AGS4200 General Purpose Pressure Transducer

Pressure Sensor AGS4200

The AGS4200 pressure transmitter is designed for demanding applications where pressure measurement is required and where good quality, fast delivery and low cost are high priority.
The AGS4200 model is the latest addition to a pressue tranducer family, offering outstanding performance due to a unique S.O.S. diaphram construction giving excellent stability over a wide temperature range. Accuracy is +/- 0.25% with an over pressure limit of twice the nominal pressure, together with an output of 4-20 mA and adjustable zero and span for ease of calibration. All models are supplied with 1/4 " BSP thread connection. The titanium pressure ports offer high levels of corrosion resistance.
Applications for the AGS4200 include the continuous monitoring of oil, gas, water and other liquids in the process, industrial, medical and aerospace industries. Also ideal for the measurement and control of pressure in refrigeration, pneumatic, compressor, HVAC and engine monitoring systems.

Models

Model Output signal Supply Voltage Ranges (xxx), gauge pressure

AGS4200L-xxx

4 ... 20 mA 2-wire

13 … 36 VDC

0 … 0.5 bar to 0 … 1 bar

AGS4200-xxx

4 ... 20 mA 2-wire

13 … 36 VDC

0 … 1.6 bar to 0 … 1500 bar

AGS4200L-3L5-xxx

0 ... 5 V 3-wire

13 … 30 VDC

0 … 0.5 bar to 0 … 1 bar

AGS4200-3L5-xxx

0 ... 5 V 3-wire

13 … 30 VDC

0 … 1.6 bar to 0 … 1500 bar

AGS4200L-4L5-xxx

0 ... 5 V 4-wire

13 … 30 VDC

0 … 0.5 bar to 0 … 1 bar

AGS4200-4L5-xxx

0 ... 5 V 4-wire

13 … 30 VDC

0 … 1.6 bar to 0 … 1500 bar

AGS4200L-3L10-xxx

0 ... 10 V 3-wire

13 … 30 VDC

0 … 0.5 bar to 0 … 1 bar

AGS4200-3L10-xxx

0 ... 10 V 3-wire

13 … 30 VDC

0 … 1.6 bar to 0 … 1500 bar

AGS4200L-4L10-xxx

0 ... 10 V 4-wire

13 … 30 VDC

0 … 0.5 bar to 0 … 1 bar

Option HA

enhanced accuracy ±0.1% instead of ±0.25 %

Ordering example: AGS4200-160-G describes a pressure sensor with range 160 bar gauge, output 4 ... 20 mA 2-wire

Specifications

Common Specification for all Models AGS4200:

Pressure ranges:

0 ... 0.5 / 1 / 1.6 / 2.5 / 4 / 6 / 10 / 16 / 25 / 40 / 60 / 100 / 160 / 250 / 400 / 600 / 1000 and 1500 bar

Over pressure:

2 x rated pressure
(for range 1500 bar: 110 % of rated pressure)

Burst pressure:

>300 % of rated pressure for ranges up to 400 bar
>250 % of rated pressure for ranges >400 bar

Pressure reference:

Gauge pressure (G)

Combined non-linearity / hysteresis:

Standard: <±0.25 % FSO
Option HA: <±0.1 % FSO

Repeatability:

<±0.1 % FSO

Long term stability:

<0.2 % for 6 month

Resonant frequency:

Titanium membran >10 kHz

Media temperature range:

-50 °C … +120 °C

Ambient temperature range:

-40 °C … +80 °C

Thermal effect zero:

<±0.03 % FSO/K

Thermal effect sensitivity:

<±0.03 % reading/K

Pressure media:

media compatible with BT9 titanium

Electrical connection:

Connector DIN 43650, optional 1 m cable

Enclosure sealing:

IP65 (when connector is properly installed)

Humidity:

95 % RH

Max. shock:

15 g for 11 ms, in all 3 axes without damage

Max. vibration:

10 g random vibration up to bis 50 Hz without damage

Pressure connection:

G1/4” thread male, others on request