1. Althensensors
  2. Sensors
  3. Linear position sensors
  4. LVDT sensors
  5. HC485 Series LVDT Position Sensor

HC485 Series LVDT Position Sensor

Eliminates the need for expensive and error-prone analog to digital conversion by internally converting the analog LVDT signals


Key features

  • Heavy duty digital model
  • Up To 32 Sensors On One 2-Wire Network
  • Interchangeability Without Calibration
  • Factory Calibrated Inch or Millimeter
  • User Selectable Output
  • Velocity Output Inches/mm per sec.

About the HC485 (RS-485) Digisense series Multi-drop Displacement Sensor

The HC485 sensor is available in seven bipolar measurement ranges, with standard strokes from ±.050 inches to ± 3.0 inches. Operating on a single ended 8.5 to 30.0 volt dc. input and a two-wire addressable RS-485 output, the HC 485 is ideally suited to factory automation applications.

Direct digital output eliminates the need for expensive and error prone analog to digital conversion. The analog sensor output is scaled into calibrated engineering units, by the internal microprocessor, using factory computed conversion tables, thus providing a traceable measurement without need of an on-site calibration. A certificate of calibration is shipped with every sensor.

Internal MIN, MAX and TIR functions store peak and valley readings at a maximum up-date rate of 600 samples per second to deliver the information to the host, on demand. An internal tare or zero function allows unipolar or bipolar output, as the application dictates. The HC 485 digital output LVDT is packaged in a rugged hermetically sealed stainless steel tube, suitable for use in the most demanding factory floor environments. A six-pin MS style bayonet connector is welded to the lead side of the LVDT, for ease of termination. Mating connectors are supplied upon request.

Other features HC485 (RS-485) 

  • Built-in Tare & Un-Tare
  • Built-in Min / Max Function

Applications for HC485

  • Process Control
  • Valve Position Feedback
  • Roller Gap
  • Automated Test Systems

Options

  • Captive Core
  • Metric Core
  • Guided Core
  • EAC alibration Provides 150% Stroke and 0.05% Linearity
  • Special OEM Protocols
  • Mating Connector

Do you need this sensor for your next project?

Request a quotation today or leave your details to recieve more information from one of our experts.

Talk to an expert

Have it your way

Not exactly what you’re looking for? We offer standard sensors but can also help you with a tailor-made sensor or a complete measuring solution. Please contact us for advice or budgetary pricing.

Talk to an expert

Technical Specifications

Specification Value
(rs-485) ModBus ASC II, Omega I-Series
Housing construction TIG welded 400, series stainless steel
Input current 50 mA nominal
Measurement range 3.17 to 114.3mm
Native protocols ModBus RTU
Non-linearity ±0.25% or ±0.1% FR
Output RS485
Output (units) Metric & Inches
Resolution 15-bit (minimum)
Shock survival 250 g for 11 mS
Stability 0.1% full range
Storage temp. -65ºF. to 200ºF -55ºC to 95ºC
T/c of scale factor 0.025% / °F max, (0.05% / °C max)
Termination 6-pin MS style, hermetic connector
Vibration tolerance 10g up to2 kHz

Related products

Need something else?

HCA Series LVDT Position Sensor

  • Heavy duty AC-operated model
  • All-welded stainless steel construction
  • Glass sealed, MS type connector (MIL-C-5015)
Datasheet View product

HCA-RA LVDT Position Sensor

  • Right angle (HCA-RA) version available
  • Suitable for Hostile Environments
  • Connector Termination
Datasheet View product

HCA-T-Series LVDT Position Sensor

  • 392°F [200°C] continuous operation
  • Shock and vibration tolerant
  • ±0.25% of Full Range linearity (100% of stroke)