Nyckelfunktioner

  • High operating temperatures of up to 250ºC
  • Easy clean flush membrane to prevent clogging
  • Thick film sensor technology for long service life
  • Pressure ranges to 400 bar
  • Good chemical compatibility for various applications
  • ATEX/IECEx option available
  • Integral O-ring seal option to ensure flush pressure seal

About the APR3860 | APR3861 | APR3862 High Temperature Pressure Transducer

The APR3860 high temperature pressure transmitter has been designed to meet the requirements of the majority of industrial pressure measurement applications where a hygienic flush diaphragm connection is required. Robustly constructed from stainless steel, the APR3860 pressure transmitter permits accurate pressure measurement at elevated temperatures. Output options include 0-5 Vdc, 0-10 Vdc and 4-20 mA. This transmitter is suitable for use at media temperature up to 250 ºC. Typical applications include food processing, pharmaceutical and petrochemical. The flush membrane can be easily cleaned for long term reliability and outstanding performance. The APR3860 offers a stable and accurate output signal of 4-20 mA with options for 0-5 Vdc, 0-10 Vdc and other output signals. Electrical connection is via a detachable DIN connector allowing easy access to zero and span adjustment. Pressure ranges available from 0-10 bar to 0-400 bar.


Optional weldable boss is available to ensure flush-face installation of transmitter to tanks and pipe-work.


An optional ATEX and IECEx approved version of this product is available for explosion protection for flammable gases (zone 0), dusts (zone 20) and mining areas (group I M1).

Behöver du den här sensorn till ditt nästa projekt?

Begär en offert eller lämna dina uppgifter för att få mer information från en av våra experter.

Prata med en expert

Få det på ditt sätt

Inte exakt vad du letar efter? Vi erbjuder standardsensorer, men kan också hjälpa dig med en komplett skräddarsydd lösning. Kontakta oss för rådgivning eller budgetprissättning.

Prata med en expert

Tekniska specifikationer

Specifikation Värde
Accuracy nlhr ≤ ±0.3 % of span BFSL
Atex/iecex approval option (4-20ma version only) PR3860 - Ex II 1 G Ex ia IIC T4 Ga (zone 0) Ex II 1 D Ex ia IIIC T135 °C Da (zone 20) Ex I M 1 Ex ia I Ma (group 1 M1)
Atex/iecex safety values PR3860 - Ui = 28 V Ii = 119 mA Pi = 0.65 W Li = 0.1 µH Ci = 62 nF Temperature Range = -20 °C to +70 °C Max. cable length = 105 m
Electrical connection Mating socket EN175301-803 Form A (ex DIN43650) rated IP65 with PG9 cable entry (other options available)
Insulation resistance > 100 MΩ @ 50 VD
Load driving capability 4 – 20 mA: RL < [UB - 13 V] / 20 mA (e.g. with supply voltage (UB) of 36V, max. load (RL) is 1150 Ω); 0 – 5 V: max load RL > 5 KΩ; 0 – 10 V: max load RL > 10 KΩ
Operating ambient temperature -20 °C to +85 °C (-4 °F to +185 °F)
Operating media temperature 0 °C to +205 °C (+32 °F to 185°F) with standard o-ring ; 0 °C to +250 °C (+32 °F to +482 °F) with optional o-ring (sensor and electronics thermally insulated from media temperature
Output signal 4 – 20 mA (2 wire), 0 – 5 V (4 wire), 0 – 10 V (4 wire)
Pressure reference Gauge
Protection of supply voltage Protected against supply voltage reversal up to 50 V
Sensor technology Ceramic Thick Film
Standard pressure ranges (bar) 0 – 10 bar; 0 – 25 bar; 0 – 60 bar; 0 – 100 bar; 0 – 250 bar; 0 – 400 bar (other options available)
Standard pressure ranges (psi) 0-150 psi; 0-300 psi; 0-1,500 psi; 0-3,000 psi; 0-6,000 psi (other options available)
Storage temperature +5 °C to +40 °C (+41 °F to +104°F) Recommended Best Practice
Supply voltage 13 – 36 VDC, 13 – 30 VDC, 13 – 30 VDC
Zero offset and span tolerance ±1.0 %FS at room temperature; ±5 %FS (approx.) adjustment with easy access trimming potentiometers on amplified versions only