APR3800 Protran® Standard Pressure Transducer
Flush Diaphragm Pressure Transmitter
Nyckelfunktioner
- Easy clean flush membrane to prevent clogging
- Thick film sensor technology for long service life
- Pressure ranges to 40 bar
- Range of sanitary grade pressure fittings
- ATEX/IECEx option available (includes M1 for mining applications)
About the APR3800 Pressure Transmitter
The APR3800 series offer a range pressure transmitters with integrated or remote barrier seals for applications where direct media contact must be prevented. Robustly constructed from stainless steel, this range of pressure trans-mitters incorporates the latest strain gauge technology together with a custom IC amplifier offering excellent stability and accuracy over a long service life. The range offers a stable and accurate output signal of 4-20 mA with options for 0-5 V and 0-10 V.
Typical applications include food processing, pharmaceutical, petrochemi-cal, waste water and slurry handling. In these installations the process media may corrode the sensing diaphragm or clog the narrow pressure inlet on a standard transmitter. The flush membrane can be easily cleaned for long term reliability and outstanding performance. For hygienic applications the APR3800 series provides a sanitary grade pressure fitting. Seals are available in a variety of forms and materials for a wide range of applications and can be directly attached to the proposed connection or remotely via stainless steel capillary. Pressure ranges available from 0-200 mbar to 0-40 bar.
An optional ATEX and IECEx approved versions of this range are available for explosion protection for flammable gases (zone 0), dusts (zone 20) and mining areas (group I M1).
Key Features
- Easy clean flush membrane to prevent clogging
- Thick film sensor technology for long service life
- Pressure ranges to 40 bar
- Range of sanitary grade pressure fittings
- ATEX/IECEx option available (includes M1 for mining applications)
Behöver du den här sensorn till ditt nästa projekt?
Begär en offert eller lämna dina uppgifter för att få mer information från en av våra experter.
Produktnedladdningar
Få det på ditt sätt
Inte exakt vad du letar efter? Vi erbjuder standardsensorer, men kan också hjälpa dig med en komplett skräddarsydd lösning. Kontakta oss för rådgivning eller budgetprissättning.
Prata med en expertTekniska specifikationer
Specifikation | Värde |
---|---|
Accuracy nlhr | ≤ ±0.3 % of span BFSL |
Atex/icex approval option (4-20ma version only) | Ex II 1 G Ex ia IIC T4 Ga (zone 0) Ex II 1 D Ex ia IIIC T135 °C Da (zone 20) Ex I M 1 Ex ia I Ma (group 1 M1) |
Insulation resistance | > 100 MΩ @ 50 VDC |
Operating media temperature | -20 °C to +85 °C (-4 °F to +185 °F) |
Output signal | 4 - 20 mA (2 wire) |
Overpressure safety: | 1.5x for all ranges |
Pressure reference | Gauge |
Protection of supply voltage | Protected against supply voltage reversal up to 50 V |
Sensor technology | Ceramic Thick Film or Isolated Piezoresistive Silicon |
Standard pressure ranges (bar) | 0-1 bar Vac; 0-200mbar, 0-1 bar; 0-2.5 bar; 0-6 bar; 0-10 bar; 0-16 bar; 0-25 bar; 0-40 bar (other options available)ar, 0-900 mbar (other ranges available) |
Supply voltage | 13 - 36 VDC |