and latest info

table contents

your product notes / Contact

(0)
Close
Close
Tutorials zur Messdatenerfassung
Tutorials und Videos

zu Messdatenerfassung, Datenlogger und taktile Messsysteme

mehr
Datenlogger GL900 mit Display
GL-900

Kompakter Datenlogger mit 4- oder 8 Messkanälen und Abtastrate bis 20 µs je Messkanal

mehr
Close

Potentiometric Position Sensors

top
Model Measurement Range Output Accuracy Size Datasheet
8FLP10A
Potentiometric position sensor, conductive plastic
11 mm 1 kOhm to
20 kOhm
1 %
to
2 %
Case:
8.2 x 7.3 x 32 mm
Shaft diameter 2 mm
Potentiometer 8FLP10A
Technical Information
add to notepad
13FLP
Potentiometric position sensor, conductive plastic
12 mm to
100 mm
500 Ohm to
20 kOhm
0.3 %
to
2 %
Case:
13 x 11 x 38...127 mm
Shaft diameter 3.175 mm
Potentiometer 13FLP
Technical Information add to notepad
30FLP
Potentiometric linear displacement sensor, conductive plastic
100 mm to
1000 mm
1 kOhm to
500 kOhm
0.05 %
to
0.5 %
Case:
35 x 32 x 170...1070 mm
Shaft diameter approx. 10mm
Potentiometer 30FLP
Technical Information add to notepad
40FLP
Potentiometric linear displacement sensor, conductive plastic
200 mm to
1000 mm
2 kOhm to
500 kOhm
0.05 %
to
0.5 %
Case:
47 x 40 x 360...1160 mm
Potentiometer 40FLP
Technical Information add to notepad
CFL
Potentiometric displacement sensor
200 mm to
1000 mm
2 kOhm to
500 kOhm
0.05 %
to
0.5 %
Case:
10 x 20 x 250...1050 mm
Potentiometer CFL
Technical Information add to notepad
FDPL2S
Potentiometric position sensor, conductive plastic
50 mm to
750 mm
2 kOhm to
20 kOhm
0.075 %
to
0.1 %
Case:
31 x 31 x 127...827 mm
Shaft diameter 6 mm
Potentiometer FDPL2S
Technical Information add to notepad
FDPLS-V |
FDPL2S-V |
FDPL231-V

Potentiometric position sensor, conductive plastic
50 mm to
950 mm
0 ... 10 V Case:
31 x 31 x 190...1090 mm
Potentiometer FDPLS-V
Technical Information add to nodepad
FDP60
Draw-wire potentiometer
100 mm to
1500 mm
1 kOhm
0 ... 10 V
4 ... 20 mA
0.1 %
to
0.5 %
60 x 76.5 x 129 mm
(Model P)
Potentiometer FDP60
add to notepad

