| Model | Measurement Range | Tension/ Compression | Accuracy | Output [Supply Voltage] | Datasheet | |
![]() |
ABCCU Canister type compression load cell |
0 ... 10 t to 0 ... 50 t |
Compression | 0.02 % | rational. 1.5 mV/V ±0.1 % [10 VDC, max. 15 VDC] |
|
![]() |
ABCH Compression load cell |
0 ... 1 t to 0 ... 50 t |
Compression | 0.05 % | rational. 1.0 mV/V ±1.0 % [10 VDC, max. 15 VDC] |
|
![]() |
ACCDH | ACCDHS Canister type compression load cell |
0 ... 10 t to 0 ... 200 t |
Compression | 0.01 % (up to 100 t) |
rational. 1.5 mV/V ±0.5 % [10 VDC, max. 15 VDC] |
|
|
ACCDM Canister type compression load cell |
0 ... 10 t to 0 ... 200 t |
Compression | 0.1 % | rational. 1.5 mV/V ±0.5 % [10 VDC, max. 15 VDC] |
|
|
![]() |
ACR Compression load cell |
0 ... 200 kg to 0 ... 20 t |
Compression | 0.02 % 0.05 % 0.1 % |
rational. 3.0 mV/V ±0.1 % rational. 3.0 mV/V ±0.1 % rational. 3.0 mV/V ±0.2 % [10 VDC, max. 15 VDC] |
|
![]() |
ATR Canister type tension load cell |
0 ... 100 kg to 0 ... 20 t |
Tension | 0.02 % 0.05 % 0.1 % |
rational. 3.0 mV/V ±0.1 % rational. 3.0 mV/V ±0.1 % rational. 3.0 mV/V ±0.2 % [10 VDC, max. 15 VDC] |
|
![]() |
ALF204 Universal load cell |
0 ... 10 kN to 0 ... 500 kN |
Tension/ Compression | 0.2 % or 0.5 % |
1.2 mV/V or rational. 1.0 mV/V ±0.5 % [10 VDC, max. 20 VDC] 4 ... 20 mA 2L [20 ... 36 VDC] 4 ... 20 mA 3L [11.5 ... 12.5 VDC] 4 ... 20 mA 3L [15 ... 30 VDC] ±10 V [14 ... 27 VDC] |
|
![]() |
ALF214 Load stud |
0 ... 15 kN 0 ... 30 kN 0 ... 60 kN |
Tension/ Compression | 0.1 % | 1.2 mV/V [10 VDC] rational. 1.0 mV/V ±0.5 % [10 VDC] |
|
![]() |
ALF241 Axial compensated load cell |
0 ... 30 N to 0 ... 300 N |
Tension/ Compression | 0.05 % | 2.2 mV/V [10 VDC] rational. 2.0 mV/V ±0.1 % [10 VDC] |
|
![]() |
ALF245 Axial compensated load cell |
0 ... 100 N to 0 ... 800 N |
Tension/ Compression | 0.1 % | 2.2 mV/V [10 VDC] rational. 2.0 mV/V ±0.1 % [10 VDC] |
|
![]() |
ALF256 Axial compensated load cell |
0 ... 0.2 kN to 0 ... 60 kN |
Tension/ Compression | 0.05 % |
rational. 2.0 mV/V ±0.1 % [10 VDC, max. 20 VDC] 4 ... 20 mA 2L [20 ... 36 VDC] 4 ... 20 mA 3L [11.5 ... 12.5 VDC] 4 ... 20 mA 3L [15 ... 30 VDC] ±10 V [14 ... 27 VDC] |
|
![]() |
ALF257 Axial compensated load cell |
0 ... 80 kN to 0 ... 240 kN |
Tension/ Compression | 0.1 % |
rational. 2.0 mV/V ±0.1 % [10 VDC, max. 20 VDC] 4 ... 20 mA 2L [20 ... 36 VDC] 4 ... 20 mA 3L [11.5 ... 12.5 VDC] 4 ... 20 mA 3L [15 ... 30 VDC] ±10 V [14 ... 27 VDC] |
|
![]() |
ALF317 High performance fatigue rated cylindrical load cell |
