Application

Rotating parts in drives, gears, pumps, fans and many other technical products cause perturbing vibrations. Impulse-like loads, e.g. from a vibratory pile driver in the construction-field, generate problems as well. In numerous vibration standards, for instance DIN 10816, significant vibration parameters are defined for a reliable evaluation of the vibration situation. The InnoPlotters measure these vibration parameters and display their trend for a longer time graphically. Thus, they are especially convenient for longer test sequences. Weak spots in the continuous operation become obvious, the success of counter measures is proven and the compliance with limits is controlled.

Properties

The InnoPlotter is a universal digital strip chart recorder for up to four vibration parameters. It features a memory for 24 hours continuous recording and various display modes. 2 time axes are available for the absolute time and the past time since the start of measuring. Additionally to vibration acceleration, the Pro Version is also able to process vibration velocity and displacement.

The following settings are possible: - Free filter adjustment 0.3 ... 2000 Hz - Up to 26 units, metric and imperial - 6 parameters

2 cursors allow the exact measurement of the data. Therefore, the time bar can be moved and spread manually. But it can also be moved automatically depending on the progress of the measurement. The export of data into other applications as graphic or text is possible without any problems. Saving measured data can be carried out manually or automated. By means of the new messenger function, the InnoPlotter can forward the automatically saved data by e-mail.

Vibration Measurement with InnoPlotter

Technical DataInnoPlotter Pro / InnoPlotter

Modell InnoPlotter Pro InnoPlotter

Signal processing

Filter

Freely adjustable 0.1 ... 40000 Hz **

Time

Freely adjustable 0.1 ... 10 s

Measurands

AC voltage
Vibration acceleration
Vibration velocity
Vibration displacement

AC voltage
Vibration acceleration

Units

V, mV, μV, nV, pV m/s², mm/s², μm/s², nm/s², pm/s², g, mg, μg, dB m/s, mm/s, μm/s, nm/s, pm/s, in/s, dB m, mm, μm, nm, pm, in, dB

V, mV, μV, nV, pV m/s², mm/s², μm/s², nm/s², pm/s², g, mg, μg, dB

Parameters

Instantaneous value, peak value absolute, peak value positive, peak value negative, peak-to-peak value, true RMS

Monitoring

Alarm value freely adjustable, alert value 0 … 100 % of alarm value

Graphical presentation

Number of graphs

1 … 4 per window

Number of limit graphs

0 … 8 per window

Interval Y-axis

0,01 … 24 h

Interval t-axis

1 min … 24 h

Digital channel

Display of the variation in time of the trigger status (switchable, one measuring channel)

Refresh

1 … 4 times per second *

Indicators

Sensor, measuring channel, measurand, parameter, gain, overload, underload

Recommended screen resolution

From 800 x 600 pixels on

Cursors

Presentation

2 lines, optionally freely adjustable by mouse or button

Numeric cursor data

For each cursor as well as difference cursor 2 - cursor 1

Numeric cursor refresh

1 … 4 times per second *

Data export

Controlling

Manually, time triggered, level triggered

Manually, time triggered

Formats

Bitmap, PNG, Enhanced Meta File (EMF), text

Destinations

In clipboard or file

Event messengers

Message to large screen

Single channel: current reading
Single channel: current alarm status
Instrument: current alarm status

Single channel: current reading

Message to radio switching socket

Single channel: current alarm status Instrument: current alarm status

--

Message to digital output

Single channel: current alarm status Instrument: current alarm status

--

Message to e-mail

Time triggered sending of measured data
Level triggered sending of measured data

Time triggered sending of measured data

Miscellaneous

General functions

Hold of measured data after switch-off; Instrument is cloneable

* Centrally managed in the InnoMaster
** Usage with InnoBeamer L2: 0.3 …2000 Hz

Our policy is to improve specification of our products continuously, so technical and production details can be changed without any notice.