1. Althensensors
  2. Capteurs
  3. Capteurs de pression
  4. Capteurs de pression standard
  5. MPM280Au Pressure Sensor

MPM280Au Pressure Sensor

Measuring element, specially developed for hydrogen measurement applications


Caractéristiques principales

  • Pressure range: -1bar...0bar ~ 0.35bar...200bar
  • Gauge / sealed gauge / absolute
  • Isolated structure, Suitable for hydrogen pressure measurement
  • Φ19mm OEM pressure element
  • Corrugated diaphragm with gold plat

About the MPM280Au Pressure Sensor

MPM280Au pressure sensing element is a measuring element specially developed for hydrogen measurement applications. The sensor is flat membrane structure and adopts gold plating techniques on the membrane to effectively prevent “hydrogen embrittlement" and "hydrogen penetration". It improves the working life of the sensor as well as ensure the site safety. MPM280Au pressure sensor selects the high-precision and high-stability diffusion silicon piezoresistive pressure sensitive chip produced by famous international manufacturer. The pressure
sensitive component is automatically tested by computer
and fabricated with zero point correction and temperature
compensation. With high accuracy and good stability, it can
be widely used in various hydrogen pressure measurement applications.

Applications

  • Hydrogen pressure measurement instrument
  • Hydrogen production and purification equipment
  • Hydrogen storage and transportation equipmen

Electrical Performance

  • Power supply: ≤ 2.0mA DC
  • Electrical connection: Ф0.5mm gold-plated Kovar pin or 100mm flexible silicone rubber wires
  • Common mode voltage output: 50% of the input (typ.)
  • Input impedance: 3kΩ ~ 8kΩ
  • Output impedance: 3.5kΩ ~ 6kΩ
  • Response time (10% ~ 90%): <1ms
  • Insulation resistor: 100MΩ@100V DC
  • Overload: 2 times FS

Construction Performance

  • Diaphragm: Stainless steel 316L with gold plated
  • Housing: Stainless steel 316L
  • Vented tube: Stainless steel 316L
  • Pin: Gold-plated Kovar
  • Net weight: ~ 16g

Environment Condition

  • Shock: No change at 10gRMS,(20~2000)Hz
  • Impact: 100g, 11ms
  • Media compatibility: High purity hydrogen or mixed gas with high hydrogen content

Avez-vous besoin de ce capteur pour votre prochain projet?

Demandez un devis dès aujourd'hui ou laissez vos coordonnées pour recevoir plus d'informations de la part de l'un de nos experts.

Parler à un expert

Téléchargements de produits

Faites-le à votre façon

Vous ne trouvez pas exactement ce que vous cherchez ? Nous proposons des capteurs et des systèmes de mesure standard, mais nous pouvons également vous aider à concevoir un capteur sur mesure ou une solution de mesure complète. N'hésitez pas à nous contacter pour obtenir des conseils ou un devis.

Parler à un expert

Spécifications techniques

Spécifications Valeur
Fs output (mv dc) 60
Hysteresis (%fs) ±0.05 ... ±0.075
Linearity (%fs,bfsl) ±0.15...±0.25
Repeatability (%fs) ±0.05...±0.075
Zero output (mv dc) ±1.0 ... ±2.0
Zero thermal error (%fs, @35℃) ±0.75 ... ±1.0