+31 (0)70 392 44 21

Visit our location page for your nearest Althen location.

sales@althen.nl

Visit our location page for your nearest Althen location.

SC-2440 Eddy Current Sensor

Self contained analog output displacement sensors

Key Features SC-2440

  • Self-contained electronics
  • Built-in temperature sensor
  • Fixed gain output
  • No calibration required
  • Low cost
  • Compact and rugged, IP-67
  • Extremely low hysteresis

Information & Quotation

Do you need budgetary pricing or have questions about this product? Let us know how we can help you!

About the SC-2440 Eddy Current Sensor

The SC-2440 system operates on a traditional Colpitts oscillator circuit where the sensor acts as the resonating coil for the oscillator. The proximity of the target to the sensor face pulls the oscillator, changing its frequency and amplitude of modulation, and controlling a variable gain oscillator section within the elec - tronic circuit. The signal is half-wave rectified and filtered to obtain an analog voltage proportional to the target position or displacement. The input power is diode protected and regulated to provide a clean low-noise signal. The output is short-circuit current protected.

Ideal for: High-precision automated assembly, OEM applications with on-board computing power, High repeatability requirements

Other features SC-2440

  • Reverse polarity and short circuit protection
  • Excellent performance with ferrous targets
  • Variable voltage input from 15 to 30 volts DC
  • Specifications
  • Datasheets
Specifications
Range
Steel target 4.0 mm (0.16 in.) with 1.0 mm offset, Aluminum target 2.5 mm (0.10 in.) with no offset
Resolution
0.001 mm (0.00004 in.) at full range
Output
0 to 10 Vdc*
Thermal Stability
0.02% FS w/ext TC
Repeatability
0.01% FS
Response Time
0.10 ms
Environmental
IP-67
Integral cable jacket
PVC
Body
Nickel-plated steel
Maximum jam nut torque
14 in-lbs (1.6 N-m)
Temperature
Operating range 0° to 70°C (32° to 158°F), Storage range 0° to 70°C (32° to 158°F), Compensation range 15° to 55°C (59° to 131°F)
Temperature Output
Temperature output voltage 0.50 to 1.20 VDC, 0 to 70° C, Sensitivity 10mV/°C, Convert V temperature out to °C Sensor °C = (Vtemp – 0.50) x 100
Analog Output
Continuous load current <50 mA, Short circuit and overload protection Yes, Warm-up time <1 minute
Input
Supply voltage required 15 to 30 Vdc, Current limit (no load current input) <50 mA, Reverse polarity protection Yes, Short circuit protection Yes
Datasheets
Downloads

Information & Quotation

Do you need budgetary pricing or have questions about this product? Let us know how we can help you!