 h

USB

stand-alone

EL-USB-TC-LCD
Datalogger for thermocouples with display and 2 alarm thresholds

K:-200...+1300°C
J:-13...+900°C
T:-200...+400°C

1

0.5 K
(1 °F)

1 s to
12 h

USB

stand-alone

Display DataPad for Easylog-DataloggerserEL-DataPad
Portable Viewer for EL-USB Temperature Data Loggers

Compatible data loggers:
EL-USB-1, EL-USB-1-LCD, EL-USB-1-PRO,
EL-USB-2, EL-USB-2+, EL-USB-2-LCD, EL-USB-2-LCD+,
EL-USB-TC, EL-USB-TC-LCD

Data Acquisition Softwares
Symboldescription: show Datasheet add to Notepad Productdetails as PDF

ModelHost InstrumentSample RateLanguageOperating System
WinDaq/Pro
Software for measurement equipment configuration and data recording on PC with the maximum sample rate of the hardware

DI-720
DI-722
DI-730

depending on hardware, the same for each channel

English

Windows® 2000
Windows® XP
Windows Vista®
(32 bit)

WinDaq/Pro+
Software for measurement equipment configuration and to record the data on PC with the maximum sample rate of the hardware

DI-720
DI-722
DI-730

depending on hardware, each channel individually

English

Windows® 2000
Windows® XP
Windows Vista®
(32 bit)

WinDaq/HS
Software for measurement equipment configuration and data recording on PC with the maximum sample rate of the hardware

DI-14x
DI-15x
DI-71x

depending on hardware, the same for each channel

English

Windows® 2000
Windows® XP
Windows Vista®
(32 bit)

WinDaq/XL
Plug-in for real-time transmission of the data to Microsoft® Excel®

DI-19x
DI-14x/DI-15x
DI-71x
DI-72x/DI-73x

-

English

Windows® 2000
Windows® XP
Windows Vista®
(32 bit)

midiLogger Software
Free software for configuration, recording and analysis of the data, export to ASCII,Excel® and FlexPro 7

GL200
GL800

depending on hardware

German

Windows® 2000
Windows® XP
Windows Vista®
(32 bit)

EL-WIN-USB SoftwareEL-WIN-USB
Free software for configuration, recording and analysis of the measurement data of EasyLog data loggers

EL-USB data loggers

depending on hardware

English

Vibromatrix® Vibration Measuring Systems
Symboldescription: show Datasheet add to Notepad Productdetails as PDF

ModelFeatures
InnoBeamer® LX2
USB data acquisition device for IEPE vibration sensors, easy to use system for PC-based vibration measurement and analysis

Frequency range: 0.1 ... 3200 Hz
Supply: via USB
Interface: USB 1.1 and higher, compatible up to Windows 7
Housing: in-line

InnoBeamer® X2
USB data acquisition device for IEPE vibration sensors, easy to use system for PC-based vibration measurement and analysis

Frequency range: 0.1 ... 40000 Hz
Supply: via USB
Interface: USB 2.0 and higher, compatible up to Windows 7
Housing: in-line

InnoMeter®
When vibrations are measured as significant parameters, the InnoMeters are applied.

The InnoMeters in Standard and in Pro Version are highly universal measuring instruments for vibration parameters.They can be adapted to parameters from numerous vibration standards. Measurands: acceleration, velocity, displacement

InnoPlotter®
When vibration parameters are measured and controlled for a longer time, the InnoPlotters are suitable

The InnoPlotters in Standard and in Pro Version are universal digital strip chart recorders for vibration parameters.The Pro Version includes two integrators and is consequently able to process not only vibration acceleration, but alsovibration velocity and displacement.

InnoLogger®
For the monitoring of vibration parameters and their logging for later analysis

Rotating parts in drives, gears, pumps, fans and many other technical products cause perturbing vibrations.Impulse-like loads, e.g. from a vibratory pile driver in the construction-field, generate problems as well.

InnoScope®
The InnoScopes allow the signals‘ shape analysis of fast vibration and shock processes in time domain.These processes are acquired and measured with high resolution and can be exported for documentation or postprocessing.

Another field of application is the determination of natural frequencies. The measurement object is stimulated impulse-like,the InnoScope triggers the event and displays the time course of the signal. A coupled InnoAnalyzer analyzes the triggered timesignal and displays it in the frequency domain simultaneously. Natural frequencies can be read off at once.

InnoAnalyzer®
For the frequency analysis of vibrations

Rotating parts in drives, gears, pumps, fans and many other technical products cause perturbing vibrations. Often numerousparts with different rotation speed cause mechanical vibrations so that a superposition of frequencies is generated.

InnoAnalyzer® Speed
Different rotation speeds cause different vibrations since the measurement objects develop or donot develop resonant behaviour at certain rotation speeds.

These differences become obviously when measuring run-up or coast-down curves. A rotor changes its rotation speed and excitesdifferent frequencies of the system. The InnoAnalyzers Speed measure the vibration level at the rotation speed or a multipleand graphically indicate magnitude and phase at the respective rotation speed.

InnoBalancer®
The InnoBalancers are used for the reduction of vibrations.

The InnoBalancers allow a purposeful reduction of the vibration by balancing.Both discoidal and longish rotors can be balanced systematically and fast.

InnoMeter® HVM 5349:2001
Human hand-arm vibration measurement acc. to EN ISO 5349:2001 and EC Directive 2002/44/EC

If hand held machines or workpieces transmit strong vibrations to the operator, a decreased performance and even diseases in blood vessels, nerves, bones,joints, muscles or the connective tissue might develop. For this reason, divers guidelines stipulate measurements acc. to EN ISO 5349, which determinesthe impact on the human hand-arm-system.

InnoMeter® HVM 2631:1997
Human whole-body vibration measurement acc. to EN ISO2631:1997 and EC Directive 2002/44/EC

If strong vibrations are transmitted to human beings, a decreased performance and even diseases in blood vessels, nerves, bones,joints, muscles or connective tissue might develop. For this reason, divers guidelines stipulate measurements acc. to ISO2631,which assesses the vibration impact on human beings.

InnoMeter® HVM 6954:2001
Vibration measurement on ships

On board passenger and merchant vessels vibrations can occur, which may negatively interfere with the work of the crew or which maydiminish the comfort of passengers and crew. In order to assess complaints or to prevent them, measurements acc. to DIN ISO 6954:2001are suitable, since they allow the evaluation of the vibration severity with regard to habitability on board ships.

InnoMeter® 4150-3
The InnoMeter 4150-3 was developed for the measurement of vibrations on buildings acc. to the German standard DIN 4150-3.

Vibrations from heavy building activities, traffic, machine operation or also detonations affect existing building stock. The InnoMeter4150-3 measures these vibrations, valuates acc. to the standard immediately and can inform about the vibrations occured at any time.

InnoMeter® 3834
The InnoMeter 3834 was developed for the measurement of vibrations on wind energy systems acc. to German standard VDI 3834

This instrument allows the measurement and analysis of vibrations on both building constructions (like tower and generator house)and machinery components, like rotor, gear and generator.