GLET-SU Module
Active modular enclosure with voltage output
About the GLET-SU Module
Active modular enclosure for active transducer/sensor with voltage output
Fig.: Model GLET-SU2K-BNC/B514-BI5, 2 Channels, BNC
Active modular enclosure for wiring of one or two active transducers / sensors with voltage output in 3-wire technology in connection with a datalogger.
1-Channel Models:
- GLET-SU-BA2/B514-BI5 for data loggers of series GL2xx, GL8xx
- (Graphtec Midi Logger GL240)
- (Graphtec Midi Logger GL840-M & GL840-WV)
- GLET-SU-BNC/B514-BI5 for data loggers of series GL9xx, GL2000
2-Channel Models:
- GLET-SU2K-BA2/B514-BI5 for data loggers of series GL2xx, GL8xx
- (Graphtec Midi Logger GL240)
- (Graphtec Midi Logger GL840-M & GL840-WV)
- GLET-SU2K-BNC/B514-BI5 for data loggers of series GL9xx, GL2000
Accessories for Models with BNC
KA-BNC-iso-sw-0.5m
BNC safety connection cable with 2 straight BNC connectors
- material: PVC
- rating: 1000 V, CAT II (600 V CAT III)
- cable length: 0.5 m
- color: black
Avez-vous besoin de ce capteur pour votre prochain projet?
Demandez un devis dès aujourd'hui ou laissez vos coordonnées pour recevoir plus d'informations de la part de l'un de nos experts.
Téléchargements de produits
Faites-le à votre façon
Vous ne trouvez pas exactement ce que vous cherchez ? Nous proposons des capteurs et des systèmes de mesure standard, mais nous pouvons également vous aider à concevoir un capteur sur mesure ou une solution de mesure complète. N'hésitez pas à nous contacter pour obtenir des conseils ou un devis.
Parler à un expertSpécifications techniques
Spécifications | Valeur |
---|---|
Analog output signal | 0 ... 5/10 V |
Connector for transducer | 5-pin connector (Binder, supplied with mating connector) |
Dimension without connections (wxhxd) | approx. 45 x 115 x 90 mm |
Electrical connection analog output to datalogger | GLET-SU(2K)-BA2/B514-BI5: 2 mm jack, GLET-SU(2K)-BNC/B514-BI5: BNC |
Enclosure | desktop |
Environmental sealing | IP20 |
Input signal | 0 ... 5/10 V 3-wire |
Operating temperature range | 0 ... +50 °C |
Supply voltage | 24 VDC ±5 % * |
Transducer excitation | 18 VDC (max. 50 mA) |
Produits apparentés
Besoin d'autre chose?
GRAPHTEC GL240 Compact Data Logger
- Measuring Ranges: Voltage, Temperature, Humidity
- Measuring Channels: up to 10
- Resolution: 16 bit
GRAPHTEC GL840-M Multichannel Data Logger
- Measuring Ranges: Voltage, Temperature, Humidity, GL100 Sensors
- Measuring Channels: up to 200
- Resolution: 16 bit
GRAPHTEC GL840-WV Multichannel Data Logger
- Measuring Ranges: Voltage, Temperature, Humidity, GL100 Sensors
- Measuring Channels: up to 200
- Resolution: 16 bit