| MEASUREMENT and SENSOR TECHNOLOGY |
![]() |
POSITION MEASUREMENT - SENSORS - TRANSDUCERS - TRANSMITTERS
|
COMPANY INFORMATION |
|
|
Linear-motion Potentiometers |
||||||
|---|---|---|---|---|---|---|
| Model | Measurement Range |
Resistance |
Dimensions |
Data Sheet | ||
![]() |
13FLP Linear-motion Potentiometer, Conductive Plastic |
12 mm to 100 mm |
500 Ohm to 20 kOhm |
0,3% to 2% |
Case:
13 x 11 x 38...127 mm Diameter Shaft 3,175 mm | |
![]() |
8FLP10A Linear-motion Potentiometer, Conductive Plastic |
11 mm |
1 kOhm to 20 kOhm |
1% to 2% |
Case:
8,2 x 7,3 x 32 mm Diameter Shaft 2 mm | |
![]() |
PL2S Linear-motion Potentiometer, Conductive Plastic |
50 mm to 500 mm |
2 kOhm to 20 kOhm |
0,075% to 0,1% |
Case: 31 x 31 x 127...577 mm Diameter Shaft 6 mm |
|
|
|
LVDT Transducers |
||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Model | Measurement Range |
Spring Load Version |
|
Data Sheet | ||||||||||
![]() |
DC-EC General Purpose LVDT |
±0,125 mm to ±250 mm |
no |
0,25% |
|
|||||||||
![]() |
DC-SE General Purpose LVDT |
0...2,5 mm to 0...150 mm |
no |
0,25% |
|
PDF: LVDT DC-SE HTML: LVDT DC-SE |
||||||||
![]() |
E Schaevitz™ Economical LVDT |
±2,54 mm to ±50,8 mm |
no |
0,5% or 1,0% |
|
|||||||||
![]() |
GC-485 Ultra Precision Digital I/O Gage Head |
±1,27 mm to ±25,4 mm |
yes |
0,05% |
|
|||||||||
![]() |
GCA :: GCD Precision Gage Heads, Spring-Loaded Design |
±1,27 mm to ±50,8 mm |
yes |
0,25% |
|
|||||||||
![]() |
GCD-SE Precision Gage Heads, Spring-Loaded Design |
0...2,54 mm to 0...50,8 mm |
yes |
0,25% |
|
|||||||||
![]() |
GCT Gage Head Transmitter |
0...6,35 mm to 0...50,8 mm |
yes |
0,5% |
|
|||||||||
![]() |
HC485 Schaevitz™ RS-485 Multi-Drop Displacement Sensor |
±1,27 mm to ±75 mm |
no |
0,25% |
|
|||||||||
![]() |
HCA Schaevitz™ Hermetically Sealed LVDT |
±1,27 mm to ±254 mm |
no |
0,2% bis 1,0% |
|
|||||||||
![]() |
HCD Schaevitz™ Hermetically Sealed LVDT |
±1,25 mm to ±250 mm |
no |
0,25% |
|
|||||||||
![]() |
HCT 420-xxx-IS Intrinsically Safe 2-wire 4-20 mA Position Transmitter |
0...6,35 mm to 0...254 mm |
no |
0,5% bzw. 1,0% |
|
|||||||||
![]() |
HR General Purpose LVDT |
±1,27 mm to ±254 mm |
no |
0,1% to 1,3% |
|
|||||||||
| M12 Schaevitz™ LVDT |
±5 mm to ±150 mm |
no |
0,25% |
|
||||||||||
| M12SX-30-25-150A-0.1 :: M12S-xx-xx-150A-0.1 Special LVDTs for steel mill applications |
±20 mm to ±50 mm |
no |
0,2 % |
|
||||||||||
![]() |
MHR Miniature LVDT |
±0,13 mm to ±25,4 mm |
no |
0,1% bis 0,75% |
|
|||||||||
![]() |
PCA 116 Economy Gage Heads |
±;2,5 mm to ±7,5 mm |
yes |
0,5% |
|
|||||||||
![]() |
XS-B Schaevitz™ Sub-Miniature LVDT |
±2,4 mm ±6,4 mm |
no |
0,2% to 0,5%*1 |
|
|||||||||
![]() |
XS-C High-Pressure Sealed LVDT |
±6,35 mm to ±25,4 mm |
no |
0,2% to 0,25%*1 |
|
|||||||||
![]() |
XS-D Long Stroke-to-Body Length LVDT |
±25,4 mm to ±254 mm |
no |
2,0%*1 |
|
|||||||||
|
|
Inductive LVDTs |
||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Model | Measurement Range |
Spring Load Version |
|
Data Sheet | ||||||||||
| LCIT Linear Position Sensor |
±3 mm to ±75 mm |
no |
0,25% |
|
||||||||||
![]() |
LIPS P100 Cylinder - Linear Position Sensor |
0...20 mm to 0...600 mm |
no |
0,25% to 0,5% |
|
PDF: Position Sensor P100 |
||||||||
![]() |
LIPS P101 Stand Alone Linear Inductive Position Sensor |
0...50 to 0...600 mm |
no |
0,25% to 0,5% |
|
PDF: Position Sensor P101
|
||||||||
![]() |
LIPS P103 Short Stroke Linear Position Senso |
0...10 mm to 0...50 mm |
yes |
0,5% |
|
PDF: Position Sensor P103 |
||||||||
![]() |
LIPS P106 Linear Inductive Position Sensor for Hydraulic Cylinders |
0...20 mm to 0...600 mm |
no |
0,25% to 0,5% |
|
PDF: Position Sensor P106
|
||||||||
![]() |
LIPS P111 Rugged Linear Position Sensor |
