1. Althensensors
  2. Sensors
  3. Vibration sensors
  4. General purpose vibration sensors
  5. 787-500-IS General Purpose Vibration Sensor

787-500-IS General Purpose Vibration Sensor

Low-frequency, intrinsically safe accelerometer


Key features

  • Hazardous area certified - intrinsically safe
  • High sensitivity
  • Extended low frequency response
  • Manufactured in ISO 9001 facility

About the 787-500-IS General Purpose Vibration Sensor

Intrinsically Safe, low frequency, accelerometer, high sensitivity 500 mV/g, ±5% sensitivity tolerance, low profile with side exit MIL-C-5015-style connector, case isolated, certified for use in Class I Division 1 and Zone 0 / Zone 1 hazardous areas

 

Key features 787-500-IS

  • Hazardous area certified - intrinsically safe
  • High sensitivity
  • Extended low frequency response
  • Manufactured in ISO 9001 facility

Do you need this sensor for your next project?

Request a quotation today or leave your details to recieve more information from one of our experts.

Talk to an expert

Have it your way

Not exactly what you’re looking for? We offer standard sensors but can also help you with a tailor-made sensor or a complete measuring solution. Please contact us for advice or budgetary pricing.

Talk to an expert

Technical Specifications

Specification Value
Acceleration range, vdc > 22 v 10 g peak
Amplitude nonlinearity 1%
Base strain sensitivity, max 0.0002 g/μstrain
Bias output voltage 12 VDC
Electrical noise, equiv. g1 : broadband   2.5 hz to 25 khz spectral 10 hz   100 hz   1,000 hz 250 µg 2.5 µg/√Hz 1.5 µg/√Hz 1.5 µg/√Hz
Electromagnetic sensitivity, equiv. g, max 70 µg/gauss
Frequency response1 : ±10% ±3 db 0.5 - 5,000 Hz / 0.2 - 10,000 Hz
Grounding case isolated, internally shielded
Output impedance, max 100 Ω
Power requirement: voltage source current regulating diode 18 - 28 VDC / 2 - 10 mA
Resonance frequency 22 kHz
Sealing hermetic
Sensing element design PZT, shear
Sensitivity, ±5%, 25°c 500 mV/g
Shock limit 5,000 g peak
Temperature range –50° to +120°C
Temperature response: –20°c +120°c –10% +10%
Transverse sensitivity, max 5% of axial
Vibration limit 500 g peak