0 ... 5 kN to 0 ... 1000 kN |
Tension/ Compression | 0.05 % |
1.2 mV/V rational. 1.0 mV/V ±0.1 % [10 VDC, max. 20 VDC] 4 ... 20 mA 2L [20 ... 36 VDC] 4 ... 20 mA 3L [11.5 ... 12.5 VDC] 4 ... 20 mA 3L [15 ... 30 VDC] ±10 V [14 ... 27 VDC] |
|
![]() |
ALF327 Canister load cell |
0 ... 10 kN to 0 ... 2000 kN |
Compression | 0.05 % or 0.1 % |
1.2 mV/V rational. 1.0 mV/V ±0.5 % [10 VDC, max. 20 VDC] |
|
![]() |
CPA Compression load cell |
0 ... 2 t to 0 ... 1000 t |
Compression | 0.25 % | 1.5 mV/V [10 VDC, max. 15 VDC] with integral electronics available |
add to notepad |
![]() |
ELHS Load cell |
0 ... 1 kN to 0 ... 50 kN |
Tension/ Compression | 0.5 % | 13.3 mV/V [15 VDC] |
|
![]() |
TCA Load cell |
0 ... 1 t to 0 ... 100 t |
Tension/ Compression | 0.2 % | 1.5 mV/V [10 VDC, max. 15 VDC] | add to notepad |
| Model | Measurement Range | Tension/ Compression | Accuracy | Output [Supply Voltage] | Datasheet | |
![]() |
11E Miniature tension and compression sensor |
0 ... 1.5 N to 0 ... 5 kN |
Tension/ Compression | 0.5 % | 2 to 10 mV/V [5 VDC], depending on range |
add to notepad |
![]() |
13E Miniature compression sensor |
0 ... 0.5 N to 0 ... 5 kN |
Compression | 0.5 % | 2 to 15 mV/V [5 VDC], depending on range |
|
![]() |
31E Miniature tension and compression force sensor |
0 ... 0.5 N to 0 ... 50 kN |
Tension/ Compression | 0.15 % or 0.2 % |
1.5 to 20 mV/V [5 or 10 VDC], depending on range |
|
![]() |
53E Compact high precision load cell |
0 ... 20 N to 0 ... 200 kN |
Compression | 0.5 % | 2 mV/V [5 or 10 VDC], depending on range |
|
![]() |
ACBES Compression low profile load cell |
0 ... 50 kg to 0 ... 20 t |
Compression | 0.1 % | rational. 2 mV/V ±0.25 % [10 VDC, max. 15 VDC] |
|
![]() |
ACDES Low profile load cell |
0 ... 50 kg to 0 ... 2 t |
Tension/ Compression | 0.1 % | rational. 2 mV/V ±0.25 % [10 VDC, max. 15 VDC] |
|
![]() |
ACMM Miniature compression load cell |
0 ... 10 N to 0 ... 1 kN |
Compression | 1 % | 0.7 ... 1.2 mV/V [5 VDC] |
|
![]() |
ALF216 Load cell |
0 ... 5 kN to 0 ... 40 kN |
Compression | 0.5 % | 1.2 mV/V or rational. 1.0 mV/V ±0.5 % [10 VDC, max. 20 VDC] |
|
![]() |
ALF218 Column load cell |
0 ... 100 kN to 0 ... 400 kN |
Compression | 0.5 % | 2.3 mV/V or rational. 2.0 mV/V ±0.5 % [10 VDC, max. 20 VDC] |
|
![]() |
ALF250 | ALF251 Miniature diaphragm load cell |
0 ... 100 N to 0 ... 3.2 kN |
Tension/ Compression | 0.5 % | ALF250: 1.6 mV/V or rational. 1.0 mV/V ±0.5 % [5 VDC, max. 10 VDC] ALF251: 1.6 mV/V [10 VDC] rational. 1.0 mV/V ±0.5 % [10 VDC] |
