GLET-SI Interface for Data Loggers
Active modular enclosure with current output
About the GLET-SI Module
Active modular enclosure for active transducer/sensor with current signal
Fig.: Model GLET-SI2K-BNC/B514-BI5, 2 Channels, BNC
Active modular enclosures for wiring of one or two active transducers / sensors with current signal in 2or 3-wire technology in connection with a datalogger.
1-Channel Models:
- GLET-SI-BA2/B514-BI5 for data loggers of series GL2xx, GL8xx
- (Graphtec Midi Logger GL240)
- (Graphtec Midi Logger GL840-M & GL840-WV)
- GLET-SI-BNC/B514-BI5 for data loggers of series GL9xx, GL2000
2-Channel Models:
- GLET-SI2K-BA2/B514-BI5 for data loggers of series GL2xx, GL8xx
- (Graphtec Midi Logger GL240)
- (Graphtec Midi Logger GL840-M & GL840-WV)
- GLET-SI2K-BNC/B514-BI5 for data loggers of series GL9xx, GL2000
Accessories for Models with BNC
- KA-BNC-iso-sw-0.5m
- BNC safety connection cable with 2 straight BNC connectors
- material: PVC
- rating: 1000 V, CAT II (600 V CAT III)
- cable length: 0.5 m
- color: black
Do you need this sensor for your next project?
Request a quotation today or leave your details to recieve more information from one of our experts.
Product downloads
Have it your way
Not exactly what you’re looking for? We offer standard sensors but can also help you with a tailor-made sensor or a complete measuring solution. Please contact us for advice or budgetary pricing.
Talk to an expertTechnical Specifications
Specification | Value |
---|---|
Analog output signal | 0(1) ... 5 V |
Connector for transducer | 5-pin connector (Binder, supplied with mating connector) |
Dimension without connections (wxhxd) | approx. 45 x 115 x 90 mm |
Electrical connection analog output to datalogger | GLET-SI(2K)-BA2/B514-BI5: 2 mm jack, GLET-SI(2K)-BNC/B514-BI5: BNC |
Enclosure | desktop |
Environmental sealing | IP20 |
High-precision resistance | 250 Ohm |
Input signal | 0(4) ... 20 mA 2or 3-wire |
Operating temperature range | 0 ... +50 °C |
Supply voltage | 24 VDC ±5 % * |
Transducer excitation | 18 VDC (max. 30 mA) |
Related products
Need something else?
Graphtec GL240 Compact Data Logger
- Measuring Ranges: Voltage, Temperature, Humidity
- Measuring Channels: up to 10
- Resolution: 16 bit
GRAPHTEC GL840-M Multichannel Data Logger
- Measuring Ranges: Voltage, Temperature, Humidity, GL100 Sensors
- Measuring Channels: up to 200
- Resolution: 16 bit
GRAPHTEC GL840-WV Multichannel Data Logger
- Measuring Ranges: Voltage, Temperature, Humidity, GL100 Sensors
- Measuring Channels: up to 200
- Resolution: 16 bit