ALL Single Point Load Cell (ATEX)

For platforms 250 x 350mm

View technical specifications

Key features

  • Capacity: 3, 5, 10, 15, 20, 30, 50kg
  • Aluminium alloy
  • Combined error ≤ ±0.02% (0.017% C4; 0.014% C5)
  • Protection class IP65

Do you need this sensor for your next project?

Request a no-obligation quote or send us your contact details for a free, no-obligation consultation. Our sales engineers will then contact you within a maximum of 1 to 2 working days.

Talk to an expert

Talk to our experts

Not exactly what you are looking for? We offer standard sensors, but can also help you with sensors adapted for you or a fully customised measurement solution. Contact us for advice or pricing.

Talk to an expert

Technical Specifications

Specification Value
Compensated temperature range -10 °C / +40 °C
Creep at nominal load in 30 minutes 0.015%
Deflection at nominal load 0.5 mm
Input resistance 409 Ω ±6
Insulation resistance ≥5000 MΩ
Max supply voltage without damage 18 V
Measurement range 3, 5, 10, 15, 20, 30, 50kg
Operating temperature range -35 °C / +65 °C
Output resistance 350 Ω ±3
Rated output 2 mV/V ±10%
Safe overload (% of full scale) 150%
Temperature effect on span 0.0014% °C
Temperature effect on zero 0.0017% °C
Ultimate overload (% of full scale) 300%
Zero balance ≤ ±2%