| Model | Measurement Range | Output | Accuracy | Size | Datasheet | |
![]() |
8FLP10A Potentiometric position sensor, conductive plastic |
11 mm | 1 kOhm to 20 kOhm |
1 % to 2 % |
Case: 8.2 x 7.3 x 32 mm Shaft diameter 2 mm |
add to notepad |
![]() |
13FLP Potentiometric position sensor, conductive plastic |
12 mm to 100 mm |
500 Ohm to 20 kOhm |
0.3 % to 2 % |
Case: 13 x 11 x 38...127 mm Shaft diameter 3.175 mm |
|
![]() |
30FLP Potentiometric linear displacement sensor, conductive plastic |
100 mm to 1000 mm |
1 kOhm to 500 kOhm |
0.05 % to 0.5 % |
Case: 35 x 32 x 170...1070 mm Shaft diameter approx. 10mm |
|
![]() |
40FLP Potentiometric linear displacement sensor, conductive plastic |
200 mm to 1000 mm |
2 kOhm to 500 kOhm |
0.05 % to 0.5 % |
Case: 47 x 40 x 360...1160 mm |
|
![]() |
CFL Potentiometric displacement sensor |
200 mm to 1000 mm |
2 kOhm to 500 kOhm |
0.05 % to 0.5 % |
Case: 10 x 20 x 250...1050 mm |
|
![]() |
FDPL2S Potentiometric position sensor, conductive plastic |
50 mm to 750 mm |
2 kOhm to 20 kOhm |
0.075 % to 0.1 % |
Case: 31 x 31 x 127...827 mm Shaft diameter 6 mm |
|
![]() |
FDPLS-V | FDPL2S-V | FDPL231-V Potentiometric position sensor, conductive plastic |
50 mm to 950 mm |
0 ... 10 V | Case: 31 x 31 x 190...1090 mm |
|
|
![]() |
FDP60 Draw-wire potentiometer |
100 mm to 1500 mm |
1 kOhm 0 ... 10 V 4 ... 20 mA |
0.1 % to 0.5 % |
60 x 76.5 x 129 mm (Model P) |
add to notepad |
| Model | Measurement Range | Spring-loaded | Accuracy | Output [Supply Voltage] | Datasheet | |
![]() |
DC-EC General purpose LVDT |
±1.25 mm to ±250 mm |
no | 0.25 % | ±10 V [±15 VDC] |
|
![]() |
DC-SE General purpose LVDT |
0 ... 2.5 mm to 0 ... 150 mm |
no | 0.25 % | 0 ... 5 V [8.5 ... 28 VDC] 1 ... 6 V [8.5 ... 28 VDC] |
|
![]() |
E Schaevitz™ Schaevitz™ economical LVDT |
±2.54 mm to ±50.8 mm |
no | 0.5 % or 1.0 % |
18 ... 96 mV/V per mm [3 V rms] |
|
![]() |
GC-485 Schaevitz™ ultra precision digital I/O gage head |
±1.27 mm to ±25.4 mm |
yes | 0.05 % | RS-485 [8.5 ... 30 VDC] |
|
![]() |
GCA | GCD Schaevitz™ precision gage heads, spring-loaded design |
±1.27 mm to ±50.8 mm |
yes | 0.25 % | GCA: 14 ... 168 mV/V per mm [3 V rms] GCD: 0.2 ... 8 V/mm [±15 VDC] |
|
![]() |
GCD-SE Schaevitz™ precision gage heads, spring-loaded design |
0 ... 2.54 mm to 0 ... 50.8 mm |
yes | 0.25 % | 0 ... 5 V [8.5 ... 28 VDC] 1 ... 6 V [8.5 ... 28 VDC] |
|
![]() |
GCT Gage head transmitter |
0 ... 6.35 mm to 0 ... 50.8 mm |
yes | 0.5 % | 4 ... 20 mA [13 ... 28 VDC] |
|
![]() |
HC485 Schaevitz™ RS-485 multi-drop displacement sensor |
±1.27 mm to ±75 mm |
no | 0.25 % | RS-485 [8.5 ... 30 VDC] |
|
![]() |
HCA Schaevitz™ hermetically sealed LVDT |
±1.27 mm to ±254 mm |
no | 0.2 % to 1.0 % |
5 ... 165 mV/V per mm [3 V rms] |
|
![]() |
HCD Schaevitz™ hermetically sealed LVDT |
±1.25 mm to ±250 mm |
no | 0.25 % | ±10 V [±15 VDC] |
|
![]() |
HCT 420-xxx-IS Intrisically safe 2-wire 4...20 mA position transmitter |
0 ... 6.35 mm to 0 ... 254 mm |
no | 0.5 % or 1.0 % |
4 ... 20 mA 2L [13 ... 28 VDC] |
|
![]() |
HR Schaevitz™ general purpose LVDT |
±1.27 mm to ±254 mm |
no | 0.1 % to 1.3 % |
2.8 ... 230 mV/V per mm [3 V rms] |
|
![]() |
LBB High precision gage heads |
±0.02" to ±0.2" (±0.5 mm to ±5 mm) |
yes | 0.2 % | 200 ... 280 mV/V per mm [3,5 V rms] 170 mV/V per mm [5 V rms] |
|
![]() |
M12 Schaevitz™ LVDT |
±10 mm to ±100 mm |
no | 0.25 % | 7.1 ... 42 mV/V per mm [3 V rms] |
|
|
M12SX-30-25-150A-0.1 | M12S-xx-xx-150A-0.1 Special LVDT for steel mill applications |
±20 mm to ±50 mm |
no | 0.1 % | 9 ... 20 mV/V per mm [2.2 V rms] |
|
|
![]() |
MHR Schaevitz™ miniature LVDT |
±0.13 mm to ±50.8 mm |
no | 0.1 % to 0.75 % |
19 ... 342 mV/V per mm [3 V rms] |
|
![]() |
MP Schaevitz™ LVDT |
±12.7 mm to ±254 mm |
no | 0.15 % to 1.3 % |
2.8 ... 25.6 mV/V per mm [3 V rms] |
|
![]() |
PCA 116 Schaevitz™ economy gage heads |
±2.5 mm to ±7.5 mm |
yes | 0.5 % | 48 ... 95 mV/V per mm [3 V rms] |
|
![]() |
PCA-375 Schaevitz™ gage heads |
±2.54 mm to ±25.4 mm |
yes | 0.5 % | 30 ... 110 mV/V per mm [3 V rms] |
|
![]() |
XS-B Schaevitz™ subminiature LVDT |
±2.4 mm ±6.4 mm |
no | 0.2 % to 0.5 % |
56 ... 60 mV/V per mm [1 V rms] |
|
![]() |
XS-C Schaevitz™ high pressure sealed LVDT |
±6.35 mm to ±25.4 mm |
no | 0.2 % to 0.25 % |
32 ... 68 mV/V per mm [3 V rms] |
|
![]() |
XS-D Schaevitz™ long stroke-to-body length LVDT |
±25.4 mm to ±254 mm |
no | 2.0 % | 2 ... 11 mV/V per mm [3 V rms] |
|
| Model | Measurement Range | Spring-loaded | Accuracy | Output [Supply Voltage] | Datasheet | |
| LCIT Schaevitz™ linear position sensor |
±3 mm to ±50 mm |
no | 0.25 % | 0.5 ... 4.5 V [7 ... 36 VDC] |
|
|
![]() |
LIPS P100 Cylinder - linear position sensor |
0 ... 20 mm to 0 ... 600 mm |
no | 0.25 % to 0.5 % |
0.5 ... 4.5 V ratiometric [5 VDC] 0.5 ... 4.5 V [9 ... 28 VDC] ±5 V [±9 ... 28 VDC] 0.5 ... 9.5 V [13 ... 28 VDC] ±10 V [±13.5 ... 28 VDC] 4 ... 20 mA 2L [18 ... 28 VDC] 4 ... 20 mA 3L [13 ... 28 VDC] |
|
![]() |
LIPS P101 Stand alone linear inductive position sensor |
0 ... 50 mm to 0 ... 600 mm |
no | 0.25 % to 0.5 % |
0.5 ... 4.5 V ratiometric [5 VDC] 0.5 ... 4.5 V [9 ... 28 VDC] ±5 V [±9 ... 28 VDC] 0.5 ... 9.5 V [13 ... 28 VDC] ±10 V [±13.5 ... 28 VDC] 4 ... 20 mA 2L [18 ... 28 VDC] 4 ... 20 mA 3L [13 ... 28 VDC] |
|
![]() |
LIPS P103 Short storke linear position sensor |
0 ... 10 mm to 0 ... 50 mm |
yes | 0.25 % | 0.5 ... 4.5 V ratiometric [5 VDC] 0.5 ... 4.5 V [9 ... 28 VDC] ±5 V [±9 ... 28 VDC] 0.5 ... 9.5 V [13 ... 28 VDC] ±10 V [±13.5 ... 28 VDC] 4 ... 20 mA 2L [18 ... 28 VDC] 4 ... 20 mA 3L [13 ... 28 VDC] |
