1. Althensensors
  2. Sensors
  3. Pressure sensors
  4. Differential pressure sensors
  5. APR3200 Differential Pressure Transducer

APR3200 Differential Pressure Transducer

High stability and performance, suitable for use with all liquids and gases compatible with stainless steel and titanium


Key features

  • Wide range of pressure ranges to 200 bar DP
  • WET/WET or DRY/DRY operation
  • Available for gauge reference or bi-directional measurement
  • Durable designs for industrial and commercial installations
  • R.F.I. Shielded, against electromagnetic radiation
  • ATEX/IECEx option available (Including M1)

About the APR3200 Differential Pressure Transducer

The APR3200 differential pressure transmitter uses two titanium alloy pressure sensors, offering high stability and performance with true wet/wet operation, suitable for use with all liquids and gases compatible with stainless steel and titanium.

The unique Silicon-on-Sapphire sensor technology provides outstanding performance and gives excellent stability over a wide temperature range. The sensor can endure higher over- pressures and provides superb corrosion resistance, with virtually no hysteresis. The outstanding insulation properties allow the sensor to operate over a very wide temperature range without loss of performance.

Applications include flow measurement with orifice plates and mass flow meters, plus static differential pressure measurement and control in combustion chambers, also condition monitoring and filter monitoring in high pressure hydraulic systems or any application on liquid or gas requiring reliable differential pressure measurement. Electrical connector is DIN plug and socket. Access to zero and span adjustment is by removing top plate for easy on-site adjustment. Pressure connection as standard is via two 1/4" BSP female connections. A mounting plate is available for bulkhead mounting. Ranges available from 0-500 mbarDP to 0-200 barDP

An optional ATEX and IECEx approved version of this product is available for explosion protection for flammable gases (zone 0), dusts (zone 20) and mining areas (group I M1).

Do you need this sensor for your next project?

Request a quotation today or leave your details to recieve more information from one of our experts.

Talk to an expert

Have it your way

Not exactly what you’re looking for? We offer standard sensors but can also help you with a tailor-made sensor or a complete measuring solution. Please contact us for advice or budgetary pricing.

Talk to an expert

Technical Specifications

Specification Value
Accuracy nlhr: ≤ ±0.3 % of span BFSL (Optional higher accuracy version of s ±0.1 % of span BFSL available)
Output signal 4-20 mA (2 wire) | 0-5 V (4 or 3 wire) | 0-10 V ( 4 or 3 wire)
Pressure reference Differential
Protection of supply voltage: Protected against supply voltage reversal up to 50 V
Sensor technology Silicon-on-Sapphire (SoS)
Standard pressure range: 0-7.5 psi; 0-15 psi; 0-150 psi; 0-750 psi; 0-1,500 psi; 0-3,000 psi (other ranges available)
Storage temperature: +5 °C to +40 °C (+41 °F to +104°F) Recommended Best Practice
Supply voltage 10-36 VDC | 10-36 VDC | 13-30 VDC