1. Althensensors
  2. Instrumentation
  3. Amplifiers & indicators
  4. Strain gauge amplifiers
  5. TD-SC1 D/A Load Cell Signal Conditioner

TD-SC1 D/A Load Cell Signal Conditioner

Thin, lightweight signal conditioner for strain gauge transducers


Key features

  • Sampling of 20,000 times/second by high-speed CPU
  • Setting by PC via USB connection
  • Thin and light weight compact design
  • Compliant with CE & UKCA marking and UL standards
  • Automates calibration

About the TD-SC1 D/A Load Cell Signal Conditioner

The TD-SC1 is a thin, lightweight signal conditioner for strain gauge transducers. This converts a minute
signal from a transducer into information required for control and outputs it. In recent years, the introduction of IoT in production factories has accelerated rapidly. With the demand for improved productivity through centralized
management, the load cell signal conditioner TD-SC1 series, which is equipped with various functions as standard and realizes high cost effectiveness, meets that need.

Features of the TD-SC1 D/A Load Cell Signal Conditioner

  • Fastest in Class
    Sampling of 20,000 times/second by high-speed CPU

  • Easy to Use
    Setting by PC via USB connection (Available a simple calibration function on the main unit)

  • Thin andLightweight
    Compact design (W30 x H85 x D110mm) + lightweight (210g)

  • Safety Standard
    Compliant with CE & UKCA marking and UL standards that can be used worldwide

  • Easy and Convenient
    Supports the plug-and-play function “TEDS” that automates calibration

  • Maintenance
    Load cell overload is notified by Status LED

  • Selectable Network
    RS-485, CC-LINK*, EtherNet/IP™
    * Supporting various fieldbuses
    * Under planning.

Do you need this sensor for your next project?

Request a quotation today or leave your details to recieve more information from one of our experts.

Talk to an expert

Have it your way

Not exactly what you’re looking for? We offer standard sensors but can also help you with a tailor-made sensor or a complete measuring solution. Please contact us for advice or budgetary pricing.

Talk to an expert

Technical Specifications

Specification Value
A/d conversion 24-bit, 20000 times per second
Applicable standards CE marking, UKCA marking, FCC (Class A), UL61010-1
Bridge voltage DC 5V / 10V ±10% (30mA current maximum, remote sense can be used)
Control input/ output signal Input signal: Hold, Digital zero, Clear (Photocoupler Insulation) / Output signal: Load judgment (HI/OK/LO), NPN open collector (Photocoupler Insulation) / USB Serial: Main unit setting by dedicated application.
Digital filter OFF/3/10/30/100/300/1000Hz (–6dB/oct)
Display Status display by LED on the front of the main unit
Equivalent input /teds Calibration range 0.05mV/V to 5.0mV/V / Calibration precision Within 0.1% F.S. (when using 1m standard TEAC Ø8, 6-core shielded cable with 350Ω impedance, 10V BV and 5mV/V setting)
External dimensions (w×h×d) Approx. 30 × 85 × 110mm (without protrusions)
Hold function Sampling, Peak, Bottom, Zone definition (Peak, Bottom)
How to install Support for 35mm wide top hat type rails (DIN rail mounting)
Moving average OFF / 2 to 2048 times
Operating temperature range 0℃ to 40℃
Options AC adapter (AC100 to 240V, compliant to the safety standards of Japan and North America)
Output TD-SC1 (D/A) Voltage: 0 – ±10V Current: 4 – 20mA / TD-SC1 (485) A+, B – (Photocoupler Insulation), TRM, SG
Output TD-SC1 (E/IP) P1, P2 / TD-SC1 (CCL) DA, DB (isolated from main unit circuits using a photocoupler), DG, SLD
Power supply Ratings: 24V DC ±10% 7W
Precision Linearity: Within 0.01%F.S. +1 digit (when input is 5mV/V) / Zero drift: Within 0.5μV/ºC (Input conversion value) / Gain drift: Within ±0.005% F.S/ºC
Signal input range ±5.0mV/V
Storage temperature range –20℃ to 60℃
Teds function IEEE1451.4 class 2 mix mode interface / Loading, Rewriting, Restoring
Weight Approx. 210g