|
![]() |
LIPS P106 Linear inductive position sensor for hydraulic cylinders |
0 ... 20 mm to 0 ... 600 mm |
no | 0.25 % to 0.5 % |
0.5 ... 4.5 V ratiometric [5 VDC] 0.5 ... 4.5 V [9 ... 28 VDC] ±5 V [±9 ... 28 VDC] 0.5 ... 9.5 V [13 ... 28 VDC] ±10 V [±13.5 ... 28 VDC] 4 ... 20 mA 2L [18 ... 28 VDC] 4 ... 20 mA 3L [13 ... 28 VDC] |
|
![]() |
LIPS P111 Rugged linear position sensor |
0 ... 50 mm to 0 ... 600 mm |
no | 0.25 % to 0.5 % |
0.5 ... 4.5 V ratiometric [5 VDC] 0.5 ... 4.5 V [9 ... 28 VDC] ±5 V [±9 ... 28 VDC] 0.5 ... 9.5 V [13 ... 28 VDC] ±10 V [±13.5 ... 28 VDC] 4 ... 20 mA 2L [18 ... 28 VDC] 4 ... 20 mA 3L [13 ... 28 VDC] |
|
![]() |
LIPS P112 Gauge head position sensor |
0 ... 10 mm to 0 ... 50 mm |
yes | 0.25 % | 0.5 ... 4.5 V ratiometric [5 VDC] |
|
![]() |
LIPS P117 Slim-line linear position sensor |
0 ... 10 mm to 0 ... 300 mm |
no | 0.25 % | 0.5 ... 4.5 V ratiometric [5 VDC] 0.5 ... 4.5 V [9 ... 28 VDC] 0.5 ... 9.5 V [13 ... 28 VDC] |
|
| Model | Measurement Range | Spring-loaded | Accuracy | Output [Supply Voltage] | Datasheet | |
![]() |
LIPS X100 Cylinder - linear position sensor, intrinsically safe for hazardous gas/vapour atmospheres |
0 ... 20 mm to 0 ... 600 mm |
no | 0.25 % to 0.5 % |
0.5 ... 9.5 V [20 ... 35 VDC]* 4 ... 20 mA [20 ... 35 VDC]* |
|
![]() |
LIPS X101 Stand-alone linear position sensor, intrinsically safe for hazardous gas/vapour atmospheres |
0 ... 50 mm to 0 ... 600 mm |
no | 0.25 % to 0.5 % |
0.5 ... 9.5 V [20 ... 35 VDC]* 4 ... 20 mA [20 ... 35 VDC]* |
|
![]() |
LIPS X103 Short stroke linear position sensor, intrinsically safe for hazardous gas/vapour atmospheres |
0 ... 10 mm to 0 ... 50 mm |
yes | 0.25 % | 0.5 ... 9.5 V [20 ... 35 VDC]* 4 ... 20 mA [20 ... 35 VDC]* |
|
![]() |
LIPS X106 Cylinder sensor with external electronics, intrinsically safe for hazardous gas/vapour atmospheres |
0 ... 20 mm to 0 ... 600 mm |
no | 0.25 % to 0.5 % |
0.5 ... 9.5 V [20 ... 35 VDC]* 4 ... 20 mA [20 ... 35 VDC]* |
|
![]() |
LIPS X111 Ruged stand-alone linear position sensor, intrinsically safe for hazardous gas/vapour atmospheres |
0 ... 50 mm to 0 ... 600 mm |
no | 0.25 % to 0.5 % |
0.5 ... 9.5 V [20 ... 35 VDC]* 4 ... 20 mA [20 ... 35 VDC]* |
|
![]() |
LIPS X112 Gauge head position sensor, intrinsically safe for hazardous gas/vapour atmospheres |
0 ... 10 mm to 0 ... 50 mm |
yes | 0.25 % | 0.5 ... 9.5 V [20 ... 35 VDC]* 4 ... 20 mA [20 ... 35 VDC]* |
|
![]() |
LIPS X117 Slim-line linear position sensor, intrinsically safe for hazardous gas/vapour atmospheres |
0 ... 10 mm to 0 ... 300 mm |
no | 0.25 % | 0.5 ... 9.5 V [20 ... 35 VDC]* 4 ... 20 mA [20 ... 35 VDC]* |
|
![]() |
BX002 | BX003 Safety barrier |