|
![]() |
ALF255 Miniature diaphragm load cell |
0 ... 100 N to 0 ... 6.4 kN |
Tension/ Compression | 0.1 % | 2.2 mV/V or rational. 2.0 mV/V ±0.1 % [10 VDC] |
|
![]() |
ALF259 Button load cell |
0 ... 250 N to 0 ... 1000 N |
Tension/ Compression | 0.5 % | 1.6 mV/V or rational. 1.0 mV/V ±0.5 % [5 VDC, max. 10 VDC] |
|
![]() |
ALF308 Axial load cell |
0 ... 200 N to 0 ... 2500 N |
Tension/ Compression | 0.3 % or 0.35 % |
1.2 mV/V [10 VDC] rational. 1.0 mV/V ±0.5 % [10 VDC] |
|
![]() |
AUMI Miniature load cell |
0 ... 1 N to 0 ... 20 kN |
Tension/ Compression | 0.5 % | rational. 1 mV/V ±1 % [5 VDC] rational. 2 mV/V ±1 % [10 VDC], depending on range |
|
![]() |
AUMM | AUMMA Miniature load cell |
0 ... 10 N to 0 ... 2 kN |
Tension/ Compression | 1 % | 0.7 ... 1.2 mV/V [5 VDC] |
|
![]() |
ELAF Low-cost miniature load cell |
0 ... 50 N to 0 ... 25 kN |
Compression | 0.25 % | 20 mV/V [5 VDC] 0.5 ... 4.5 V ratiometric [5 VDC] |
|
![]() |
ELFF Miniature load cell |
0 ... 50 N to 0 ... 500 N |
Tension/ Compression | 0.5 % | 20 mV/V [5 VDC] 0.5 ... 4.5 V ratiometric [5 VDC] |
|
![]() |
ELHM Miniature load cell |
0 ... 2.5 kN to 0 ... 50 kN |
Tension/ Compression | 0.3 % | 2 mV/V [5 VDC] |
|
![]() |
ELPF Miniature load cell |
0 ... 50 N to 0 ... 2.5 kN |
Tension/ Compression | 0.25 % | 20 mV/V [5 VDC] 0.5 ... 4.5 V ratiometric [5 VDC] |
|
![]() |
ELWF Miniature load cell |
0 ... 25 N to 0 ... 10 kN |
Compression | 1 % | 20 mV/V [5 VDC] 6 mV/V [5 VDC] 0.5 ... 4.5 V ratiometric [5 VDC] |
|
| LFH-71E Miniature compression load cell |
0 ... 1 kN to 0 ... 50 kN |
Compression | 1 % | 1.5 ... 2.5 mV/V [5 VDC] | add to notepad |
| Model | Measurement Range | Tension/ Compression | Accuracy | Output [Supply Voltage] | Datasheet | |
![]() |
41E Compact all-purpose precision pressure transducer |
0 ... 20 N to 0 ... 200 kN |
Tension/ Compression | 0.1 % or 0.2 % |
rational. 2 or 3 mV/V ±0.5 % [10 VDC] 0 ... 5 V , ±5 V [11 ... 28 VDC] 0 ... 10 V , ±10 V [15 ... 28 VDC] 4 ... 20 mA 3L [22 ... 32 VDC] 4 ... 20 mA 2L [15 ... 40 VDC] |
|
![]() |
ACSDH Low profile load cell |
0 ... 30 t to 0 ... 100 t |
Compression | 0.1 % | rational. 3 mV/V ±0.3 % [10 VDC, max. 15 VDC] |
|
![]() |
ADSCK Low profile load cell |
0 ... 1 t to 0 ... 20 t |
Tension/ Compression | 0.05 % | rational. 3 mV/V ±0.3 % [10 VDC, max. 15 VDC] |
|
![]() |
ADSCS Low profile load cell |
0 ... 200 kg to 0 ... 1 t |
Tension/ Compression | 0.05 % | rational. 3 mV/V ±0.3 % [10 VDC, max. 15 VDC] |
