SG-IP-2G-2P Strain Gauge Amplifiers
Single channel strain gauge amplifier with limit switches und for parallel operating of transducers
About the SG-IP-2G-2P Strain Gauge Amplifiers
The single-channel strain gauge measuring amplifier SG-IP-2G-2P allows supply and signal evaluation of two parallel connected strain gauge transducers with standardized sensitivity. The connection is done in 4-wire technology. For further evaluation standard analogue outputs are available. A test signal and 2 threshold value set-points as well as potential-free switching contacts (max. 30 VDC/0.5 A) for limit value monitoring are available for further evaluation. The measuring amplifier is built-in into a robust EMC die-cast aluminium enclosure (IP65) which is suited for applications in rough and industrial environments.
The amplification/channel of the amplifier can be adapted by an internal precision resistance.
The potentiometers Z (Zero) and G (Gain), which are accessible after removing the enclosure cover, allow a calibration correction.
Key features SG-IP-2G-2P
- Supply voltage 22 - 26 VDC
- Test signal 5 - 10 V, 2 adjustable threshold value set-points and switching contacts (max. 30 VDC / 0.5 A)
- EMC aluminium die-cast enclosure (IP65)
- Dimensions (W x H x D) 175 x 80 x 57 mm
Do you need this sensor for your next project?
Request a quotation today or leave your details to recieve more information from one of our experts.
Product downloads
Have it your way
Not exactly what you’re looking for? We offer standard sensors but can also help you with a tailor-made sensor or a complete measuring solution. Please contact us for advice or budgetary pricing.
Talk to an expertTechnical Specifications
Specification | Value |
---|---|
Dimension (w x h x d) | 175 x 80 x 57 mm |
Electrical connection | EMC cable gland on internal terminal block |
Enclosure | EMC aluminium die-cast enclosure (IP65) |
Input resistance | >3 MΩ |
Max. input sensitivity | 100 mV/V at 10 VDC excitation supply |
Non-linearity | ±0.05 % FSO |
Number of measuring channels | 1 (full bridge resistance >300 Ω) |
Number of relay switching contacts | 2 (max. 30 VDC / 0.5 A) |
Power consumption | 4 W max. |
Strain gauge excitation supply | +5 VDC, +10 VDC |
Supply voltage | 22 - 26 VDC |
Temperature, operating | -20 to +50 °C |
Temperature, storage | -20 to +60 °C |
Test signal | 5 - 10 V |
Weight | 750 g |