0...50 mm to 0...600 mm |
no |
0,25% to 0,5% |
|
PDF: Position Sensor P111
|
||||||||
| LIPS P112 Gauge Head Position Sensor |
0...10 mm to 0...50 mm |
Yes |
0,25% |
|
PDF: Position Sensor P112
|
|||||||||
![]() |
LIPS P113 Slim-Line Linear Position Sensor |
0...10 mm to 0...300 mm |
no |
0,25% |
|
|||||||||
|
|
Intrinsically Safe Inductive Position Sensors |
||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Model | Measurement Range |
Spring Load Version |
|
Data Sheet | ||||||||||
![]() |
LIPS X100 Cylinder - Linear Position Sensor, Intrinsically Safe for Gas |
0...20 mm to 0...600 mm |
no |
0,25% to 0,5% |
|
|||||||||
![]() |
LIPS X101 Stand-Alone Linear Position Sensor, Intrinsically Safe for Gas |
0...50 mm to 0...600 mm |
no |
0,25% to 0,5% |
|
|||||||||
![]() |
LIPS X103 Short Stroke Linear Position Sensor, Intrinsically Safe for Gas |
0...10 mm to 0...50 mm |
yes |
0,5% |
|
|||||||||
![]() |
LIPS X106 Cylinder Sensor with External Electronics, Intrinsically Safe for Gas |
0...20 mm to 0...600 mm |
no |
0,25% to 0,5% |
|
|||||||||
![]() |
LIPS X111 Rugged Stand-Alone Linear Position Sensor, Intrinsically Safe for Gas |
0...50 mm to 0...600 mm |
no |
0,25% to 0,5% |
|
|||||||||
| LIPS X112 Gauge Head Position Sensor, Intrinsically Safe for Gas |
0...10 mm to 0...50 mm |
yes |
0,25% |
|
||||||||||
![]() |
LIPS X113 Slim-lime Linear Postion Sensor, Intrinsically Safe for Gas |
0...10 mm to 0...300 mm |
no |
0,25% |
|
|||||||||
![]() |
BX002 :: BX003 Intrinsically Safe Sensor Barrier for LIPS Sensors |
|
||||||||||||
*from safety barrier BX002 or BX003
| ||||||||||||||
|
|
Displays and Measuring Amplifiers for LVDTs and RVDTs |
||||||
|---|---|---|---|---|---|---|
| Model | Supply Voltage |
Output |
Configuration |
Dimensions W x H x D [mm] |
Data Sheet | |
![]() |
MC-KP-12E/24E-xxx Single channel LVDT/RVDT amplifier |
10 ... 18 VDC 18 ... 30 VDC |
0 ... 10 V ±10 V 4 ... 20 mA |
Plastic enclosure for DIN top hat rail mounting IP20 |
23 x 99 x 115 |
|
| MC-IP-12E/24E-xxx Single channel LVDT/RVDT amplifier in aluminium IP enclosure |
10 ... 18 VDC 18 ... 30 VDC |
0 ... 10 V ±10 V 4 ... 20 mA |
EMC aluminium die-cast enclosure IP65 |
175 x 57 x 80 |
||
![]() |
MC-1K/2K-KA/EK-15B-xxx Single or dual channel LVDT/RVDT amplifier |
±15 VDC regulated |
0 ... 10 V ±10 V ±5 V |
Euroboard / plug-in unit with EMC front panel |
3HE / 7 TE depth euroboard 160 |
|
![]() |
MP2000 Dual channel LVDT readout / controller |
100 to 240 VAC/ 47 ... 63 Hz |
0 ... 10 V ±5 V RS232 |
¼ DIN panel enclosure opt. desktop unit |
99 x 99 x 172,7 |
PDF:
|
![]() |
ATA-2001 LVDT amplifier, analog conditioner with digital calibration |
115 VAC / 50 ... 400 Hz 220 VAC / 50 ... 400 Hz |
0 ... 10 V ±10 V 4 ... 20 mA |
1/8 DIN panel enclosure opt. 19"rack mounting |
96 x 48 x 265,9 |
PDF:
|
![]() |
MCH-P :: MCH-P5 MCH hybrid electronics for inductive transducers |
±15 VDC |
±10 VDC |
Hybrid board |
40,6 x 17,2 (24,2) x 3 |
PDF:
|
|
|
Non-contacting Eddie Current Sensors and Measuring Systems |
|||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Model | Measurement Range |
|
Data Sheet | ||||||||||
![]() |
Sensors | 0,05 mm to 60 mm |
|
||||||||||
| GageProx™ Fixed-gain linear inductive analog proximity sensors developed for metalforming |
0...1,25 mm to 0...3 mm |
1% |
|
||||||||||
![]() |
KD-2306 Non-Contact Position Measuring System |
0...0,5 mm to 0...50 mm |
0,5% to 1% |
|
|||||||||
![]() |
KD-2440 High-precision Proximity Measuring System |
|
|||||||||||
| ThreadChecker™ Non-contact application-specific sensors designed to check thread presence |
Threads M4 to M14 |
|
|||||||||||
INFO: +49 (0)6195 70060 or by e-mail:
info@althen.de
|