? Explanation
  • add to Notepad
  • HTML-Datasheet
  • no Datasheet available
  • Productdetails as PDF

ATLC Tension Load Cell

Tension Loadcell ATLC

The model ATLC series, designed for tension measurement and weighing applications, are reliable and easy to install.

  • Durable design provides high safety. (ultimate overload rating 500 %)
  • Alloy tool steel construction for high accuracy.
  • Electroless nickel plated for corrosion resistance.

SpecificationsATLC

Rated capacity (RC):

500 kg, 1 t, 2 t, 3 t, 5 t

Non-linearity:

≤0.03 % RO

Hysteresis:

≤0.03 % RO

Creep, 20 min:

≤0.03 %

Repeatability:

≤0.03 % RO

Rated output (RO), rationalised:

1.5 mV/V ±0.25 %

Zero balance:

≤1 % RO

Temperature effect on rated output:

≤0.05 % load/10 K

Temperature effect on zero balance:

≤0.05 % RO/10 K

Compensated temperature range:

-10 … +70 °C

Operating temperature range:

-20 … +80 °C

Supply voltage, recommended:

10 VDC

Supply voltage, max.:

15 VDC

Terminal input resistance:

350 Ω ±3.5 Ω

Terminal output resistance:

350 Ω ±5 Ω

Insulation resistance, min.:

2000 MΩ at 50 VDC

Safe overload:

150 % RC

Ultimate overload:

500 % RC

Environmental protection:

meets IP67

Electr. connection:

Ø7 mm x 6 m (22AWG x 4-core, shielded)

Wiring

Wiring of loadcell  series Axxx

red

+ supply voltage

green

+ output signal

white

- supply voltage

blue

- output signal

bare

screen

Dimensions

Dimensions of loadcell ATLC

Dimensions in ''mm'', all values are approx. values These drawings are for information only and not intended for construction purpose. Please contact us for detailed drawings

Rated capacity A B C D E F G Shackle Weight

500 kg, 1 t
(4.9 kN, 9.8 kN)

255

220

17.5

54

42.9

16

78

G-2130, 5/8"
"Crosby" or equiv.

3.2 kg
(1.8 kg without shackle)

2 t to 5 t
(19.6 kN to 49.0 kN)

342.8

293.6

24.6

72.8

58

22.4

116

G-21310, 7/8" "Crosby"
or equiv.

7.8 kg
4.2 kg without shackle)

Ordering Information

ATLC-xx Rated capacity xx =
 

500 = 500 kg

3T = 3 t

 

1T = 1 t

5T = 5 t

 

2T = 2 t

 

Safety note: It is essential to provide additional safety precautions like safety chains etc. for catching the load in a breakage, which cannot be excluded completely.