? Explanation
  • add to Notepad
  • HTML-Datasheet
  • no Datasheet available
  • Productdetails as PDF

Triaxial Vibration Sensor AV3293M1 - vibration measurement from ALTHEN Triaxial Vibration Sensor in IEPE Technology

Triaxial Vibration Sensor AV3293M1

Specifications

Dynamic specification

Sensitivity, ±10 % [1]:

50 mV/(m/s²)

500 mV/g

Range:

±69 m/s² peak

±7 g peak

Linearity [2]:

1 % F.S.

Frequency Range, ±10 %:

0.25 … 4000 Hz

Resonant Frequency, nom.:

>15 kHz

Transverse sensitivity, max.:

6 %

Electrical specification SI engl.

Supply voltage:

+18 … +30 VDC

Constant current supply [3]:

2 … 20 mA

Residual noise (rms):

0.002 m/s²

0.0002 g

Spectral noise (rms):

   
 

1 H
10 Hz
100 Hz
1000 Hz
10000 Hz

294 (μm/s²)/√Hz
69 (μm/s²)/√Hz
88 (μm/s²)/√Hz
9.8 (μm/s²)√Hz
9.8 (μm/s²)√Hz

30 μg/√Hz
7 μg/√Hz
9 μg/√Hz
1 μg/√Hz 1 μg/√Hz

Output impedance, typ.:

100 Ω

Bias output voltage:

11 … 13 VDC

Discharge time constant:

1.0 … 1.5 s

Environmental specification SI engl.

Operating temperature:

-50 °C … +85 °C

-60 °F … +185 °F

Vibration limit:

490 m/s²

50 g peak

Destruction limit:

9810 m/s²

1000 g peak

Electromagnetic sensitivity at 100 Gauss:

0.0009 (m/s²)/Gauss

0.00009 g/Gauss

Strain sensitivity, max.:

0.02 (m/s²)/με

0.002 g/με

Environmental seal:

hermetic

Physical data SI engl.

Sensing element design:

Ceramic Sensing element in shear mode

Weight, approx.:

8.8 gram

0.308 oz

Case material:

Titanium (Ti-6 AL-4V)

Case isolation:

Case grounded

Connector Type [4]:

4-pin, ¼-28

Connector material:

Titanium (Ti-6 AL-4V)

Notes

  1. Measured at 100 Hz, 1 g rms per ISA RP 37.2
  2. Linearity is % of specified full scale (or any lesser full scale range), zero-based best fit straight line method.
  3. Do not apply power to this device without current limiting, 20mA max, to do so will destroy the integral IC amplifier.
  4. Glass to metal seal connector. Mates with ALTHEN cable model AV6811Axx or AV6824Axx (xx = length in feet)

Accessories

Supplied accessories:

  1. Mounting Stud with 5-40 UNF to metric thread
  2. Accredited Calibration Certificate (ISO 17025)