| Model | Measurement Range | Meas. Channels | Resol. | Sample Rate | Interface | Operation | Datasheet | |
![]() |
GL200A Compact datalogger for 10 measurement channels |
20 mV ... 50 V, thermocouples, humidity | 10 | 14 bit | per channel: 10 ms to 1 h (depending on channel number) |
USB | stand-alone, PC based, USB-HD |
|
![]() |
GL220 Compact datalogger for 10 measurement channels |
20 mV ... 50 V, thermocouples, humidity | 10 | 16 bit* | per channel: 10 ms to 1 h (depending on channel number) |
USB | stand-alone, PC based, USB-HD |
|
![]() |
GL820 Datalogger for up to 200 measurement channels |
20 mV ... 50 V, thermocouples, Pt100, JPt100, Pt1000, humidity | 20 to 200 | 16 bit* | per channel: 10 ms to 1 h (depending on channel number) |
Ethernet, USB |
stand-alone, PC based, FTP, HTTP |
|
![]() |
GL900-4 | GL900-8 High-speed datalogger with parallel signal processing |
20 mV ... 500 V, thermocouples, humidity | 8 | 14 bit | per channel: 10 µs to 1 min |
Ethernet, USB |
stand-alone, PC based, FTP, HTTP |
|
![]() |
MT100 Panel mount paperless recorder for rough environment |
20 mV ... 50 V, thermocouples, Pt100, JPt100, Pt1000, humidity | 10 | 14 bit | per channel: 100 ms to 1 h |
Ethernet, USB |
stand-alone, PC based, FTP, HTTP |
|
![]() |
GL1100 Multifunctional measurement data acquisition system |
20 mV ... 500 V, strain gauge, thermocouples | 2 to 16 | 12 bit to 16 bit |
per channel: 25 ns to 10 µs |
Ethernet, USB |
stand-alone, PC based, HTTP |
add to notepad |
![]() |
WR300 | WR310 Multifunctional thermo array recorder with a 210 mm display |
50 mV ... 200 V, strain gauge, frequency, thermocouples | 2 to 16 | 12 bit to 16 bit |
per channel: 1 µs to 10 µs |
Ethernet, USB |
stand-alone, PC based, HTTP |
add to notepad |
| *effective resolution: 1/40000 of measuring full range | ||||||||
| Download: GL Datalogger Software Manuals |
||||||||
| Model | Measurement Range | Measurement Channels | Resol. | Sample Rate | Interface | Operation | Datasheet | |
![]() |
DI-710-UHS Datalogger recording to SD-cards |
±1.25 V ... ±10 V |
16 | 14 bit | Sum: 0.0017 S/s ... 14400 S/s (PC with WinDaq/HS: 4800 S/s) |
Ethernet, USB |
SD card PC based |
|
![]() |
DI-710-ULS Datalogger which records to SD-cards |
±10 mV ... ±10 V |
16 | 14 bit | Sum: 0.0017 S/s ... 14400 S/s (PC with WinDaq/HS: 4800 S/s) |
Ethernet, USB |
SD card PC based |
|
![]() |
DI-715B-ES datalogger for 5B amplifier which records to SD-cards |
±5 V via 5B amplifier | 8 | 14 bit | Sum: 0.0017 S/s ... 14400 S/s (PC with WinDaq/HS: 4800 S/s) |
Ethernet | SD card PC based |
|
![]() |
DI-718B-US / DI-718B-ES Datalogger for 8B amplifier which records to SD-cards |
±5 V via 8B amplifier | 8 | 14 bit | Sum: 0.0017 S/s ... 14400 S/s (PC with WinDaq/HS: 4800 S/s) |
Ethernet USB |
SD card PC based |
|
![]() |
DI-718Bx Datalogger for 8B amplifier which records to SD-cards |
±5 V via 8B amplifier | 16 | 14 bit | Sum: 0.0017 S/s ... 14400 S/s (PC with WinDaq/HS: 4800 S/s) |
Ethernet | SD card PC based |
|
![]() |
M5X Compact high performance datalogger with CAN-bus |
12 ch voltage 0 ... 5 V, 1 ch temperature, 8 ch frequency, 2 ch int. acceleration (XY), 3 ch CAN bus |
16 bit | per channel: 1 kS/s |
Ethernet CAN-Bus |
CF card PC based |
add to notepad | |
![]() |
nanoM5-PRO Compact datalogger with CAN-bus |
3 ch voltage 0 ... 5 V, 2 ch frequency, 1 ch int. temperature, 2 ch int. acceleration, 1 ch differential, 1 ch CAN bus |
16 bit | per channel: 100 S/s |
USB CAN-Bus |
CF card PC based |
add to notepad | |
![]() |
nanoM5-PRO+ Compact datalogger with CAN-bus |
3 ch voltage 0 ... 5 V, 6 ch frequency, 1 ch int. temperature, 1 ch int. acceleration (XY), 1 ch CAN bus |
16 bit | per channel: 100 S/s |
USB CAN-Bus |
CF card PC based |
add to notepad | |
![]() |
nanoM5X Compact datalogger with CAN-bus |
6 ch voltage 0 ... 5 V, 6 ch frequency, 1 ch int. temperature, 1 ch int. acceleration, 1 ch differential, 1 ch CAN bus |
16 bit | per channel: 100 S/s |
Ethernet CAN-Bus |
CF card PC based |
add to notepad | |
| Model | Meas. Range | Meas. Channels | Resol. | Sample Rate | Interface | Operation | Datasheet | |
![]() |
DI-710-UH Measurement data acquisition system |
±1.25 V ... ±10 V |
16 | 14 bit | Sum: 0.014 S/s ... 240 S/s (WinDaq/HS: 14000 S/s) |
Ethernet, USB |
PC based |
|
![]() |
DI-710-UL Measurement data acquisition system |
±10 mV ... ±10 V |
16 | 14 bit | Sum: 0.0034 S/s ... 1108 S/s (WinDaq/HS: 4800 S/s) |
Ethernet, USB |
PC based |
|
![]() |
DI-715B-E Measurement data acquisition system for 5B amplifier |
±5 V via 5B amplifier | 8 + 8 | 14 bit | Sum: 0.0034 S/s ... 1108 S/s (WinDaq/HS: 4800 S/s) |
Ethernet | PC based |
|
![]() |
DI-718B-U / DI-718B-E Measurement data acquisition system for 8B amplifier |
±5 V via 8B amplifier | 8 | 14 bit | Sum: 0.0034 S/s ... 1108 S/s (WinDaq/HS: 4800 S/s) |
Ethernet, USB |
PC based |
|
![]() |
DI-718Bx Measurement data acquisition system for 8B amplifier |
±5 V via 8B amplifier | 16 | 14 bit | Sum: 0.0034 S/s ... 1108 S/s (WinDaq/HS: 4800 S/s) |
Ethernet, USB |
PC based |
|
![]() |
DI-720 Measurement data acquisition system |
±1.25 V ... ±10 V |
32 | 14 bit | Sum: 180 kS/s (E) 200 kS/s (U) 250 kS/s (P) |
Ethernet, USB, Parallel port |
PC based |
|
| DI-730 Measurement data acquisition system |
±10 mV ... ±1000 V and ±1.25 V ... ±10 V |
8 + 16 | 14 bit | all channels: 180 kS/s (E) 200 kS/s (U) 250 kS/s (P) |
Ethernet, USB, Parallel port |
PC based |
|
| Model | Meas. Range | Meas. Channels | Resol. | Sample Rate | Interface | Operation | Datasheet | |
![]() |
DI-194RS | DI-154RS Low priced measurement data acquisition system |
±1.25 V ... ±10 V |
4 | 10 bit or 12 bit | Sum: 0.014 S/s ... 240 S/s |
RS-232 | PC based |
|
![]() |
DI-148U Low priced measurement data acquisition system |
±1.25 V ... ±10 V |
4 | 10 bit | Sum: 0.014 S/s ... 240 S/s (WinDaq/HS: 14000 S/s) |
USB | PC based |
|
![]() |
DI-148U-SP Measurement data acquisition system for potentiometer and analog measuring signals |
±1.25 V ... ±10 V and 2.4 V |
2 + 2 | 10 bit | Sum: 0.014 S/s ... 240 S/s (WinDaq/HS: 14000 S/s) |
USB | PC based | add to notepad |
![]() |
DI-158U Measurement data acquisition system for USB interface |
±1.25 V ... ±10 V |
4 | 12 bit | Sum: 0.014 S/s ... 240 S/s (WinDaq/HS: 14000 S/s) |
USB | PC based |
|
![]() |
DI-158UP Measurement data acquisition system for USB interface |
±125 mV ... ±64 V |
4 | 12 bit | Sum: 0.014 S/s ... 240 S/s (WinDaq/HS: 14000 S/s) |
USB | PC based |
|
![]() |
EL-USB-1 EasyLog datalogger for temperature |
-35 ... + 80 °C | 1 | 0.5 °C | 10 s to 12 hr |
USB | stand-alone |
|
![]() |
EL-USB-2 EasyLog datalogger for temperature and humidity |
-35 ... +80 °C 0 ... 100 % RH |
2 | 0.5 °C 0.5 % RH |
10 s to 12 hr |
USB | stand-alone |
|
![]() |
EL-USB-2+ EasyLog datalogger with higher accuracy for temperature and humidity |
-35 ... +80 °C 0 ... 100 % RH |
2 | 0.5 °C 0.5 % RH |
10 s to 12 hr |
USB | stand-alone |
|
![]() |
EL-USB-2-LCD EasyLog datalogger with display for temperature and humidity |
-35 ... +80 °C 0 ... 100 % RH |
2 | 0.5 °C 0.5 % RH |
10 s to 12 hr |
USB | stand-alone |
|
![]() |
EL-USB-RT EasyLog real-time datalogger for temperature and humidity |
-20 ... +70 °C 0 ... 100 % RH |
2 | 1 s | USB | PC based |
|
|
![]() |
EL-USB-3 EasyLog voltage datalogger |
0 ... 30 V | 1 | 50 mV | 1 s to 12 hr |
USB | stand-alone |
|
![]() |
EL-USB-4 EasyLog current loop datalogger |
4 ... 20 mA | 1 | 0.05 mA | 1 s to 12 hr |
USB | stand-alone |
|
![]() |
EL-USB-CO EasyLog datalogger for carbon monoxide (CO) |
0 ... 1000 ppm | 1 | 0.5 ppm CO | 1 s to 5 min |
USB | stand-alone |
|
![]() |
EL-USB-TC EasyLog datenlogger for thermocouples |
Thermocouples: type J type K type T |
1 | 0.5 °C | 1 s to 12 hr |
USB | stand-alone |
|
| Model | Host Instrument | Measurement Channels | Measurement Range | Housing | Datasheet | |
![]() |
DI-725-7 Analog channel excansion for DI-720, DI-722 and DI-730 |
DI-720 DI-722 DI-730 |
32, cascadable | ±1.25 V ... ±10 V | Desktop |
|
![]() |
DI-725E-7 Analog channel expansion with extended measurement range for DI-720, DI-722, and DI-730 |
DI-720 DI-722 DI-730 |
32, cascadable | ±2.5 V ... ±20 V | Desktop |
|
![]() |
DI-75B-7 5B amplifier expansion unit |
DI-715B DI-720 DI-722 DI-730 |
8 | depending on 5B amplifier | Desktop |
|
![]() |
DI-78B 8B amplifier expansion unit |
DI-720 DI-730 |
16 | depending on 8B amplifier | Desktop | add to notepad |
| Model | Host Instrument | Sample Rate | Language | Operating System | Datasheet | |
![]() |
WinDaq/Lite Free Software for data acquisition and system configuration |
DI-19x DI-14x/DI-15x DI-71x DI-72x/DI-73x |
240 Hz the same for each channel |
English | Windows® 2000 Windows® XP Windows Vista® (32 bit) |
|
![]() |
WinDaq/HS Software for measurement equipment configuration and data recording on PC with the maximum sample rate of the hardware |
DI-14x DI-15x DI-71x |
depending on hardware, the same for each channel | English | Windows® 2000 Windows® XP Windows Vista® (32 bit) |
|
![]() |
WinDaq/Pro Software for measurement equipment configuration and data recording on PC with the maximum sample rate of the hardware |
DI-720 DI-722 DI-730 |
depending on hardware, the same for each channel | English | Windows® 2000 Windows® XP Windows Vista® (32 bit) |
|
![]() |
WinDaq/Pro+ Software for measurement equipment configuration and to record the data on PC with the maximum sample rate of the hardware |
DI-720 DI-722 DI-730 |
depending on hardware, each channel individually | English | Windows® 2000 Windows® XP Windows Vista® (32 bit) |
|
![]() |
WinDaq Waveform Browser Free software for playback and analysis of the recorded data; export to ASCII, CSV and other formats |
Data format: *.WDQ *.WDC |
--- | English | Windows® 2000 Windows® XP Windows Vista® (32 bit) |
|
![]() |
WinDaq/XL Plug-in for real-time transmission of the data to Microsoft® Excel® |
DI-19x DI-14x/DI-15x DI-71x DI-72x/DI-73x |
--- | English | Windows® 2000 Windows® XP Windows Vista® (32 bit) |
|
![]() |
midiLogger Software Free software for configuration, recording and analysis of the data, export to ASCII, Excel® and FlexPro 7 |
GL200 GL800 |
depending on hardware | German | Windows® 2000 Windows® XP Windows Vista® (32 bit) |
add to notepad |
| Model | Features | Datasheet | ||||
![]() ![]() |
InnoBeamer® USB data acquisition device for IEPE vibration sensors, easy to use system for PC-based vibration measurement and analysis |
Overview: VibroMatrix® add to notepad |
||||
| Frequency range | Supply | Interface | Housing | |||
|
InnoBeamer® L2 InnoBeamer® X2 |
0.3 ... 2000 Hz 0.1 ... 40000 Hz |
via USB | USB 2.0, compatible until Windows 7 |
in-line | ||
![]() |
InnoMeter® When vibrations are measured as significant parameters, the InnoMeters are applied. |
The InnoMeters in Standard and in Pro Version are highly universal measuring instruments for vibration parameters. They can be adapted to parameters from numerous vibration standards. Measurands: acceleration, velocity, displacement |
add to notepad |
|||
![]() |
InnoPlotter® When vibration parameters are measured and controlled for a longer time, the InnoPlotters are suitable |
The InnoPlotters in Standard and in Pro Version are universal digital strip chart recorders for vibration parameters. The Pro Version includes two integrators and is consequently able to process not only vibration acceleration, but also vibration velocity and displacement. |
add to notepad |
|||
![]() |
InnoLogger® For the monitoring of vibration parameters and their logging for later analysis |
Rotating parts in drives, gears, pumps, fans and many other technical products cause perturbing vibrations. Impulse-like loads, e.g. from a vibratory pile driver in the construction-field, generate problems as well. |
add to notepad |
|||
![]() |
