? Explanation
  • add to Notepad
  • HTML-Datasheet
  • no Datasheet available
  • Productdetails as PDF

Potentiometric Position Sensors
Symboldescription: show Datasheet add to Notepad Productdetails as PDF

ModelMeasurement RangeOutputAccuracySize
Potentiometer 8FLP10A8FLP10A
Potentiometric position sensor, conductive plastic

11 mm

1 kOhm to
20 kOhm

1 %
to
2 %

Case:
8.2 x 7.3 x 32 mm
Shaft diameter 2 mm

Potentiometer 13FLP13FLP
Potentiometric position sensor, conductive plastic

12 mm to
100 mm

500 Ohm to
20 kOhm

0.3 %
to
2 %

Case:
13 x 11 x 38...127 mm
Shaft diameter 3.175 mm

Potentiometer 30FLP30FLP
Potentiometric linear displacement sensor, conductive plastic

100 mm to
1000 mm

1 kOhm to
500 kOhm

0.05 %
to
0.5 %

Case:
35 x 32 x 170...1070 mm
Shaft diameter approx. 10mm

Potentiometer 40FLP40FLP
Potentiometric linear displacement sensor, conductive plastic

200 mm to
1000 mm

2 kOhm to
500 kOhm

0.05 %
to
0.5 %

Case:
47 x 40 x 360...1160 mm

Potentiometer CFLCFL
Potentiometric displacement sensor

200 mm to
1000 mm

2 kOhm to
500 kOhm

0.05 %
to
0.5 %

Case:
10 x 20 x 250...1050 mm

Potentiometer FDPL2SFDPL2S
Potentiometric position sensor, conductive plastic

50 mm to
750 mm

2 kOhm to
20 kOhm

0.075 %
to
0.1 %

Case:
31 x 31 x 127...827 mm
Shaft diameter 6 mm

Potentiometer FDPLFDPLS-V | FDPL2S-V | FDPL231-V
Potentiometric position sensor, conductive plastic

50 mm to
950 mm

0 ... 10 V

Case:
31 x 31 x 190...1090 mm

Potentiometer FDP60FDP60
Draw-wire potentiometer

100 mm to
1500 mm

1 kOhm
0 ... 10 V
4 ... 20 mA

0.1 %
to
0.5 %

60 x 76.5 x 129 mm
(Model P)

LVDT Transducers
Symboldescription: show Datasheet add to Notepad Productdetails as PDF

ModelMeasurement RangeSpring-loadedAccuracyOutput [Supply Voltage]
LVDT DC-ECDC-EC
Schaevitz™ general purpose LVDT

±1.27 mm
to
±254 mm

no

0.25 %

±10 V [±15 VDC]

LVDT DC-SEDC-SE
Schaevitz™ general purpose LVDT

0 ... 2.5 mm
to
0 ... 150 mm

no

0.25 %

0 ... 5 V [8.5 ... 28 VDC]
1 ... 6 V [8.5 ... 28 VDC]

LVDT EE
Schaevitz™ economical LVDT

±2.54 mm
to
±50.8 mm

no

0.5 %
(E-2000: 1.0 %)

18 ... 95 mV/V per mm
[3 Vrms]

LVDT GC-485GC-485
Schaevitz™ ultra precision digital I/O gage head

±1.27 mm
to
±25.4 mm

yes

0.1 %

RS-485 [8.5 ... 30 VDC]

Gage Head GCAGCA
Schaevitz™ precision gage heads, spring-loaded design

±1.27 mm
to
±50.8 mm

yes

0.25 %

13 ... 165 mV/V per mm
[3 V rms]

Gage Head GCDGCD
Schaevitz™ precision gage heads, spring-loaded design

±1.27 mm
to
±50.8 mm

yes

0.25 %

0.2 ... 8 V/mm [±15 VDC]

