? Explanation
  • add to Notepad
  • HTML-Datasheet
  • no Datasheet available
  • Productdetails as PDF

InnoBeamer® X2 USB Data Acquisition Device for VibroMatrix

Vibration measurement with InnoBeamer X2

Application
The InnoBeamer makes digital real-time vibration measurement easy! It is automatically recognized by the PC and digitizes the sensor signals for the VibroMatrix measurement system. Transferring the sensor signals to the PC is carried out without loss as a permanent data stream.

The InnoBeamer is supplied by PC’s USB host interface and on its part supplies the connected sensors. External power supply is not required, field measurement by means of a notebook is possible without any problems.

The InnoBeamer supports synchronous data acquisition beyond device’s borders. This way, devices can flexibly work alone or be combined to multi-channel systems.

Sensors with integrated data sheet (TEDS) are automatically recognized by the InnoBeamer. All required sensor data is read electronically, operating errors are avoided.

The InnoBeamer is a high-precision measuring instrument in a small format.

Properties

  • Inputs for 2 sensors with IEPE interface as well as 1 r.p.m. sensor
  • Supports intelligent sensors with TEDS
  • Supply of all sensors
  • Data transfer to PC by USB
  • Supplied by USB interface of PC
  • 4 decade input ranges
  • 24 Bit analog-digital-conversion
  • Synchronous measurement with several devices
  • Cases can be interlinked by means of connectors
  • For signals from 0.1 to 40000 Hz

Specifications

Model InnoBeamer X2

Configuration

2x AC analog input, IEPE, TEDS
2x digital trigger input
1x supply photoelectric/contrast scanner
1x optional power supply


AC Analog Input

 

Standard configuration

AC input and IEPE supply

IEPE supply can be switched off

by software

TEDS: internal sensor data sheet is transmitted

yes, acc. to IEEE 1451.4

IEPE power supply for sensor

2.8 mA

IEPE compliance voltage

22 V

Number of channels

2

Input resistance

>1 MΩ

A/D conversion

24 Bit, 96 kHz per channel

Signal frequency (-3 dB)

0.1 ... 40000 Hz

Measuring ranges

±8000, ±800, ±80, ±8 mV

Actual wideband noise

5 μV (0.1 ... 40000 Hz)

Measuring error

<2 %

Connector

BNC


Digital Trigger Input

 

Standard configuration

Input for external phase reference signal

Level

0 … 24 V

Number

2

Switching threshold High-Low

1.5 V

Minimum pulse length

12 μs


Supply for External Sensors (in addition to IEPE)

 

Supply voltage

13.5 V

Supply current

35 mA (150 mA with external supply)


InnoBeamer Characteristics

 

USB standard

2.0 und aufwärts

Synchronous data acquisition of several devices

yes, by synchronisation cable

Supply voltage

5 V via USB cable, optional 10 ... 30 V externally

Supply current

475 mA
(@ 5 V, with 2 IEPE sensors and supply photoelectronic/contrast scanner)

Operating temperature

-20 … +55 °C

Relative humidity

<95 %, without condensation

Dimensions W x H x D

115 x 39 x 105 mm

Mass

350 g