| Specification | Value | 
|---|---|
| Material | Nickel plated alloy steel | 
| Combined error | ≤±0.023% | 
| Compensated temperature range | -10 °C / +40 °C | 
| Creep at nominal load in 30 minutes | 0.016% | 
| Deflection at nominal load | 0.6 mm | 
| Input resistance | 700 Ω ±7 | 
| Insulation resistance | ≥5000 MΩ | 
| Max supply voltage without damage | 18 V | 
| Minimum verification interval (v min) | E max / 10000 - E max / 15000 | 
| Nominal load (e max) | 9000, 13600, 18000, 23000, 27000kg | 
| Oiml r60 accuracy class • verification intervals | C3 • 3000 | 
| Operating temperature range | -35 °C / +65 °C | 
| Output resistance | 700 Ω ±7 | 
| Protection class | IP68 | 
| Rated output | 3.0 mV/V ±0.1% | 
| Safe overload (% of full scale) | 150% | 
| Temperature effect on span | 0.002% °C | 
| Temperature effect on zero | 0.002% °C | 
| Ultimate overload (% of full scale) | 300% | 
| Zero balance | ≤±1% |