SX36RV120 RVDT
Provides a sinusoidal signal, with a linear voltage over the measurement range
About the SX36RV120 RVDT
The SX36RV120 provides a sinusoidal signal, with a linear voltage over the measurement range.
The primary is excited by an AC voltage, and is picked up by the secondary winding on the transformer principle; the position of the rotating core determines the transformer ratio of each secondary winding.
As the secondaries are wound in opposition, the difference between the secondary outputs is proportional to the core angle, relative to the housing.
The zero position is where each secondary voltage is equal and opposite. This is determinated in factory, and the position marked on both spindle and housing.
The sensor is made from a light anodised alloy. Output is given through a 20 meter ETFE isolated cable with gauge 26 copper wires.
Applications for SX36RV120
- Valve position measurement
- Steam turbine servo-valve control
- In surface industries
Behöver du den här sensorn till ditt nästa projekt?
Begär en offert eller lämna dina uppgifter för att få mer information från en av våra experter.
Få det på ditt sätt
Inte exakt vad du letar efter? Vi erbjuder standardsensorer, men kan också hjälpa dig med en komplett skräddarsydd lösning. Kontakta oss för rådgivning eller budgetprissättning.
Prata med en expertRelaterade produkter
Behöver du något annat?
R30D RVDT
- Angular ranges: ±30º (standard), ±40º, ±60º
- Temp. coefficient of sensitivity: 0.07%/ºC
- High level, low noise DC output
R30A RVDT
- Angular range: ±30º to ±60º
- High reliability and performance
- -55°C to +150°C operating temperature
R36AS RVDT
- Angular range: ±30° to ±60°
- Rugged stainless steel housing
- High accuracy & infinite resolution