LVDT Transducers

top
Model Measurement Range Spring-loaded Accuracy Output [Supply Voltage] Datasheet
DC-EC
General purpose LVDT
±1.25 mm to
±250 mm
no 0.25 % ±10 V [±15 VDC] LVDT DC-EC add to notepad
DC-SE
General purpose LVDT
0 ... 2.5 mm to
0 ... 150 mm
no 0.25 % 0 ... 5 V [8.5 ... 28 VDC]
1 ... 6 V [8.5 ... 28 VDC]
LVDT DC-SE add to notepad
E
Schaevitz™
Schaevitz™ economical LVDT
±2.54 mm to
±50.8 mm
no 0.5 %
or
1.0 %
18 ... 96 mV/V per mm
[3 V rms]
LVDT E add to notepad
GC-485
Schaevitz™ ultra precision digital I/O gage head
±1.27 mm to
±25.4 mm
yes 0.05 % RS-485 [8.5 ... 30 VDC] LVDT GC-485 add to notepad
GCA | GCD
Schaevitz™ precision gage heads, spring-loaded design
±1.27 mm to
±50.8 mm
yes 0.25 % GCA:
14 ... 168 mV/V per mm [3 V rms]
GCD:
0.2 ... 8 V/mm [±15 VDC]
LVDT GCA | GCD add to notepad
GCD-SE
Schaevitz™ precision gage heads, spring-loaded design
0 ... 2.54 mm to
0 ... 50.8 mm
yes 0.25 % 0 ... 5 V [8.5 ... 28 VDC]
1 ... 6 V [8.5 ... 28 VDC]
LVDT GCD-SE add to notepad
GCT
Gage head transmitter
0 ... 6.35 mm to
0 ... 50.8 mm
yes 0.5 % 4 ... 20 mA [13 ... 28 VDC] LVDT GCT add to notepad
HC485
Schaevitz™ RS-485 multi-drop displacement sensor
±1.27 mm to
±75 mm
no 0.25 % RS-485 [8.5 ... 30 VDC] LVDT HC485 add to notepad
HCA
Schaevitz™ hermetically sealed LVDT
±1.27 mm to
±254 mm
no 0.2 %
to
1.0 %
5 ... 165 mV/V per mm
[3 V rms]
LVDT HCA add to notepad
HCD
Schaevitz™ hermetically sealed LVDT
±1.25 mm to
±250 mm
no 0.25 % ±10 V [±15 VDC] LVDT HCD add to notepad
HCT 420-xxx-IS
Intrisically safe 2-wire 4...20 mA position transmitter
0 ... 6.35 mm to
0 ... 254 mm
no 0.5 %
or
1.0 %
4 ... 20 mA 2L [13 ... 28 VDC] LVDT HCT-IS add to notepad
HR
Schaevitz™ general purpose LVDT
±1.27 mm
to
±254 mm
no 0.1 %
to
1.3 %
2.8 ... 230 mV/V per mm
[3 V rms]
LVDT HR add to notepad
LBB
High precision gage heads
±0.02" to ±0.2"
(±0.5 mm to ±5 mm)
yes 0.2 % 200 ... 280 mV/V per mm
[3,5 V rms]
170 mV/V per mm
[5 V rms]
LVDT LBB add to notepad
M12
Schaevitz™ LVDT
±10 mm to
±100 mm
no 0.25 % 7.1 ... 42 mV/V per mm
[3 V rms]
LVDT M12 add to notepad
M12SX-30-25-150A-0.1 | M12S-xx-xx-150A-0.1
Special LVDT for steel mill applications
±20 mm to
±50 mm
no 0.1 % 9 ... 20 mV/V per mm
[2.2 V rms]
LVDT M12S add to notepad
MHR
Schaevitz™ miniature LVDT
±0.13 mm to
±50.8 mm
no 0.1 %
to
0.75 %
19 ... 342 mV/V per mm
[3 V rms]
LVDT MHR add to notepad
MP
Schaevitz™ LVDT
±12.7 mm to
±254 mm
no 0.15 %
to
1.3 %
2.8 ... 25.6 mV/V per mm
[3 V rms]
LVDT MP add to notepad
PCA 116
Schaevitz™ economy gage heads
±2.5 mm to
±7.5 mm
yes 0.5 % 48 ... 95 mV/V per mm
[3 V rms]
LVDT PCA 116 add to notepad
PCA-375
Schaevitz™ gage heads
±2.54 mm to
±25.4 mm
yes 0.5 % 30 ... 110 mV/V per mm
[3 V rms]
LVDT PCA 375 add to notepad
XS-B
Schaevitz™ subminiature LVDT
±2.4 mm
±6.4 mm
no 0.2 %
to
0.5 %
56 ... 60 mV/V per mm
[1 V rms]
LVDT XS-B add to notepad
XS-C
Schaevitz™ high pressure sealed LVDT
±6.35 mm to
±25.4 mm
no 0.2 %
to
0.25 %
32 ... 68 mV/V per mm
[3 V rms]
LVDT XS-C add to notepad
XS-D
Schaevitz™ long stroke-to-body length LVDT
±25.4 mm to
±254 mm
no 2.0 % 2 ... 11 mV/V per mm
[3 V rms]
LVDT XS-D add to notepad

Inductive Position Sensors

top
Model Measurement Range Spring-loaded Accuracy Output [Supply Voltage] Datasheet
LCIT
Schaevitz™ linear position sensor
±3 mm to
±50 mm
no 0.25 % 0.5 ... 4.5 V [7 ... 36 VDC] Position Sensor LCIT add to notepad
LIPS P100
Cylinder - linear position sensor
0 ... 20 mm to
0 ... 600 mm
no 0.25 %
to
0.5 %
0.5 ... 4.5 V ratiometric [5 VDC]
0.5 ... 4.5 V [9 ... 28 VDC]
±5 V [±9 ... 28 VDC]
0.5 ... 9.5 V [13 ... 28 VDC]
±10 V [±13.5 ... 28 VDC]
4 ... 20 mA 2L [18 ... 28 VDC]
4 ... 20 mA 3L [13 ... 28 VDC]
Position Sensor P100 add to notepad
LIPS P101
Stand alone linear inductive position sensor
0 ... 50 mm to
0 ... 600 mm
no 0.25 %
to
0.5 %
0.5 ... 4.5 V ratiometric [5 VDC]
0.5 ... 4.5 V [9 ... 28 VDC]
±5 V [±9 ... 28 VDC]
0.5 ... 9.5 V [13 ... 28 VDC]
±10 V [±13.5 ... 28 VDC]
4 ... 20 mA 2L [18 ... 28 VDC]
4 ... 20 mA 3L [13 ... 28 VDC]
Position Sensor P101 add to notepad
LIPS P103
Short storke linear position sensor
0 ... 10 mm to
0 ... 50 mm
yes 0.25 % 0.5 ... 4.5 V ratiometric [5 VDC]
0.5 ... 4.5 V [9 ... 28 VDC]
±5 V [±9 ... 28 VDC]
0.5 ... 9.5 V [13 ... 28 VDC]
±10 V [±13.5 ... 28 VDC]
4 ... 20 mA 2L [18 ... 28 VDC]
4 ... 20 mA 3L [13 ... 28 VDC]
Position Sensor P103 add to notepad
LIPS P106
Linear inductive position sensor for hydraulic cylinders
0 ... 20 mm to
0 ... 600 mm
no 0.25 %
to
0.5 %
0.5 ... 4.5 V ratiometric [5 VDC]
0.5 ... 4.5 V [9 ... 28 VDC]
±5 V [±9 ... 28 VDC]
0.5 ... 9.5 V [13 ... 28 VDC]
±10 V [±13.5 ... 28 VDC]
4 ... 20 mA 2L [18 ... 28 VDC]
4 ... 20 mA 3L [13 ... 28 VDC]
Position Sensor P106 add to notepad
LIPS P111
Rugged linear position sensor
0 ... 50 mm to
0 ... 600 mm
no 0.25 %
to
0.5 %
0.5 ... 4.5 V ratiometric [5 VDC]
0.5 ... 4.5 V [9 ... 28 VDC]
±5 V [±9 ... 28 VDC]
0.5 ... 9.5 V [13 ... 28 VDC]
±10 V [±13.5 ... 28 VDC]
4 ... 20 mA 2L [18 ... 28 VDC]
4 ... 20 mA 3L [13 ... 28 VDC]
Position Sensor P111 add to notepad
LIPS P112
Gauge head position sensor
0 ... 10 mm to
0 ... 50 mm
yes 0.25 % 0.5 ... 4.5 V ratiometric [5 VDC] Position Sensor P112 add to notepad
LIPS P117
Slim-line linear position sensor
0 ... 10 mm to
0 ... 300 mm
no 0.25 % 0.5 ... 4.5 V ratiometric [5 VDC]
0.5 ... 4.5 V [9 ... 28 VDC]
0.5 ... 9.5 V [13 ... 28 VDC]
Position Sensor P117 add to notepad

Intrinsically-Safe Inductive Position Sensors

top
Model Measurement Range Spring-loaded Accuracy Output [Supply Voltage] Datasheet
LIPS X100
Cylinder - linear position sensor,
intrinsically safe for hazardous gas/vapour atmospheres
0 ... 20 mm to
0 ... 600 mm
no 0.25 %
to
0.5 %
0.5 ... 9.5 V [20 ... 35 VDC]*
4 ... 20 mA [20 ... 35 VDC]*
Position Transducer X100 add to notepad
LIPS X101
Stand-alone linear position sensor,
intrinsically safe for hazardous gas/vapour atmospheres
0 ... 50 mm to
0 ... 600 mm
no 0.25 %
to
0.5 %
0.5 ... 9.5 V [20 ... 35 VDC]*
4 ... 20 mA [20 ... 35 VDC]*
Position Transducer X101 add to notepad
LIPS X103
Short stroke linear position sensor,
intrinsically safe for hazardous gas/vapour atmospheres
0 ... 10 mm to
0 ... 50 mm
yes 0.25 % 0.5 ... 9.5 V [20 ... 35 VDC]*
4 ... 20 mA [20 ... 35 VDC]*
Position Transducer X103 add to notepad
LIPS X106
Cylinder sensor with external electronics,
intrinsically safe for hazardous gas/vapour atmospheres
0 ... 20 mm to
0 ... 600 mm
no 0.25 %
to
0.5 %
0.5 ... 9.5 V [20 ... 35 VDC]*
4 ... 20 mA [20 ... 35 VDC]*
Position Transducer X106 add to notepad
LIPS X111
Ruged stand-alone linear position sensor,
intrinsically safe for hazardous gas/vapour atmospheres
0 ... 50 mm to
0 ... 600 mm
no 0.25 %
to
0.5 %
0.5 ... 9.5 V [20 ... 35 VDC]*
4 ... 20 mA [20 ... 35 VDC]*
Position Transducer X111 add to notepad
LIPS X112
Gauge head position sensor,
intrinsically safe for hazardous gas/vapour atmospheres
0 ... 10 mm to
0 ... 50 mm
yes 0.25 % 0.5 ... 9.5 V [20 ... 35 VDC]*
4 ... 20 mA [20 ... 35 VDC]*
Position Transducer X112 add to notepad
LIPS X117
Slim-line linear position sensor,
intrinsically safe for hazardous gas/vapour atmospheres
0 ... 10 mm to
0 ... 300 mm
no 0.25 % 0.5 ... 9.5 V [20 ... 35 VDC]*
4 ... 20 mA [20 ... 35 VDC]*
Position Transducer X117 add to notepad
BX002 | BX003
Safety barrier
0.5 ... 9.5 V [20 ... 35 VDC]
4 ... 20 mA [20 ... 35 VDC]
Safety Barrier BX002/3 add to notepad
*via safety barrier BX002 or BX003

