? Explanation
  • add to Notepad
  • HTML-Datasheet
  • no Datasheet available
  • Productdetails as PDF

ALS251 Miniature Platform Load Cell

Load Cell ALS251

The ALS251 Miniature Platform Load Cell is a low profile, single point OEM load cell offering high accuracy. Only 0.71" (18 mm) high, the ALS251 is ideal for medical instruments, low profile scales and other low profile, high resolution applications.

A 3000 ohm thin film strain gauge bridge provides extremely low power consumption for battery and current loop applications. Capacities range from 200 g to 10 kg-force full scale (approx. 2 N to 100 N).

Applications

  • Medical Instruments
  • Postal Scales
  • Counting Scales
  • Check Weighing
  • Medical Scales

Features

  • Low Profile
  • Stainless Steel
  • Low Power Consumption
  • Economical
  • Low Hysteresis

Specifications

Parameter

Rated capacity (R.C):

0.2 kg, 0.6 kg, 1 kg, 2 kg, 3 kg, 5 kg, 10 kg (approx. 2 N to 100 N)

Non-linearity:

<0.04 % R.O.

Hysteresis:

<0.02 % R.O.

Creep, 30 min:

<0.05 % R.O.

Non-repeatability:

<0.02 % R.O.

Rated output (R.O.), nominal:

2.0 mV/V

Zero balance:

±0.3 mV/V (optional ±1 % R.O.)

Temperature effect on output:

<0.025 % reading/K (optional <0.002 % reading/K)

Temperature effect on zero balance:

<0.03 % R.O./K (optional <0.004 % R.O./K)

Supply voltage:

5 … 20 VDC or VAC

Bridge configuration:

Full Bridge, 4 wire closed

Bridge resistance:

3000 Ω ±2 %

Insulation resistance (at 50 VDC):

>1000 MΩ

Static overload, safe:

150 % R.C.

Static overload, ultimate:

300 % R.C.

Long term stability:

<0.1 % R.O. / year

Electrical termination:

Stranded PVC wire, 10 x 0.1 mm (approx. 28 AWG) 4 wires,
11.5" (300 mm) long

Material:

Stainless steel,
Model with capacity 0.2 kg: aluminum

Dimensions

Dimensions of load cell ALS251

Dimensions in inches [mm], approx. values. These drawings are for information only and not intended for construction purpose.
Please contact us for detailed drawings.

Electrical Termination

Wiring of load cell ALS251

Wiring:
Red: + supply voltage
Black: - supply voltage
White: + output
Green: - output

Ordering Information

Model

ALS100-xx

xx = Capacity in kg

Safety Note

When using the load cell in tension mode it is essential to provide additional safety precautions like safety chains etc. for catching the load in a breakage, which cannot be excluded completely.