|
![]() |
ALF225 High load ultra low profile load cell |
0 ... 50 kN and 0 ... 100 kN |
Compression | 0.5 % | 2.3 mV/V rational. 2.0 mV/V ±0.5 % [10 VDC] |
|
![]() |
ALF252 Pancake load cell |
0 ... 1 kN to 0 ... 10 kN |
Tension/ Compression | 0.1 % | 1.6 mV/V rational. 1.5 mV/V ±0.5 % [10 VDC, max. 20 VDC] |
|
![]() |
ALF254 Fatigue rated load cell |
0 ... 25 kN to 0 ... 200 kN |
Tension/ Compression | 0.1 % |
2.1 mV/V rational. 2 mV/V ±0.5 % [10 VDC, max. 20 VDC] 4 ... 20 mA 2L [20 ... 36 VDC] 4 ... 20 mA 3L [11.5 ... 12.5 VDC] 4 ... 20 mA 3L [15 ... 30 VDC] ±10 V [14 ... 27 VDC] |
|
![]() |
ALF302 Pancake load cell |
0 ... 5 kN to 0 ... 50 kN |
Compression | 0.5 % | rational. 2.0 mV/V ±0.5 % [10 VDC] |
|
![]() |
ALF303 OEM load cell |
0 ... 20 kN and 0 ... 40 kN |
Compression | 2 % | 2 mV/V rational. 2.0 mV/V ±1 % [10 VDC] |
|
![]() |
ALF306 Disc-shaped load cell |
0 ... 50 N to 0 ... 10 kN |
Compression | 0.3 % or 0.5 % |
1.2 or 2.2 mV/V rational. 1.0 or 2.0 mV/V ±0.5 % [10 VDC] depending on range |
|
![]() |
ALF318 Pancake load cell |
0 ... 1 kN to 0 ... 500 kN |
Tension/ Compression | 0.1 % | 2.1 mV/V rational. 2.0 mV/V ±0.1 % [10 VDC, max. 20 VDC] |
|
| Model | Measurement Range | Tension/ Compression | Accuracy | Output [Supply Voltage] | Datasheet | |
![]() |
ACWFK Center hole type load cell |
0 ... 10 t to 0 ... 200 t |
Compression | 1 % | rational. 1.0 mV/V ±0.3 % [10 VDC, max. 15 VDC] |
|
![]() |
ALF202 Donut load cell |
0 ... 10 kN to 0 ... 200 kN |
Compression | 0.1 % |
1.2 mV/V or rational. 1,0 mV/V ±0.5 % [10 VDC, max. 20 VDC] 4 ... 20 mA 2L [20 ... 36 VDC] 4 ... 20 mA 3L [11.5 ... 12.5 VDC] 4 ... 20 mA 3L [15 ... 30 VDC] ±10 V [14 ... 27 VDC] |
|
![]() |
ALF203 Donut load cell |
0 ... 400 kN and 0 ... 800 kN |
Compression | 0.5 % |
1.2 mV/V or rational. 1.0 mV/V ±0.5 % [10 VDC, max. 20 VDC] 4 ... 20 mA 2L [20 ... 36 VDC] 4 ... 20 mA 3L [11.5 ... 12.5 VDC] 4 ... 20 mA 3L [15 ... 30 VDC] ±10 V [14 ... 27 VDC] |
|
![]() |
ALF205 Donut load cell |
0 ... 1000 kN and 0 ... 2000 kN |
Compression | 0.5 % | 1.2 mV/V [10 VDC, max. 20 VDC] |
|
![]() |
ALF207 Load washer |
0 ... 10 kN to 0 ... 200 kN |
Compression | 2 % | 1.3 mV/V [10 VDC] rational. 1.0 mV/V ±1.0 % [10 VDC] |
|
![]() |
ALF209 Donut load cell |
0 ... 1000 kN to 0 ... 4000 kN |
Compression | 1 % | 1.0 mV/V [10 VDC] |
|
![]() |
ALF210 Donut load cell |
0 ... 7.5 kN to 0 ... 50 kN |
Compression | 0.5 % | 1.2 mV/V or rational. 1.0 mV/V ±0.5 % [10 VDC, max. 20 VDC] |
|
|