Displays and Measuring Amplifiers for LVDTs and RVDTs

top
Model Supply Voltage Output Configuration Size
WxHxD [mm]
Datasheet
MC-KP-12E/24E-xxx
Single channel LVDT/RVDT amplifier
10 ... 18 VDC
18 ... 30 VDC
0 ... 10 V
±10 V
4 ... 20 mA
Plastic enclosure for DIN top hat rail mounting
IP20
23 x 99 x 115 Amplifier MC-KP add to notepad
MC-IP-12E/24E-xxx
Single channel LVDT/RVDT amplifier in aluminium IP enclosure
10 ... 18 VDC
18 ... 30 VDC
0 ... 10 V
±10 V
4 ... 20 mA
EMC aluminium die-cast enclosure
IP65
175 x 57 x 80 Amplifier MC-IP
add to notepad
MC-1K/2K-KA/EK-15B-xxx
Single or dual channel LVDT/RVDT amplifier
±15 VDC regulated 0 ... 10 V
±10 V
±5 V
Euroboard / plug-in unit with EMC front panel 3HE / 7 TE
depth euroboard 160
add to notepad
BG-NT-115/230
Rack or desktop unit for LVDT amplifier type MC-1K/K-KA/EK-15B-xxx, EMC Version
115VAC 50/60Hz
230VAC 50/60Hz
internal:
±15VDC regulated
depending on amplifier, output via SUB-D socket 19" rack
or
desktop unit
450 x 134 x 340
(84TE version)
add to notepad
MP2000
Dual channel LVDT readout / controller
100 to 240 VAC /
47 ... 63 Hz
0 ... 10 V
±5 V
RS232
¼ DIN panel enclosure or desktop unit 99 x 99 x 172.7 Amplifier MP2000 add to notepad
ATA-2001
LVDT Amplifier, analog conditioner with digital calibration
115 VAC / 50...400 Hz
220 VAC / 50...400 Hz
0 ... 10 V
±10 V
4 ... 20 mA
1/8 DIN panel enclosure
opt. 19" rack mounting
96 x 48 x 265.9 Amplifier ATA-2001 add to notepad
MCH-P | MCH-P5
MCH hybrid electronics for inductive transducers
±15 VDC ±10 VDC Hybrid board 40.6 x 17.2 (24.2)
x 3
add to notepad

Non-contacting Eddie Current Sensors and Measuring Systems

top
Model Measurement Range Accuracy Output [Supply Voltage] Datasheet
Eddie current sensors
for non-contact position sensing
0.5 mm to
60 mm
depending on measuring system depending on measuring system Eddie Current Sensors Overview add to notepad
DIT-5200
Differential impedance transducer
±0.25 mm to
±1.91 mm
0.1 %
to
1 %
±10 V [±15 VDC] Eddie Current Sensor DIT-5200 add to notepad
KD-2306
Single channel multi-purpose non-contact displacement sensing system
0 ... 0.5 mm to
0 ... 60 mm
sensor dependent 0 ... 10 V [15 ... 30 VDC]
or
0 ... 5 V, ±5 V, 4 ... 20 mA
Eddie Current Sensor KD-2306 add to notepad
KD-2446 - non-contact position measurement KD-2446
High-precision proximity measuring system
0 ... 0.5 mm to
0 ... 15 mm
see datasheet 0 ... 10 V [12 VDC]
0 ... 22 V [24 VDC]
Eddie Current Sensor KD-2446 add to notepad
KD-5100
Differential measuring system
±0.889 mm and
±1.905 mm
0.1 %
to
0.5 %
±10 V [±15 VDC] Eddie Current Sensor KD-5100 add to notepad
KDM-8200
Scalable high precision measuring system
0 ... 0.5 mm to
0 ... 4 mm
0.5 % ±5 V [±15 VDC] Eddie Current Sensor KDM-8200 add to notepad
ThreadChecker™
Non-contact application-specific sensor designed to check thread presence
Threads M4 to M14 NPN switching output
and
0 ... 10 V [15 ... 30 VDC]