1. Althensensors
  2. Capteurs
  3. Capteurs de basculement & d’inclinaison
  4. Systèmes de mesure et de commutation de l'inclinaison
  5. NM1-ISU-IP Tilt Measuring System

NM1-ISU-IP Tilt Measuring System

Single axis tilt measuring system with digital and analog connection


Caractéristiques principales

  • Single Axis Industrial Tilt Measuring System with RS232-Data Interface
  • Supply voltage 22 … 26 VDC
  • Adjustable measuring range up to 360°
  • Accuracy ±0.2°
  • RS232 Data Interface, optionally analogue output 4 … 20 mA)

About the NM1-ISU-IP Tilt Measuring System

The single axis industrial tilt measuring system NM1-ISU is designed for precise tilt measurement in X axis and intended for the side wall mounting. The inclination ranges are selectable via an internal DIP switch. The measuring data are output via a RS232 data interface. Optional an additional scalable analogue output 4… 20 mA is available.

The tilt measuring system is built-in into a robust EMC-safe aluminium die-cast enclosure (IP66), which is suited for applications in rough and industrial environments.

Avez-vous besoin de ce capteur pour votre prochain projet?

Demandez un devis dès aujourd'hui ou laissez vos coordonnées pour recevoir plus d'informations de la part de l'un de nos experts.

Parler à un expert

Faites-le à votre façon

Vous ne trouvez pas exactement ce que vous cherchez ? Nous proposons des capteurs et des systèmes de mesure standard, mais nous pouvons également vous aider à concevoir un capteur sur mesure ou une solution de mesure complète. N'hésitez pas à nous contacter pour obtenir des conseils ou un devis.

Parler à un expert

Spécifications techniques

Spécifications Valeur
Accuracy ±0.2°
Adjustable measuring range Measuring range about internal DIP-Switch ±10°, ±20°, ±30°, ±45°, ±60°, ±90°, ±120°, ±180° Inclination
Data interface/analogue output/ power rating RS232 Data Interface, 4 - 20 mA (Option …-420..-), max. 500 Ohm
Dimensions (w x h x d) 150 x 65 x 36 mm (without EMC-cable gland)
Electrical connection: Standard: 3 m connecting cable (optionally are cable versions up to 10 m available) Type of cable: Unitronic FD CP plus 3 x 2 x 0.25 mm²
Enclosure EMC-safe aluminium die-cast enclosure
Hysteresis ±0.1°
Measuring frequency 0.4 Hz
Power consumption: ca. 3 W
Repeatability ±0.1°
Supply voltage: 22 - 26 VDC, electronics protected against voltage reversal
Temperature error ±0.015°/°C
Temperature, operating -20 to +60 °C
Temperature, storage -20 to +60 °C
Weight Approx. 630 g with 3 m connecting cable, electronics not moulded in casting compound Approx. 1150 g with 10 m connecting cable, electronics not moulded in casting compound

Produits apparentés

Besoin d'autre chose?

NM2-IP2-2L Tilt Measuring System

  • Measuring range ±3° up to ±45° per axis
  • In a compact EMC-safe aluminium enclosure
  • Accuracy ±0.1° to ±0.25°
Datasheet Voir le produit