Key features

  • Hazardous area certified - intrinsically safe
  • High sensitivity
  • Extended low frequency response

About the 787-500-IS General Purpose Vibration Sensor

Intrinsically Safe, low frequency, accelerometer, high sensitivity 500 mV/g, ±5% sensitivity tolerance, low profile with side exit MIL-C-5015-style connector, case isolated, certified for use in Class I Division 1 and Zone 0 / Zone 1 hazardous areas

 

Key features 787-500-IS

  • Hazardous area certified - intrinsically safe
  • High sensitivity
  • Extended low frequency response

Do you need this sensor for your next project?

Request a no-obligation quote or send us your contact details for a free, no-obligation consultation. Our sales engineers will then contact you within a maximum of 1 to 2 working days.

Talk to an expert

Talk to our experts

Not exactly what you are looking for? We offer standard sensors, but can also help you with sensors adapted for you or a fully customised measurement solution. Contact us for advice or pricing.

Talk to an expert

Technical Specifications

Specification Value
Acceleration range, vdc > 22 v 10 g peak
Amplitude nonlinearity 1%
Base strain sensitivity, max 0.0002 g/μstrain
Bias output voltage 12 VDC
Electrical noise, equiv. g1 : broadband   2.5 hz to 25 khz spectral 10 hz   100 hz   1,000 hz 250 µg 2.5 µg/√Hz 1.5 µg/√Hz 1.5 µg/√Hz
Electromagnetic sensitivity, equiv. g, max 70 µg/gauss
Frequency response1 : ±10% ±3 db 0.5 - 5,000 Hz / 0.2 - 10,000 Hz
Grounding case isolated, internally shielded
Output impedance, max 100 Ω
Power requirement: voltage source current regulating diode 18 - 28 VDC / 2 - 10 mA
Resonance frequency 22 kHz
Sealing hermetic
Sensing element design PZT, shear
Sensitivity, ±5%, 25°c 500 mV/g
Shock limit 5,000 g peak
Temperature range –50° to +120°C
Temperature response: –20°c +120°c –10% +10%
Transverse sensitivity, max 5% of axial