SG-IP-3L-2P Strain Gauge Amplifiers
Single channel strain gauge amplifier (3-wire) for parallel operating of 2 transducers
About the SG-IP-3L-2P Strain Gauge Amplifiers
The single-channel strain gauge measuring amplifier SG-IP-3L-2P (3-wire technology) allows supply and signal evaluation of up to two transducers with normalized sensitivity and a strain gauge full bridge greater than 300 ohms. For further evaluation a standard analogue output of 4 … 20 mA is available. Input and output are not galvanically isolated. The measuring amplifier is built-in into a robust EMC die-cast aluminium enclosure (IP65) which is suited for applications in rough and industrial environments. The amplification can be adapted by an internal precision resistance.
The potentiometers Z (zero) and G (gain), which are accessible after removing the enclosure cover, allow a calibration correction.
Key features SG-IP-3L-2P
- Supply voltage 22 - 26 VDC (no galvanic isolation)
- Analogue output 4 - 20 mA
- EMC aluminium die-cast enclosure (IP65)
- Dimensions (W x H x D) 100 x 100 x 60 mm
Avez-vous besoin de ce capteur pour votre prochain projet?
Demandez un devis dès aujourd'hui ou laissez vos coordonnées pour recevoir plus d'informations de la part de l'un de nos experts.
Téléchargements de produits
Faites-le à votre façon
Vous ne trouvez pas exactement ce que vous cherchez ? Nous proposons des capteurs et des systèmes de mesure standard, mais nous pouvons également vous aider à concevoir un capteur sur mesure ou une solution de mesure complète. N'hésitez pas à nous contacter pour obtenir des conseils ou un devis.
Parler à un expertSpécifications techniques
Spécifications | Valeur |
---|---|
Analogue output | 4 - 20 mA, 500 Ω max. |
Dimensions (w x h x d) | 100 x 100 x 60 mm |
Electrical connection | EMC cable gland on internal terminal block |
Enclosure | EMC aluminium die-cast enclosure (IP65) |
Input resistance | >3 MΩ |
Limit frequency (-3 db) | 1 kHz |
Max. input sensitivity | 100 mV/V at 10 VDC excitation supply |
Non-linearity | ±0.05 % FSO |
Number of measuring channels | 1 (full bridge resistance >300 Ω) Supply |
Power consumption | 4 W max. |
Strain gauge excitation supply | 10 VDC |
Temperature, operating | 0 to +50 °C |
Temperature, storage | -20 to +60 °C |
Voltage | 22 - 26 VDC |
Weight | 525 g |