LVDT GCD-SEGCD-SE
Schaevitz™ precision gage heads, spring-loaded design

0 ... 2.54 mm
to
0 ... 50.8 mm

yes

0.25 %

0 ... 5 V [8.5 ... 28 VDC]
1 ... 6 V [8.5 ... 28 VDC]

LVDT GCTGCT
Gage head transmitter

0 ... 6.35 mm
to
0 ... 50.8 mm

yes

0.5 %

4 ... 20 mA [10.5 ... 28 VDC]

LVDT HC485HC485
Schaevitz™ RS-485 multi-drop displacement sensor

±1.25 mm
to
±75 mm

no

0.25 %
or
0.05 %

RS-485 [8.5 ... 30 VDC]

LVDT HCAHCA | HCA-RA
Schaevitz™ hermetically sealed LVDT

±1.27 mm
to
±254 mm

no

0.25 %

5 ... 165 mV/V per mm
[3 Vrms]

LVDT HCDHCD
Schaevitz™ hermetically sealed LVDT

±1.25 mm
to
±250 mm

no

0.25 %

±10 V [±15 VDC]

LVDT HCT420HCT 420-xxx-IS
Intrisically safe 2-wire 4...20 mA position transmitter

0 ... 6.35 mm
to
0 ... 254 mm

no

0.5 %
or
1.0 %

4 ... 20 mA 2L [13 ... 28 VDC]

LVDT HRHR
Schaevitz™ general purpose LVDT

±1.27 mm
to
±254 mm

no

0.25 %

2.8 ... 228 mV/V per mm
[3 Vrms]

LVDT LBBLBB
High precision gage heads

±0.02" to
±0.2"
(±0.5 mm to
±5 mm)

yes

0.2 %

200 ... 280 mV/V per mm
[3,5 Vrms]
170 mV/V per mm
[5 Vrms]

LVDT M12M12
Schaevitz™ LVDT

±10 mm
to
±100 mm

no

0.25 %

7.1 ... 42 mV/V per mm
[3 Vrms]

LVDT M12SXM12SX | M12S
Special LVDT for steel mill applications

±20 mm
to
±50 mm

no

0.2 %

9 ... 20 mV/V per mm
[2.2 Vrms]

LVDT MHRMHR
Schaevitz™ miniature LVDT

±0.13 mm
to
±50.8 mm

no

0.25 %

19 ... 343 mV/V per mm
[3 Vrms]

LVDT MPMP
Schaevitz™ LVDT

±12.7 mm
to
±254 mm

no

0.25 %

2.8 ... 28 mV/V per mm
[3 Vrms]

LVDT PCA-116PCA-116
Schaevitz™ economy gage heads

±2.5 mm
to
±7.6 mm

yes

0.5 %

47 ... 94 mV/V per mm
[3 Vrms]

LVDT PCA-375PCA-375
Schaevitz™ gage heads

±2.54 mm
to
±25.4 mm

yes

0.5 %

30 ... 110 mV/V per mm
[3 Vrms]

LVDT XS-BXS-B | XS-BG
Schaevitz™ subminiature LVDT

±2.54 mm
±6.35 mm

no

0.5 % (XS-B)
0.2 % (XS-BG)

XS-B:
55 ... 59 mV/V per mm [1 Vrms]
XS-BG:
207 mV/V per mm [3.5 Vrms]

LVDT XS-CXS-C
Schaevitz™ high pressure sealed LVDT

±6.35 mm
to
±25.4 mm

no

0.25 %

31.5 ... 66.9 mV/V per mm
[3 Vrms]

LVDT XS-DXS-D
Schaevitz™ long stroke-to-body length LVDT

±25.4 mm
to
±254 mm

no

2.0 %

2 ... 11 mV/V per mm
[3 Vrms]

Inductive Position Sensors
Symboldescription: show Datasheet add to Notepad Productdetails as PDF

