Linear-motion Potentiometers
  Model
Measurement
Range
Resistance
NL
Dimensions
Data Sheet
13FLP
Linear-motion Potentiometer,
Conductive Plastic
12 mm to 100 mm
500 Ohm to
20 kOhm
0,3%
to
2%
Case:
13 x 11 x 38...127 mm
Diameter Shaft 3,175 mm
PDF: Potentiometer 13FLP
HTML: Potentiometer 13FLP
8FLP10A
Linear-motion Potentiometer,
Conductive Plastic
11 mm
1 kOhm to
20 kOhm
1%
to
2%
Case:
8,2 x 7,3 x 32 mm
Diameter Shaft 2 mm
PDF: Potentiometer 8FLP10A
HTML: Potentiometer 8FLP10A
PL2S
Linear-motion Potentiometer,
Conductive Plastic
50 mm to 500 mm
2 kOhm to
20 kOhm
0,075%
to
0,1%
Case:
31 x 31 x 127...577 mm
Diameter Shaft 6 mm
PDF: Potentiometer PL2S
HTML: Potentiometer PL2S

Linear-motion Potentiometers  ||   LVDT Transducers  ||   Inductive LVDTs  ||   Intrinsically Safe LVDTs  ||   Displays and Measuring Amplifiers for LVDTs and RVDTs  ||   Non-contacting Eddie Current Sensors and Measuring Systems

LVDT Transducers
  Model
Measurement
Range
Spring Load Version
NL
Output
mV/V
20mA
5/10V
digit.
Data Sheet
DC-EC
General Purpose LVDT
±0,125 mm to
±250 mm
no
0,25%
---
---
std.
---
PDF: LVDT DC-EC
HTML: LVDT DC-EC
DC-SE
General Purpose LVDT
0...2,5 mm to
0...150 mm
no
0,25%
---
---
std.
---
PDF: LVDT DC-SE
HTML: LVDT DC-SE
E
Schaevitz™
Economical LVDT
±2,54 mm to
±50,8 mm
no
0,5%
or
1,0%
std.
---
---
---
PDF: LVDT E
HTML: LVDT E
GC-485
Ultra Precision Digital I/O Gage Head
±1,27 mm to
±25,4 mm
yes
0,05%
---
---
---
std.
PDF: LVDT GC-485
HTML: LVDT GC-485
GCA :: GCD
Precision Gage Heads, Spring-Loaded Design
±1,27 mm to
±50,8 mm
yes
0,25%
std.
---
std.
---
PDF: LVDT GCA :: GCD
HTML: LVDT GCA :: GCD
GCD-SE
Precision Gage Heads, Spring-Loaded Design
0...2,54 mm to
0...50,8 mm
yes
0,25%
---
---
std.
---
PDF: LVDT GCD-SE
HTML: LVDT GCD-SE
GCT
Gage Head Transmitter
0...6,35 mm to
0...50,8 mm
yes
0,5%
---
std.
---
---
PDF: LVDT GCT
HTML: LVDT GCT
HC485
Schaevitz™ RS-485 Multi-Drop Displacement Sensor
±1,27 mm to
±75 mm
no
0,25%
---
---
---
std.
PDF: LVDT HC485
HTML: LVDT HC485
HCA
Schaevitz™ Hermetically Sealed LVDT
±1,27 mm to
±254 mm
no
0,2%
bis
1,0%
std.
---
---
---
PDF: LVDT HCA
HTML: LVDT HCA
HCD
Schaevitz™ Hermetically Sealed LVDT
±1,25 mm to
±250 mm
no
0,25%
---
---
std.
---
PDF: LVDT HCD
HTML: LVDT HCD
HCT 420-xxx-IS
Intrinsically Safe 2-wire 4-20 mA Position Transmitter
0...6,35 mm to
0...254 mm
no
0,5%
bzw.
1,0%
---
std.
---
---
PDF: LVDT HCT-IS
HTML: LVDT HCT-IS
HR
General Purpose LVDT
±1,27 mm
to
±254 mm
no
0,1%
to
1,3%
std.
---
---
---
PDF: LVDT HR
HTML: LVDT HR
M12
Schaevitz™ LVDT
±5 mm to
±150 mm
no
0,25%
std.
---
---
---
PDF: LVDT M12
HTML: LVDT M12
M12SX-30-25-150A-0.1 :: M12S-xx-xx-150A-0.1
Special LVDTs for steel mill applications
±20 mm to
±50 mm
no
0,2 %
std.
---
---
---
PDF: LVDT M12S
HTML: LVDT M12S
MHR
Miniature LVDT
±0,13 mm to
±25,4 mm
no
0,1%
bis
0,75%
std.
---
---
---
PDF: LVDT MHR
HTML: LVDT MHR
PCA 116
Economy Gage Heads
±;2,5 mm to
±7,5 mm
yes
0,5%
std.
---
---
---
PDF: LVDT PCA 116
HTML: LVDT PCA 116
XS-B
Schaevitz™ Sub-Miniature LVDT
±2,4 mm
±6,4 mm
no
0,2%
to
0,5%*1
std.
---
---
---
PDF: LVDT XS-B
HTML: LVDT XS-B
XS-C
High-Pressure Sealed LVDT
±6,35 mm to
±25,4 mm
no
0,2%
to
0,25%*1
std.
---
---
---
PDF: LVDT XS-C
HTML: LVDT XS-C
XS-D
Long Stroke-to-Body Length LVDT
±25,4 mm to
±254 mm
no
2,0%*1
std.
---
---
---
PDF: LVDT XS-D
HTML: LVDT XS-D