0.5 ... 9.5 V [20 ... 35 VDC] 4 ... 20 mA [20 ... 35 VDC] |
|
|||
| *via safety barrier BX002 or BX003 | ||||||
| Model | Supply Voltage | Output | Configuration | Size WxHxD [mm] |
Datasheet | |
![]() |
MC-KP-12E/24E-xxx Single channel LVDT/RVDT amplifier |
10 ... 18 VDC 18 ... 30 VDC |
0 ... 10 V ±10 V 4 ... 20 mA |
Plastic enclosure for DIN top hat rail mounting IP20 |
23 x 99 x 115 |
|
![]() |
MC-IP-12E/24E-xxx Single channel LVDT/RVDT amplifier in aluminium IP enclosure |
10 ... 18 VDC 18 ... 30 VDC |
0 ... 10 V ±10 V 4 ... 20 mA |
EMC aluminium die-cast enclosure IP65 |
175 x 57 x 80 |
add to notepad |
![]() |
MC-1K/2K-KA/EK-15B-xxx Single or dual channel LVDT/RVDT amplifier |
±15 VDC regulated | 0 ... 10 V ±10 V ±5 V |
Euroboard / plug-in unit with EMC front panel | 3HE / 7 TE depth euroboard 160 |
add to notepad |
![]() |
BG-NT-115/230 Rack or desktop unit for LVDT amplifier type MC-1K/K-KA/EK-15B-xxx, EMC Version |
115VAC 50/60Hz 230VAC 50/60Hz internal: ±15VDC regulated |
depending on amplifier, output via SUB-D socket | 19" rack or desktop unit |
450 x 134 x 340 (84TE version) |
add to notepad |
![]() |
MP2000 Dual channel LVDT readout / controller |
100 to 240 VAC / 47 ... 63 Hz |
0 ... 10 V ±5 V RS232 |
¼ DIN panel enclosure or desktop unit | 99 x 99 x 172.7 |
|
![]() |
ATA-2001 LVDT Amplifier, analog conditioner with digital calibration |
115 VAC / 50...400 Hz 220 VAC / 50...400 Hz |
0 ... 10 V ±10 V 4 ... 20 mA |
1/8 DIN panel enclosure opt. 19" rack mounting |
96 x 48 x 265.9 |
|
![]() |
MCH-P | MCH-P5 MCH hybrid electronics for inductive transducers |
±15 VDC | ±10 VDC | Hybrid board | 40.6 x 17.2 (24.2) x 3 |
add to notepad |
| Model | Measurement Range | Accuracy | Output [Supply Voltage] | Datasheet | |
![]() |
Eddie current sensors for non-contact position sensing |
0.5 mm to 60 mm |
depending on measuring system | depending on measuring system |
|
![]() |
DIT-5200 Differential impedance transducer |
±0.25 mm to ±1.91 mm |
0.1 % to 1 % |
±10 V [±15 VDC] |
|
![]() |
KD-2306 Single channel multi-purpose non-contact displacement sensing system |
0 ... 0.5 mm to 0 ... 60 mm |
sensor dependent | 0 ... 10 V [15 ... 30 VDC] or 0 ... 5 V, ±5 V, 4 ... 20 mA |
|
![]() |
KD-2446 High-precision proximity measuring system |
0 ... 0.5 mm to 0 ... 15 mm |
see datasheet | 0 ... 10 V [12 VDC] 0 ... 22 V [24 VDC] |
|
|
KD-5100 Differential measuring system |
±0.889 mm and ±1.905 mm |
0.1 % to 0.5 % |
±10 V [±15 VDC] |
|
|
|
KDM-8200 Scalable high precision measuring system |
0 ... 0.5 mm to 0 ... 4 mm |
0.5 % | ±5 V [±15 VDC] |
|
|
|
ThreadChecker™ Non-contact application-specific sensor designed to check thread presence |
Threads M4 to M14 | NPN switching output and 0 ... 10 V [15 ... 30 VDC] |
|