Key features

  • Load capacities: 1000 kg and 2000 kg
  • OIML R60 C3 certified
  • Aluminum alloy construction
  • IP65 protection class
  • Combined error ≤ ±0.02%
  • Optional ATEX, IECEx, ISO 376, ASTM E74 certifications

Performance ATL Single-point load cell

The ATL is a high-capacity single-point load cell developed for large industrial platforms up to 1200x1200 mm. With capacities of 1000 kg and 2000 kg and a combined error of ≤ ±0.02%, it ensures precise and repeatable measurements in demanding weighing environments.

Use conditions

Made of robust aluminum alloy and protected to IP65, ATL is suitable for dry and dusty industrial settings. It’s OIML R60 C3 certified (3000 divisions) and available with optional certifications for metrology and hazardous zones—including ATEX, IECEx, and ISO 376 for legal-for-trade and laboratory-grade use.

Typical applications

  • Large platform scales
  • Industrial weighing systems
  • Warehouse and material handling weighing
  • OEM systems requiring high-capacity single-point integration
  • ATEX zone weighing solutions

Why choose ATL?

ATL combines mechanical strength, certified accuracy, and excellent environmental resistance. With a 2 mV/V output and standard M16 mounting, it integrates easily into heavy-duty weighing platforms. Optional traceable calibration (LAT Accredia) ensures compliance in legal or scientific applications.

Do you need this sensor for your next project?

Request a no-obligation quote or send us your contact details for a free, no-obligation consultation. Our sales engineers will then contact you within a maximum of 1 to 2 working days.

Talk to an expert

Talk to our experts

Not exactly what you are looking for? We offer standard sensors, but can also help you with sensors adapted for you or a fully customised measurement solution. Contact us for advice or pricing.

Talk to an expert

Technical Specifications

Specification Value
Combined error ≤±0.02%
Compensated temperature range -10 °C / +40 °C
Creep at nominal load in 30 minutes 0.02%
Deflection at nominal load 0.8 mm
Input resistance 406 Ω ±6
Insulation resistance ≥5000 MΩ
Material Aluminum alloy
Max supply voltage without damage 18 V
Minimum verification interval (vₘᵢₙ) Eₘₐₓ / 7000
Nominal load (eₘₐₓ) 1000 - 2000 kg
Oiml r60 accuracy class • verification intervals C3 • 3000
Operating temperature range -35 °C / +65 °C
Output resistance 350 Ω ±3
Protection class IP65
Rated output 2 mV/V ±10%
Safe overload (% of full scale) 150%
Temperature effect on span 0.0014% °C
Temperature effect on zero 0.0017% °C
Ultimate overload (% of full scale) 300%
Zero balance ≤±1%