ALF313 Low-profile donut load cell |
0 ... 10 kN to 0 ... 200 kN |
Compression | 0.5 % | 1.3 mV/V [10 VDC] rational. 1.0 mV/V ±0.5 % [10 VDC] |
|
| Model | Measurement Range | Tension/ Compression | Accuracy | Output [Supply Voltage] | Datasheet | |
![]() |
ADBBP | ADBBPS S-beam load cell |
0 ... 20 kg to 0 ... 5 t |
Tension/ Compression | 0.03 % | rational. 3 mV/V ±0.5 % [10 VDC, max. 15 VDC] |
|
![]() |
ATLC Tension load cell |
0 ... 500 kg to 0 ... 5 t |
Tension | 0.03 % | rational. 1.5 mV/V ±0.25 % [10 VDC, max. 15 VDC] |
|
| Model | Measurement Range | Tension/ Compression | Accuracy | Output [Supply Voltage] | Datasheet | |
![]() |
ABTA Pillow block type load cell |
0 ... 5 kN to 0 ... 50 kN |
Tension/ Compression | 0.2 % | rational. 1 mV/V ±0.25 % [10 VDC, max. 15 VDC] |
|
![]() |
ACDBH Double ended shear beam load cell |
0 ... 5 t to 0 ... 25 t |
Tension/ Compression | 0.03 % | rational. 3 mV/V ±0.25 % [10 VDC, max. 15 VDC] |
|
![]() |
ALF238 Binocular bending beam |
0 ... 50 N to 0 ... 300 N |
Tension/ Compression | 0.05 % | 2.2 mV/V or rational. 2.0 mV/V ±0.1 % [10 VDC] |
|
![]() |
ALF268 Shear beam load cell |
0 ... 5 kN to 0 ... 160 kN |
Tension/ Compression | 0.1 % | rational. 2.0 mV/V ±0.1 % [10 VDC] |
|
![]() |
ALF301 Low range stylus load cell |
0 ... 1 N and 0 ... 3 N |
Tension/ Compression | 0.1 % | 1.0 mV/V or rational. 0.8 mV/V ±0.5 % [10 VDC] |
|
![]() |
ALS100 Bending beam load cell |
0 ... 0,5 N to 0 ... 125 N |
Tension/ Compression | 0.05 % | 1.0 mV/V [10 VDC, max. 15 VDC] |
add to notepad |
![]() |
AOBU Single point bending beam load cell |
0 ... 3 kg to 0 ... 250 kg |
Tension/ Compression | 0.02 % | 1 mV/V [10 VDC, max. 15 VDC] 2 mV/V [10 VDC, max. 15 VDC] 2.2 mV/V [10 VDC, max. 15 VDC] depending on range |
|
![]() |
AOBUH Bending beam load cell |
0 ... 5 kg to 0 ... 100 kg |
Tension/ Compression | 0.02 % | 2 mV/V [10 VDC, max. 15 VDC] |
|
![]() |
AOBUX Single point load cell |
0 ... 50 kg to 0 ... 500 kg |
Tension/ Compression | 0.02 % | 2 mV/V [10 VDC, max. 15 VDC] |
|
![]() |
AOSBH Shear beam load cell |
0 ... 200 kg to 0 ... 10 t |
Tension/ Compression | 0.03 % | rational. 3 mV/V ±0.25 % [10 VDC, max. 15 VDC] |
|
![]() |
AOSBK Shear beam load cell |
0 ... 200 kg to 0 ... 10 t |
Tension/ Compression | 0.03 % | rational. 3 mV/V ±0.25 % [10 VDC, max. 15 VDC] |
|
![]() |
AOSW Shear beam load cell |
0 ... 1 t to 0 ... 10 t |
Tension/ Compression | 0.03 % | rational. 2 mV/V ±0.25 % [10 VDC, max. 15 VDC] |
|
