1. Althensensors
  2. Instrumentation
  3. Amplificateurs de Mesure & Afficheurs
  4. Amplificateurs à jauge de contrainte
  5. SG-AP Strain Gauge Amplifiers

SG-AP Strain Gauge Amplifiers

Single Channel Strain Gauge Amplifier with Aluminium Enclosure


About the SG-AP Strain Gauge Amplifiers

The single channel strain gauge measuring amplifier SG-AP allows the supply and signal evaluation of a transducer with a strain gauge full bridge greater than 300 ohms. Input and output are galvanically isolated. The connection is done in 4-wire technology via a pluggable screw clamp terminal block. For further evaluation standard analogue outputs are available. The measuring amplifier is available in 3 versions with different sensitivity. By means of potentiometer for zero and amplification, a calibration correction can be carried out.

 

Key features SG-AP

  • Supply voltage 10 - 18 VDC / 18 - 30 VDC
  • Analogue output 0 - 10 V / ±10 V
  • Aluminium profile enclosure (IP20)
  • Dimensions (W x H x D) 104 x 55 x 30 mm

Avez-vous besoin de ce capteur pour votre prochain projet?

Demandez un devis dès aujourd'hui ou laissez vos coordonnées pour recevoir plus d'informations de la part de l'un de nos experts.

Parler à un expert

Faites-le à votre façon

Vous ne trouvez pas exactement ce que vous cherchez ? Nous proposons des capteurs et des systèmes de mesure standard, mais nous pouvons également vous aider à concevoir un capteur sur mesure ou une solution de mesure complète. N'hésitez pas à nous contacter pour obtenir des conseils ou un devis.

Parler à un expert

Spécifications techniques

Spécifications Valeur
Analogue output 0 - 10 V, ±10 V, max. 1 mA (short-period short-circuit proof)
Dimension (b x h x d) 104 x 55 x 30 mm
Electrical connection Pluggable screw clamp terminal block
Enclosure Aluminium profile enclosure
Input resistance >3 MΩ
Isolating proof voltage input to output 200 V, higher isolated proof voltage on request
Limit frequency (-3 db) Version -GF10Hz: 10 Hz Version, -GF1kHz: 1 kHz
Max. input sensitivity Version -1: 1 mV/V (Range Potentiometer G: 0.5 - 1.5 mV/V) | Version -2: 2 mV/V (Range Potentiometer G: 1.5 - 2.5 mV/V) | Version -3: 3 mV/V (Range Potentiometer G: 2.5 - 3.5 mV/V)
Non-linearity ±0.05 % FSO
Number of measuring channels 1 (full bridge resistance >300 Ω)
Power consumption 2 W
Strain gauge excitation supply 2.5 VDC, 5 VDC, 10 VDC (±2 %, max. 35 mA)
Supply voltage 10 - 18 VDC, 18 - 30 VDC, electronics protected against reversal voltage
Temperature, operating +10 - +50 °C
Temperature, storage -20 - +60 °C