- add to Notepad
- HTML-Datasheet
- no Datasheet available
- Productdetails as PDF
Triaxial Vibration Sensor AV3293M1 - vibration measurement from ALTHEN Triaxial Vibration Sensor in IEPE Technology
Specifications
| Dynamic specification | ||
|---|---|---|
|
Sensitivity, ±10 % [1]: |
50 mV/(m/s²) |
500 mV/g |
|
Range: |
±69 m/s² peak |
±7 g peak |
|
Linearity [2]: |
1 % F.S. |
|
|
Frequency Range, ±10 %: |
0.25 … 4000 Hz |
|
|
Resonant Frequency, nom.: |
>15 kHz |
|
|
Transverse sensitivity, max.: |
6 % |
|
| Electrical specification | SI | engl. | |
|---|---|---|---|
|
Supply voltage: |
+18 … +30 VDC |
||
|
Constant current supply [3]: |
2 … 20 mA |
||
|
Residual noise (rms): |
0.002 m/s² |
0.0002 g |
|
|
Spectral noise (rms): |
|||
|
1 H |
294 (μm/s²)/√Hz |
30 μg/√Hz |
|
|
Output impedance, typ.: |
100 Ω |
||
|
Bias output voltage: |
11 … 13 VDC |
||
|
Discharge time constant: |
1.0 … 1.5 s |
||
| Environmental specification | SI | engl. |
|---|---|---|
|
Operating temperature: |
-50 °C … +85 °C |
-60 °F … +185 °F |
|
Vibration limit: |
490 m/s² |
50 g peak |
|
Destruction limit: |
9810 m/s² |
1000 g peak |
|
Electromagnetic sensitivity at 100 Gauss: |
0.0009 (m/s²)/Gauss |
0.00009 g/Gauss |
|
Strain sensitivity, max.: |
0.02 (m/s²)/με |
0.002 g/με |
|
Environmental seal: |
hermetic |
|
| Physical data | SI | engl. |
|---|---|---|
|
Sensing element design: |
Ceramic Sensing element in shear mode |
|
|
Weight, approx.: |
8.8 gram |
0.308 oz |
|
Case material: |
Titanium (Ti-6 AL-4V) |
|
|
Case isolation: |
Case grounded |
|
|
Connector Type [4]: |
4-pin, ¼-28 |
|
|
Connector material: |
Titanium (Ti-6 AL-4V) |
|
Notes
- Measured at 100 Hz, 1 g rms per ISA RP 37.2
- Linearity is % of specified full scale (or any lesser full scale range), zero-based best fit straight line method.
- Do not apply power to this device without current limiting, 20mA max, to do so will destroy the integral IC amplifier.
- Glass to metal seal connector. Mates with ALTHEN cable model AV6811Axx or AV6824Axx (xx = length in feet)
Accessories
Supplied accessories:
- Mounting Stud with 5-40 UNF to metric thread
- Accredited Calibration Certificate (ISO 17025)