Linear-motion Potentiometers  ||   LVDT Transducers  ||   Inductive LVDTs  ||   Intrinsically Safe LVDTs  ||   Displays and Measuring Amplifiers for LVDTs and RVDTs  ||   Non-contacting Eddie Current Sensors and Measuring Systems

Inductive LVDTs
  Model
Measurement
Range
Spring Load Version
NL
Output
mV/V
20mA
5/10V
digit.
Data Sheet
LCIT
Linear Position Sensor
±3 mm to ±75 mm
no
0,25%
---
---
std.
---
PDF: Position Sensor LCIT
HTML: Position Sensor LCIT
LIPS P100
Cylinder - Linear Position Sensor
0...20 mm to
0...600 mm
no
0,25%
to
0,5%
---
opt.
std.
---
PDF: Position Sensor P100
LIPS P101
Stand Alone Linear Inductive Position Sensor
0...50 to
0...600 mm
no
0,25%
to
0,5%
---
opt.
std.
---
PDF: Position Sensor P101
LIPS P103
Short Stroke Linear Position Senso
0...10 mm to
0...50 mm
yes
0,5%
---
opt.
std.
---
PDF: Position Sensor P103
LIPS P106
Linear Inductive Position Sensor for Hydraulic Cylinders
0...20 mm to
0...600 mm
no
0,25%
to
0,5%
---
opt.
std.
---
PDF: Position Sensor P106
LIPS P111
Rugged Linear Position Sensor
0...50 mm to
0...600 mm
no
0,25%
to
0,5%
---
opt.
std.
---
PDF: Position Sensor P111
LIPS P112
Gauge Head Position Sensor
0...10 mm to
0...50 mm
Yes
0,25%
---
opt.
std.
---
PDF: Position Sensor P112
LIPS P113
Slim-Line Linear Position Sensor
0...10 mm to
0...300 mm
no
0,25%
---
opt.
std.
---
PDF: Position Sensor P113
HTML: Position Sensor P113

Linear-motion Potentiometers  ||   LVDT Transducers  ||   Inductive LVDTs  ||   Intrinsically Safe LVDTs  ||   Displays and Measuring Amplifiers for LVDTs and RVDTs  ||   Non-contacting Eddie Current Sensors and Measuring Systems

Intrinsically Safe Inductive Position Sensors
  Model
Measurement Range
Spring Load Version
NL
Output
mV/V
20mA
5/10V
digit.
Data Sheet
LIPS X100
Cylinder - Linear Position Sensor, Intrinsically Safe for Gas
0...20 mm to
0...600 mm
no
0,25%
to
0,5%
---
std.
std.
---
from Safety Barrier
PDF: Position Transducer X100
HTML: Position Transducer X100
LIPS X101
Stand-Alone Linear Position Sensor, Intrinsically Safe for Gas
0...50 mm to
0...600 mm
no
0,25%
to
0,5%
---
std.*
std.*
---
PDF: Position Transducer X101
HTML: Position Transducer X101
LIPS X103
Short Stroke Linear Position Sensor, Intrinsically Safe for Gas
0...10 mm to
0...50 mm
yes
0,5%
---
std.*
std.*
---
PDF: Position Transducer X103
LIPS X106
Cylinder Sensor with External Electronics, Intrinsically Safe for Gas
0...20 mm to
0...600 mm
no
0,25%
to
0,5%
---
std.*
std.*
---
PDF: Position Transducer X106
HTML: Position Transducer X106
LIPS X111
Rugged Stand-Alone Linear Position Sensor, Intrinsically Safe for Gas
0...50 mm to
0...600 mm
no
0,25%
to
0,5%
---
std.*
std.*
---
PDF: Position Transducer X111
HTML: Position Transducer X111
LIPS X112
Gauge Head Position Sensor, Intrinsically Safe for Gas
0...10 mm to
0...50 mm
yes
0,25%
---
std.*
std.*
---
PDF: Position Transducer X112
LIPS X113
Slim-lime Linear Postion Sensor, Intrinsically Safe for Gas
0...10 mm to
0...300 mm
no
0,25%
---
std.*
std.*
---
PDF: Position Transducer X113
HTML: Position Transducer X113
BX002 :: BX003
Intrinsically Safe Sensor Barrier for LIPS Sensors
 
