FCK Bending Beam Loadcell (ATEX)

Combined error < +/- 0.02%

Features FCK

  • Range: 5 to 10kg
  • Stainless steel construction
  • Combined error < +/- 0.02%
  • Protection rating IP68

Specifications

Material
17-4 PH stainless steel
Nominal load (E max)
5 - 10 kg
Combined error
≤±0.02%
Protection class
IP68
Rated output
2 mV/V ±1%
Temperature effect on zero
0.002% °C
Temperature effect on span
0.002% °C
Compensated temperature range
-10 °C / +40 °C
Operating temperature range
-30 °C / +65 °C
Creep at nominal load in 30 minutes
0.02%
Max supply voltage without damage
15 V
Input resistance
400 Ω ±20
Output resistance
352 Ω ±3
Zero balance
±2%
Insulation resistance
>5000 MΩ
Safe overload (% of full scale)
150%
Ultimate overload (% of full scale)
200%
Deflection at nominal load
0.4 mm
  • Follow us: