Pressure / Differential Pressure – tactile Pressure Sensors – Load / Force – Torque – Linear Displacement – Rotary Position – Inclination / Tilt – Acceleration – Vibration – Rate – Amplifier and Signal Conditioner – Telemetry – Datalogger / Data Aquisition |
|
AV3032 Series Miniature Vibration Sensor
|
|
** IEPE = internal electronics piezoelectric
Specifications AV3032x
|
Performance:
|
|
|
|
Model |
x = A |
x = A1 |
|
Sensitivity, ±10% *1 |
10 mV/g |
5 mV/g |
|
Range F.S. (for ±5 V out) |
±500 g |
±1000 g |
|
Frequency response: |
|
|
|
±10 % |
1 … 10000 Hz |
|
|
±3 dB |
0.66 … 12000 Hz |
|
|
Mounted resonant frequency, nom. |
40 kHz |
|
|
Equivalent electrical noise (resolution) |
0.007 g eff. |
|
|
Amplitude non-linearity, max. *2 |
2.0 % F.S |
|
|
Transverse sensitivity, max. |
5 % |
|
|
Strain sensitivity |
0.001 g per microstrain (1 µm/m) at 250/µs |
|
*1 Measured at 1 g rms at 100 Hz per ISA RP 37.2
*2 Zero based best fit st. line method
|
Physical:
|
|
|
Model |
x = A / A1 |
|
Weight, less cable |
approx. 1.5 gram |
|
Weight, including cable |
approx. 5.6 gram |
|
Size (hex x height) |
approx. 6.4 x 7.1 mm (0.25 x 0.28 inch) |
|
Mouting provision |
adhesive mount |
|
Electrical connection |
integr.cable (length approx. 45 cm (18 inches)) with coaxial connector (10-32, UNF-2A, Jack) |
|
Material case/cap |
Titanium |
|
Element type |
quartz shear |
|
Environmental:
|
|
|
|
Model |
x = A |
x = A1 |
|
Maximum vibration |
1000 g rms |
1500 g rms |
|
Maximum shock |
1500 g peak |
2000 g peak |
|
Temperature range |
-50 … +120 °C (-60 … +250 °F) |
|
|
Thermal coefficient of sensitivity |
0.11 %/°C (0.06 %/°F) |
|
|
Sealing |
epoxy / welded |
|
|
Electronical
|
|
|
Model |
x = A / A1 |
|
Excitation current range |
2 … 20 mA |
|
Excitation (compliance) voltage range |
+20 … +30 VDC |
|
Output impedance, nom. |
100 Ω |
|
Output Bias voltage, ±2 V |
10 VDC |
|
Discharge time constant, min. |
0.5 s |
|
Output signal polarity |
positive going for acceleration towards top |
Note!
Power only with IEPE power unit from ALTHEN or other, compatible
constant current type power unit.
If power is applied with
a
non-compatible power unit,
e.g. without current limiting, the internal amplifier
will be destroyed immediately.
A calibration certificate traceable to NIST is supplied with each
instrument.
Dimensions
|
|
|
|
|
|
|
|
|
!1 |
Do not mount on this surface! |
|
S |
10-32 connector |
|
M |
Mounting surface |
|
d1* |
hex 6.4 mm (0.250 inch) |
|
d2* |
457 mm ±12.7 mm (18.00 inch ±0.50 inch) |
|
d3* |
7.1 mm (0.28 inch) |
|
d4* |
Diameter 5.99 mm (0.236 inch) |
*all dimensions are approx. values.
Our policy is to improve specification of our products continuously, so technical and production details can be changed without any notice.
|
|
|
|
|