ModelMeasurement RangeSpring-loadedAccuracyOutput [Supply Voltage]
Position Sensor LCITLCIT
Schaevitz™ linear position sensor

±3 mm
to
±50 mm

no

0.25 %

0.5 ... 4.5 V [7 ... 36 VDC]

Position Sensor P100LIPS P100
Cylinder - linear position sensor

0 ... 20 mm
to
0 ... 600 mm

no

0.25 %
to
0.5 %

0.5 ... 4.5 V ratiometric [5 VDC]
0.5 ... 4.5 V [9 ... 28 VDC]
±5 V [±9 ... 28 VDC]
0.5 ... 9.5 V [13 ... 28 VDC]
±10 V [±13.5 ... 28 VDC]
4 ... 20 mA 2L [18 ... 28 VDC]
4 ... 20 mA 3L [13 ... 28 VDC]

Position Sensor P101LIPS P101
Stand alone linear inductive position sensor

0 ... 50 mm
to
0 ... 600 mm

no

0.25 %
to
0.5 %

0.5 ... 4.5 V ratiometric [5 VDC]
0.5 ... 4.5 V [9 ... 28 VDC]
±5 V [±9 ... 28 VDC]
0.5 ... 9.5 V [13 ... 28 VDC]
±10 V [±13.5 ... 28 VDC]
4 ... 20 mA 2L [18 ... 28 VDC]
4 ... 20 mA 3L [13 ... 28 VDC]

Position Sensor P103LIPS P103
Short stroke linear position sensor

0 ... 10 mm
to
0 ... 50 mm

yes

0.25 %

0.5 ... 4.5 V ratiometric [5 VDC]
0.5 ... 4.5 V [9 ... 28 VDC]
±5 V [±9 ... 28 VDC]
0.5 ... 9.5 V [13 ... 28 VDC]
±10 V [±13.5 ... 28 VDC]
4 ... 20 mA 2L [18 ... 28 VDC]
4 ... 20 mA 3L [13 ... 28 VDC]

Position Sensor P106LIPS P106
Linear inductive position sensor for hydraulic cylinders

0 ... 20 mm
to
0 ... 600 mm

no

0.25 %
to
0.5 %

0.5 ... 4.5 V ratiometric [5 VDC]
0.5 ... 4.5 V [9 ... 28 VDC]
±5 V [±9 ... 28 VDC]
0.5 ... 9.5 V [13 ... 28 VDC]
±10 V [±13.5 ... 28 VDC]
4 ... 20 mA 2L [18 ... 28 VDC]
4 ... 20 mA 3L [13 ... 28 VDC]

Position Sensor P111LIPS P111
Rugged linear position sensor

0 ... 50 mm
to
0 ... 600 mm

no

0.25 %
to
0.5 %

0.5 ... 4.5 V ratiometric [5 VDC]
0.5 ... 4.5 V [9 ... 28 VDC]
±5 V [±9 ... 28 VDC]
0.5 ... 9.5 V [13 ... 28 VDC]
±10 V [±13.5 ... 28 VDC]
4 ... 20 mA 2L [18 ... 28 VDC]
4 ... 20 mA 3L [13 ... 28 VDC]

Position Sensor P112LIPS P112
Gauge head position sensor

0 ... 10 mm
to
0 ... 50 mm

yes

0.25 %

0.5 ... 4.5 V ratiometric [5 VDC]

Position Sensor P117LIPS P117
Slim-line linear position sensor

0 ... 10 mm
to
0 ... 300 mm

no

0.25 %

0.5 ... 4.5 V ratiometric [5 VDC]
0.5 ... 4.5 V [9 ... 28 VDC]
0.5 ... 9.5 V [13 ... 28 VDC]

Intrinsically-Safe Inductive Position Sensors
Symboldescription: show Datasheet add to Notepad Productdetails as PDF