| Model | Measurement Range | Tension/ Compression | Accuracy | Output [Supply Voltage] | Datasheet | |
![]() |
ABMD Weigh module for hopper and tank |
0 ... 5 t to 0 ... 15 t |
Compression | 0.03 % | rational. 3 mV/V ±0.25 % rational. 2 mV/V ±0.25 % [10 VDC, max. 15 VDC] depending on model |
|
![]() |
ACDUP Weigh module for vehicle scales |
0 ... 15 t and 0 ... 25 t |
Compression | 0.02 % | rational. 2 mV/V ±0.15 % [10 VDC, max. 15 VDC] |
|
![]() |
ACDBM Weigh module for vehicle scales |
0 ... 5 t to 0 ... 15 t |
Compression | 0.03 % | rational. 2.0 mV/V ±0.25 % [10 VDC, max. 15 VDC] |
|
![]() |
ABMK Weigh module for hoppers, reservoires and open basins |
0 ... 200 kg to 0 ... 5 t |
Compression | 0.03 % | rational. 3 mV/V ±0.25 % rational. 2 mV/V ±0.25 % [10 VDC, max. 15 VDC] depending on model |
|
| Model | Measurement Range | Tension/ Compression | Accuracy | Output [Supply Voltage] | Datasheet | |
![]() |
ACSDK Double ended shear beam load cell |
0 ... 200 kg to 0 ... 30 t |
Tension/ Compression |
0.5 % | up to 500 kg: rational. 0.5 mV/V ±0.2 % 1 t and more: rational. 1.5 mV/V ±0.2 % [10 VDC, max. 20 VDC] |
|
![]() |
LMP Load measuring pin |
0 ... 500 kg to 0 ... 1500 t |
Tension | 0.5 % | 1.5 mV/V [10 VDC, max. 15 VDC] with integral electronics available: 4 ... 20 mA, 0 ... 5 V , 0 ... 10 V , RS-485 |
add to notepad |
![]() | SHK-B Shackle load cell |
0 ... 1 t to 0 ... 400 t |
Tension | 1.0 % | 1.5 mV/V [10 VDC, max. 15 VDC] 4 ... 20 mA 2L [7.5 ... 28 VDC] 4 ... 20 mA 3L [13 ... 28 VDC] 0 ... 5 V [8.5 ... 14 VDC] 0 ... 10 V [13 ... 30 VDC] |
add to notepad |
![]() |
SHK-D Shackle load cell |
0 ... 1 t to 0 ... 35 t |
Tension | 1.0 % | 1.5 mV/V [10 VDC, max. 15 VDC] 4 ... 20 mA 2L [7.5 ... 28 VDC] 4 ... 20 mA 3L [13 ... 28 VDC] 0 ... 5 V [8.5 ... 14 VDC] 0 ... 10 V [13 ... 30 VDC] |
add to notepad |
| Model | Measurement Range | Tension/ Compression | Accuracy | Output [Supply Voltage] |
Datasheet | |
![]() |
70025 Triaxial force sensor |
±5000 lb (approx. ±22 kN) |
Tension/ Compression | 0.1 % | 2.0 mV/V [20 VDC] |
|
![]() |
70048 Triaxial load cell |
±400 lb to ±50000 lb (approx. ±1.8 kN to ±222 kN) |
Tension/ Compression | 1 % | 1.5 mV/V [15 VDC] |
|
![]() |
ALF232 | ALF233 Dual or triple axis force transducer |
±100 N to ±5 kN |
Tension/ Compression | 0.5 % | 1.2 mV/V [10 VDC] |
|
![]() |
ALF307 Triple axis force transducer |
±10 kN and ±20 kN |
Tension/ Compression | 0.3 % | 1.5 mV/V [10 VDC] |
|
![]() |
ALF310 Axial force and torque transducer |
±50 N and ±2 Nm |
