About the TLB Digital Amplifier
Weight amplifier and indicator for Omega/DIN rail mounting suitable for back panel; space-saving vertical shape.
Key features TLB
- Six-digit semialphanumeric display (height 8 mm), 7 segment LED
 - Four buttons
 - Dimensions: 25 x 115 x 120 mm
 
The instrument is equipped with a RS485 serial port and an analog output:
- RS485 for connection to:
- - PC/PLC up to 32 instruments (max 99 with line repeaters) by ASCII Laumas protocol (compatible with W60000) or ModBus RTU Protocol
 - - Remote display
 
 - Optoisolated analog output 16 bit: 0 ... 20 mA; 4 ... 20 mA (max 300 Ohm); 0 ... 10 V; 0 ... 5 V; ±10 V; ±5 V (min 10 kOhm).
 
Theoretical calibration by using buttons.
Do you need this sensor for your next project?
Request a no-obligation quote or send us your contact details for a free, no-obligation consultation. Our sales engineers will then contact you within a maximum of 1 to 2 working days.
Product downloads
Talk to our experts
Not exactly what you are looking for? We offer standard sensors, but can also help you with sensors adapted for you or a fully customised measurement solution. Contact us for advice or pricing.
Talk to an expertTechnical Specifications
| Specification | Value | 
|---|---|
| A/d converter | 24 bit (16000000 points) 4.8 kHz | 
| Digital filter / conversion rate | 0.012 - 7 s / 5 - 300 Hz | 
| Divisions, max | ±999999 | 
| Linearity | <0.01% FS | 
| Linearity of analog output | <0.01% FS | 
| Load cell sensitivity, max. | ±7 mV/V | 
| Logic inputs | 2x - optoisolated 5 - 24 VDC PNP | 
| Logic relay outputs | 3x - max. 115 VAC / 150 mA | 
| Number of load cells (parallel and supply) | max. 8 (350 Ω); 5 VDC / 120 mA | 
| Power supply and consumption: | 12 - 24 VDC ±10 %; 5 W | 
| Rs485 port - baud rate | 2400, 4800, 9600, 19200, 38400, 115200 |