InnoScope® The InnoScopes allow the signals‘ shape analysis of fast vibration and shock processes in time domain. These processes are acquired and measured with high resolution and can be exported for documentation or postprocessing. |
Another field of application is the determination of natural frequencies. The measurement object is stimulated impulse-like, the InnoScope triggers the event and displays the time course of the signal. A coupled InnoAnalyzer analyzes the triggered time signal and displays it in the frequency domain simultaneously. Natural frequencies can be read off at once. |
add to notepad |
|||
![]() |
InnoAnalyzer® For the frequency analysis of vibrations |
Rotating parts in drives, gears, pumps, fans and many other technical products cause perturbing vibrations. Often numerous parts with different rotation speed cause mechanical vibrations so that a superposition of frequencies is generated. |
add to notepad |
|||
![]() |
InnoAnalyzer® Speed Different rotation speeds cause different vibrations since the measurement objects develop or do not develop resonant behaviour at certain rotation speeds. |
These differences become obviously when measuring run-up or coast-down curves. A rotor changes its rotation speed and excites different frequencies of the system. The InnoAnalyzers Speed measure the vibration level at the rotation speed or a multiple and graphically indicate magnitude and phase at the respective rotation speed. |
add to notepad |
|||
![]() |
InnoBalancer® The InnoBalancers are used for the reduction of vibrations. |
The InnoBalancers allow a purposeful reduction of the vibration by balancing. Both discoidal and longish rotors can be balanced systematically and fast. |
add to notepad |
|||
![]() |
InnoMeter® HVM 5349:2001 Human hand-arm vibration measurement acc. to EN ISO 5349:2001 and EC Directive 2002/44/EC |
If hand held machines or workpieces transmit strong vibrations to the operator, a decreased performance and even diseases in blood vessels, nerves, bones, joints, muscles or the connective tissue might develop. For this reason, divers guidelines stipulate measurements acc. to EN ISO 5349, which determines the impact on the human hand-arm-system. |
add to notepad |
|||
![]() |
InnoMeter® HVM 2631:1997 Human whole-body vibration measurement acc. to EN ISO2631:1997 and EC Directive 2002/44/EC |
If strong vibrations are transmitted to human beings, a decreased performance and even diseases in blood vessels, nerves, bones, joints, muscles or connective tissue might develop. For this reason, divers guidelines stipulate measurements acc. to ISO2631, which assesses the vibration impact on human beings. |
add to notepad |
|||
![]() |
InnoMeter® HVM 6954:2001 Vibration measurement on ships |
On board passenger and merchant vessels vibrations can occur, which may negatively interfere with the work of the crew or which may diminish the comfort of passengers and crew. In order to assess complaints or to prevent them, measurements acc. to DIN ISO 6954:2001 are suitable, since they allow the evaluation of the vibration severity with regard to habitability on board ships. |
add to notepad |
|||
![]() |
InnoMeter® 4150-3 The InnoMeter 4150-3 was developed for the measurement of vibrations on buildings acc. to the German standard DIN 4150-3. |
Vibrations from heavy building activities, traffic, machine operation or also detonations affect existing building stock. The InnoMeter 4150-3 measures these vibrations, valuates acc. to the standard immediately and can inform about the vibrations occured at any time. |
add to notepad |
|||
![]() |
InnoMeter® 3834 The InnoMeter 3834 was developed for the measurement of vibrations on wind energy systems acc. to German standard VDI 3834 |
This instrument allows the measurement and analysis of vibrations on both building constructions (like tower and generator house) and machinery components, like rotor, gear and generator. | add to notepad | |||