ModelMeasurement RangeSpring-loadedAccuracyOutput [Supply Voltage]
Intrinsically-safe Position Sensor X100LIPS X100
Cylinder - linear position sensor, intrinsically safe for hazardous gas/vapour atmospheres

0 ... 20 mm
to
0 ... 600 mm

no

0.25 %
to
0.5 %

via X005

Intrinsically-safe Position Sensor X101LIPS X101
Stand-alone linear position sensor, intrinsically safe for hazardous gas/vapour atmospheres

0 ... 50 mm
to
0 ... 600 mm

no

0.25 %
to
0.5 %

via X005

Intrinsically-safe Position Sensor X103LIPS X103
Short stroke linear position sensor, intrinsically safe for hazardous gas/vapour atmospheres

0 ... 10 mm
to
0 ... 50 mm

yes

0.25 %

via X005

Intrinsically-safe Position Sensor X106LIPS X106
Cylinder sensor with external electronics, intrinsically safe for hazardous gas/vapour atmospheres

0 ... 20 mm
to
0 ... 600 mm

no

0.25 %
to
0.5 %

via X005

Intrinsically-safe Position Sensor X111LIPS X111
Ruged stand-alone linear position sensor, intrinsically safe for hazardous gas/vapour atmospheres

0 ... 50 mm to
0 ... 600 mm

no

0.25 %
to
0.5 %

via X005

Intrinsically-safe Position Sensor X112LIPS X112
Gauge head position sensor, intrinsically safe for hazardous gas/vapour atmospheres

0 ... 10 mm
to
0 ... 50 mm

yes

0.25 %

via X005

Intrinsically-safe Position Sensor X117LIPS X117
Slim-line linear position sensor, intrinsically safe for hazardous gas/vapour atmospheres

0 ... 10 mm
to
0 ... 300 mm

no

0.25 %

via X005

Galvanic Isolation Amplifier X005X005
Galvanic Isolation Amplifier

for use with intrinsically safe sensor series LIPS and RIPS
ATEX- and IECEx approval
sensor supply 5 V

0.5 ... 9.5 V [12 ... 30 VDC]
9.5 ... 0.5 V [12 ... 30 VDC]
4 ... 20 mA [12 ... 30 VDC]
20 ... 4 mA [12 ... 30 VDC]

Non-contacting Eddie Current Sensors and Measuring Systems
Symboldescription: show Datasheet add to Notepad Productdetails as PDF

ModelMeasurement RangeAccuracyOutput [Supply Voltage]
Eddie current sensors Eddie current sensors
for non-contact position sensing

0.5 mm
to
60 mm

depending on measuring system

depending on measuring system

DIT-5200 - non-contact position sensingDIT-5200
Differential impedance transducer

±0.25 mm
to
±1.91 mm

0.1 %
to
1 %

±10 V [±15 VDC]

KD-2306 - non-contact position sensingKD-2306
Single channel multi-purpose non-contact displacement sensing system

0 ... 0.5 mm
to
0 ... 60 mm

sensor dependent

0 ... 10 V [15 ... 30 VDC]
or
0 ... 5 V, ±5 V, 4 ... 20 mA

KD-2446 Position Measuring SystemKD-2446
High-precision proximity measuring system

0 ... 0.5 mm
to
0 ... 15 mm

see datasheet

0 ... 10 V [12 VDC]
0 ... 22 V [24 VDC]

KD-5100 - non-contact position sensingKD-5100
Differential measuring system

±0.9 mm
and
±1.9 mm

0.1 %
to
0.5 %

±10 V [±15 VDC]

KDM-8200 - non-contact position sensingKDM-8200
Modular high precision displacement measuring system

0 ... 0.5 mm
to
0 ... 4 mm

0.5 %

±5 V [±15 VDC]

ThreadChecker - non-contact position sensing ThreadChecker™
Non-contact application-specific sensor designed to check thread presence

Threads M4 to M14

NPN switching output
and
0 ... 10 V [15 ... 30 VDC]