1. Althen Sensors
  2. Sensors
  3. Strain sensors & strain gauges
  4. Weldable strain gauges for static and dynamic strain measurement
  5. AWMD-8 Full Bridge Strain Gauges for Dynamic Measurement

AWMD-8 Full Bridge Strain Gauges for Dynamic Measurement

8mm full bridge gauge, is applicable up to 800°C and dedicated to dynamic measurement


Key features

  • 1% (10000×10⁻⁶ strain) Strain limit
  • Operational temperature: -196~+800°C
  • Inconel backing, Special alloy element
  • Type: Full bridge, for dynamic measurement
  • Gauge resistance: 120Ω
  • Gauge length: 8mm

About the AWMD-8 Full Bridge for Dynamic Measurement

The AWMD is applicable up to 800°C and is dedicated to dynamic strain measurement. A high pass filter is a standard accessory. Using the high pass filter, unnecessary direct current component and low frequency component (thermal output, drift, etc.) are cancelled. A DC exciting dynamic strain meter such as DC-96A/DC-97A, smart strain recorder such as DC-204R, or multi-recorder TMR-200 series should be used for the measurement.

AW series high temperature weldable strain gauge
These strain gauges have strain sensing elements fully encapsulated in corrosion-resisting metal tubes made of stainless steel or Inconel (except AW-6-350). The strain gauge backings are also made of the same material, and the gauges are installed by spot welding to metal specimens using a dedicated spot welder. The maximum operating temperatue is 800°C for the AWHU. These gauges are suited to measurement in high temperature harsh environments such as underwater or gas-filled atmosphere, or for long term. The AWC-2B and AWCH-2 are available in 1-Gauge 4-Wire configuration.

Do you need this sensor for your next project?

Request a no-obligation quote or send us your contact details for a free, no-obligation consultation. Our sales engineers will then contact you within a maximum of 1 to 2 working days.

Talk to an expert

Talk to our experts

Not exactly what you are looking for? We offer standard sensors, but can also help you with sensors adapted for you or a fully customised measurement solution. Contact us for advice or pricing.

Talk to an expert

Technical Specifications

Specification Value
Backing Inconel
Bonding adhesive Spot welding (TML spot welder W-50R is required)
Element Special alloy
Fatigue life at room temperature 1×10⁶ (±1000×10⁻⁶ strain)
Main object material Metal
Operational temperature(°c) -196~+800°C
Strain limit 1% (10000×10⁻⁶ strain)
Temperature compensation range(°c) -