Tension/ Compression | 0.05 % | 0.6 mV/V rational. 0.5 mV/V ±0.5 % [10 VDC] |
|
![]() |
ALF314 Dual axis load cell |
±2 kN to ±10 kN |
Tension/ Compression | 0.1 % | 1.2 mV/V [10 VDC] |
|
| Model | Measurement Range | Tension/ Compression | Accuracy | Output [Supply Voltage] | Datasheet | |
![]() |
10118 Brake pedal force sensor |
0 ... 25 lb to 0 ... 400 lb (approx. 0 ... 111 N to 0 ... 1.8 kN) |
Compression | 0.1 % | 2.0 mV/V [20 VDC] |
|
![]() |
10293 System for measuring window and sunroof force |
0 ... 200 N | Compression | 0.1 % | 2 mV/V [20 VDC] as system via PMAC2000 |
|
![]() |
50006 Shift knob load cell |
0 ... 50 lb to 0 ... 200 lb (approx. 0 ... 222 N to 0 ... 890 N) |
Tension/ Compression | 0.25 % | 2.0 mV/V [20 VDC] |
|
![]() |
90061 Mobile welding force measuring system |
0 ... 300 lb to 0 ... 10000 lb (approx. 1.3 kN to 44 kN) |
Compression | 0.5 % | 0 ... 1 V [Battery Type AA] |
|
![]() |
ALF304 Brake pedal force sensor |
0 ... 2500 N | Compression | 0.05 % | rational. 2.0 mV/V ±0.1 % [10 VDC, max. 20 VDC] |
|
![]() |
ALF305 Seat belt tension load cell |
0 ... 16 kN | Tension | 3 % | 1.5 mV/V [10 VDC] |
|
|
ALF319 Hand brake load cell |
0 ... 1 kN | Compression | 0.05 % | rational. 1.0 mV/V ±0.2 % [10 VDC] |
|
|
![]() |
ALF321 Gear shift load cell |
±200 N | Tension/ Compression | 0.5 % | 1.0 mV/V [10 VDC] |
|
![]() |
ALF322 Accelerator pedal force load cell |
0 ... 250 N | Compression | 0.05 % | rational. 1.0 mV/V ±0.1 % [10 VDC, max. 20 VDC] |
|
![]() |
ALF323 Clutch pedal force load cell |
0 ... 1 kN | Compression | 0.05 % | rational. 1.0 mV/V ±0.1 % [10 VDC, max. 20 VDC] |
|
![]() |
ALF325 High accuracy web tension loadcell |
0 ... 50 N to 0 ... 500 N |
Compression | 0.03 % | 1.2 mV/V or rational. 1.0 mV/V ±0.1 % [10 VDC] |
|
![]() |
APSA Ultra-flat platform scale |
0 ... 50 kg to 0 ... 300 kg |
Compression | 0.1 % | 2 mV/V [10 VDC, max. 15 VDC] 4 ... 20 mA [10 VDC, max. 15 VDC] |
|
![]() |
AWLFN2 Rope tension load cell |
0 ... 500 kg to 0 ... 10 t per rope |
Tension | 1.0 % | 1.0 mV/V [10 VDC, max. 15 VDC] |
|
![]() |
SS2 | SS3 Ultra Low Force Load Cell |
±30 g and 0 ... 60 g |
Tension/ Compression | 0.5 % | 12 mV/V [10 VDC, max. 15 VDC] |
|
![]() |
TLL Tension shackle load cell |
0 ... 5 t to 0 ... 100 t |
Tension | 0.25 % | 1.5 mV/V [10 VDC, max. 15 VDC] |
add to notepad |
![]() |
TOG Rope tension load cell |
0 ... 750 kg to 0 ... 9500 kg |
Tension | 0.2 % | 1.0 mV/V [10 VDC, max. 15 VDC] with integral electronics available |
add to notepad |