1. Althensensors
  2. Instrumentation
  3. Amplifiers & indicators
  4. Strain gauge amplifiers
  5. SG-INL Strain Gauge Amplifiers

SG-INL Strain Gauge Amplifiers

Single Channel Inline Strain Gauge Amplifier


About the SG-INL Strain Gauge Amplifiers

The single-channel inline strain gauge measuring amplifier SG-INL allows supply and signal evaluation of a transducer with a strain gauge full bridge greater than 300 ohms. The connection is done in 4-wire technology. For further evaluation standard analogue outputs are available. The measuring amplifier is built-in into a robust aluminium enclosure (IP20) which is suited for applications in rough and industrial environments.
The amplification can be adapted by an internal precision resistance.


The potentiometers Z (Zero) and G (Gain) accessible after removing the enclosure cover, allow a correction of the calibration. By means of an internal dip switch a change of the potentiometer Z (zero) range can be achieved.

 

Key features SG-INL

  • Supply voltage 10 - 18 VDC / 18 - 30 VDC
  • Analogue output 0 - 10 V / ±10 V
  • Aluminium enclosure (IP20)
  • Dimensions (W x H x D) 92 x 38 x 31 mm

Do you need this sensor for your next project?

Request a quotation today or leave your details to recieve more information from one of our experts.

Talk to an expert

Have it your way

Not exactly what you’re looking for? We offer standard sensors but can also help you with a tailor-made sensor or a complete measuring solution. Please contact us for advice or budgetary pricing.

Talk to an expert

Technical Specifications

Specification Value
Analogue output 0 - 10 V, ±10 V, max. 1 mA (short-period short-circuit proof)
Dimensions (w x h x d) 92 x 38 x 31 mm
Electrical connection 3 m connecting cable Type LiYCY (TP) 2 x 2 x 0.25 mm² 5 pin bead male connector Binder Series 712/423 / Series 712/423 depending on the cable diameter of the connected strain gauge sensor
Enclosure EMC aluminium die-cast enclosure (IP65)
Input resistance >3 MΩ
Isolating proof voltage input to output 200 V, higher isolated proof voltage on request
Limit frequency (-3 db) 1 kHz
Max. input sensitivity 25 mV/V at 10 VDC excitation supply
Non-linearity ±0.05 % FSO
Number of measuring channels 1 (full bridge resistance >300 Ω)
Power consumption 3 W max.
Strain gauge excitation supply 2.5 VDC, 5 VDC or 10 VDC
Supply voltage 10 to 18 VDC,18 to 30 VDC, electronics protected against voltage reversal
Temperature, operating 0 to +50 °C
Temperature, storage -20 to +60 °C
Weight 150 g