 
 
---
std.
std.
---
PDF: Safety Barrier BX002/3
HTML: Safety Barrier BX002/03
*from safety barrier BX002 or BX003

Linear-motion Potentiometers  ||   LVDT Transducers  ||   Inductive LVDTs  ||   Intrinsically Safe LVDTs  ||   Displays and Measuring Amplifiers for LVDTs and RVDTs  ||   Non-contacting Eddie Current Sensors and Measuring Systems

Displays and Measuring Amplifiers for LVDTs and RVDTs
  Model
Supply
Voltage
Output
Configuration
Dimensions
W x H x D [mm]
Data Sheet
MC-KP-12E/24E-xxx
Single channel LVDT/RVDT amplifier
10 ... 18 VDC
18 ... 30 VDC
0 ... 10 V
±10 V
4 ... 20 mA
Plastic enclosure for DIN top hat rail mounting
IP20
23 x 99 x 115
PDF: Amplifier MC-KP
HTML: Amplifier MC-KP
MC-IP-12E/24E-xxx
Single channel LVDT/RVDT amplifier in aluminium IP enclosure

10 ... 18 VDC
18 ... 30 VDC
0 ... 10 V
±10 V
4 ... 20 mA
EMC aluminium
die-cast enclosure
IP65
175 x 57 x 80
PDF: Amplifier MC-IP
HTML: Amplifier MC-IP
MC-1K/2K-KA/EK-15B-xxx
Single or dual channel LVDT/RVDT amplifier
±15 VDC regulated
0 ... 10 V
±10 V
±5 V
Euroboard /
plug-in unit with EMC front panel
3HE / 7 TE
depth euroboard 160
PDF: Amplifier MC-1K
HTML: Amplifier MC-1K
MP2000
Dual channel LVDT readout / controller
100 to 240 VAC/
47 ... 63 Hz
0 ... 10 V
±5 V
RS232
¼ DIN panel enclosure
opt. desktop unit
99 x 99 x 172,7
PDF:
ATA-2001
LVDT amplifier, analog conditioner with digital calibration
115 VAC / 50 ... 400 Hz
220 VAC / 50 ... 400 Hz
0 ... 10 V
±10 V
4 ... 20 mA
1/8 DIN panel enclosure
opt. 19"rack mounting
96 x 48 x 265,9
PDF:
MCH-P :: MCH-P5
MCH hybrid electronics for inductive transducers
±15 VDC
±10 VDC
Hybrid board
40,6 x 17,2 (24,2)
x 3
PDF:

Linear-motion Potentiometers  ||   LVDT Transducers  ||   Inductive LVDTs  ||   Intrinsically Safe LVDTs  ||   Displays and Measuring Amplifiers for LVDTs and RVDTs  ||   Non-contacting Eddie Current Sensors and Measuring Systems

Non-contacting Eddie Current Sensors and Measuring Systems
  Model
Measurement
Range
NL
Output
mV/V
20mA
5/10V
digit.
Data Sheet
Sensors
0,05 mm to
60 mm
 
---
---
---
---
PDF: Eddie Current Sensor Sensors
HTML: Eddie Current Sensor Sensors
GageProx™
Fixed-gain linear inductive analog proximity sensors developed for metalforming
0...1,25 mm to
0...3 mm
1%
---
---
std.
---
PDF: Eddie Current Sensor GageProx
HTML: Eddie Current Sensor GageProx
KD-2306
Non-Contact Position Measuring System
0...0,5 mm to
0...50 mm
0,5%
to
1%
---
std.
std.
---
PDF: Eddie Current Sensor KD-2306
KD-2440
High-precision Proximity Measuring System
 
 
---
---
std.
---
PDF: Eddie Current Sensor KD-2440
HTML: Eddie Current Sensor KD-2440
ThreadChecker™
Non-contact application-specific sensors designed to check thread presence
Threads M4 to M14
 
---
---
std.
---
PDF: Eddie Current Sensor ThreadCheck
HTML: Eddie Current Sensor ThreadCheck
Pressure Sensors - Pressure Transducers || Force Transducers - Load Cells || Torque Transducers || Displacement Transducers - Position Measuring Systems || Rotary Angle Transducers || Inclinometers - Tilt Measuring Systems || Accelerometers || Vibration Sensors || Signal Conditioning || Data Acquisition - Data Loggers