1. Althensensors
  2. Sensors
  3. Weighing sensors and load cells
  4. Bending shear beam load cells
  5. DTX Double Shear Beam Load Cell

DTX Double Shear Beam Load Cell

Nickel plated alloy steel construction

Do you need this sensor for your next project?

Request a quotation today or leave your details to recieve more information from one of our experts.

Talk to an expert

Have it your way

Not exactly what you’re looking for? We offer standard sensors but can also help you with a tailor-made sensor or a complete measuring solution. Please contact us for advice or budgetary pricing.

Talk to an expert

Technical Specifications

Specification Value
Nickel plated alloy steel
Combined error ≤±0.023%
Compensated temperature range -10 °C / +40 °C
Creep at nominal load in 30 minutes 0.016%
Deflection at nominal load 0.6 mm
Input resistance 700 Ω ±7
Insulation resistance ≥5000 MΩ
Max supply voltage without damage 18 V
Minimum verification interval (v min) E max / 10000 - E max / 15000
Nominal load (e max) 9000, 13600, 18000, 23000, 27000kg
Oiml r60 accuracy class • verification intervals C3 • 3000
Operating temperature range -35 °C / +65 °C
Output resistance 700 Ω ±7
Protection class IP68
Rated output 3.0 mV/V ±0.1%
Safe overload (% of full scale) 150%
Temperature effect on span 0.002% °C
Temperature effect on zero 0.002% °C
Ultimate overload (% of full scale) 300%
Zero balance ≤±1%