1. Althen Sensors
  2. Sensors
  3. Weighing sensors and load cells
  4. Intrinsically safe load cells
  5. FTKL Shear Beam Load Cell (ATEX)

FTKL Shear Beam Load Cell (ATEX)

Accuracy class C4/C5 (OIML R60)


Key features

  • Range: 500, 1000, 1500, 2000, 3000, 5000kg
  • Special steel construction
  • Combined error < +/- 0.02% (0.017% C4; 0.014% C5)
  • Protection rating IP67
  • Accuracy class C4/C5 (OIML R60)

Do you need this sensor for your next project?

Request a no-obligation quote or send us your contact details for a free, no-obligation consultation. Our sales engineers will then contact you within a maximum of 1 to 2 working days.

Talk to an expert

Talk to our experts

Not exactly what you are looking for? We offer standard sensors, but can also help you with sensors adapted for you or a fully customised measurement solution. Contact us for advice or pricing.

Talk to an expert

Technical Specifications

Specification Value
Combined error ≤±0.02% | ≤±0.017% | ≤±0.014%
Compensated temperature range -10 °C / +40 °C
Creep at nominal load in 30 minutes 0.02%
Deflection at nominal load 0.4 mm
Input resistance 350 Ω ±3.5
Insulation resistance ≥5000 MΩ
Material Special steel
Max supply voltage without damage 18 V
Minimum verification interval (v min) E max / 10000 | E max / 15000 | E max / 20000 | E max / 18000
Nominal load (e max) 500 - 1000 - 1500 kg, 2000 - 3000 - 5000 kg | 500 - 1000 kg, 1500 - 2000 kg | 3000 - 5000 kg
Oiml r60 accuracy class • verification intervals C3 • 3000 | C4 • 4000 | C5 • 5000
Operating temperature range -35 °C / +65 °C
Output resistance 350 Ω ±3.5
Protection class IP67
Rated output 3 mV/V ±0.1%
Safe overload (% of full scale) 150%
Temperature effect on span 0.0014% °C
Temperature effect on zero 0.0018% °C
Ultimate overload (% of full scale) 300%
Zero balance ≤±1%