Conventional Multi-hole Probes
Three,- five- and seven-hole probes
About the conventional Multi-hole Probes
Conventional Multi-Hole Probes are proficient in measuring flow speed and direction with high accuracy. These fundamental flow measurement tools can be manufactured in multiple configurations and geometries including straight, L-shaped, cobra and eccentric ferrule racetrack geometries, with conical, faceted, or hemispherical tips.
A complete flow data system is available by pairing our Multi-Hole Probe with our Micro Air Data Computer (several models available). When the probe is inserted into the flow, the pressures measured at each port are interpreted by our pressure-to-velocity reduction software to report magnitude and direction of the flow velocity vector with respect to the probe, as well as static and total pressure.
Key features conventional Multi-hole Probes
- Tip Diameters as small as 1.59 mm
- Temperature ratings up to 500 C
- Probe calibrations from 5 m/s to Mach 2.0
- 2000 calibration points
- NIST-Traceable calibrations and specialized calibrations available
- Custom engineering solutions available
- Average measured angular deviation of <1 °
- Average measured velocity deviations of 1 % or ± m/s
Applications conventional Multi-hole Probes
- Aerospace
- Automotive
- Turbo machinery
- Wind turbine
- Wind tunnel testing
Avez-vous besoin de ce capteur pour votre prochain projet?
Demandez un devis dès aujourd'hui ou laissez vos coordonnées pour recevoir plus d'informations de la part de l'un de nos experts.
Faites-le à votre façon
Vous ne trouvez pas exactement ce que vous cherchez ? Nous proposons des capteurs et des systèmes de mesure standard, mais nous pouvons également vous aider à concevoir un capteur sur mesure ou une solution de mesure complète. N'hésitez pas à nous contacter pour obtenir des conseils ou un devis.
Parler à un expertSpécifications techniques
Spécifications | Valeur |
---|---|
Angle error | ± 1° |
Calibration flow speeds | 5 m/s to Mach 2.0 |
Flow cone angle of receptivity | 30° (3HP), 50° (5HP), 70° (7HP) NOTE: This is not directly related to the conical angle of the tip |
Flow temp. limits | Standard: 0 – 500°C |
Frequency response | Standard: <50 Hz |
Material | 300 Series Stainless Steel Construction, Including Shafts and Internal Tubing |
Media | Standard: Non-Reactive Gases, Water |
Mounting | Standard: Hex Prism, Optional: Rectangular Prism, Cylindrical with Flat |
Number of holes | 3, 5, 7 |
Pneumatic connection | Exit Tubing of 1.02 mm (0.040” ) OD with Tubulation |
Probe geometry | Straight, Cobra, L-Shaped, Drilled Elbow |
Probe reference | Flat on Hex Mount |
Temperature measurement | Optional: Thermocouple |
Thermodynamic data | Reference Pressure, Total Temperature |
Tip diameter | Standard: 3.18 mm, Optional: 1.59 mm, 2.38 mm, 6.35 mm |
Tip geometry | Standard: 60° Conical |
Velocity error | <1% or 1m/s, (whichever is larger) |
Produits apparentés
Besoin d'autre chose?
Micro Air Data Systems
- Multiple models for different applications
- Reliable and expertly engineered
- Certifications for operating in harsh environments
Aeroprobe Services
- Superior calibration techniques
- Quality consultancy by credited engineers
- High reliability
Air Data Probes
- 1, 3, or 5 tip ports with a static ring
- High accuracy NIST traceable calibrations
- Up to 500 discrete aerodynamic calibration points per speed