GLET-SG2K-BNC-BI7 Interface for Data Loggers
Active modular enclosure with 2 channel strain gauge amplifier

About the GLET-SG2K Module
Active modular enclosure with 2 channel strain gauge amplifier
- Connection via BNC and jack
- Supply voltage: 24 VDC ±5 %
- Dimension: 45 x 115 x 90 mm
Active modular enclosure for the connection of passive strain gauge transducers / sensors (bridge resistance more than 350 Ohm) in connection with a datalogger.
GLET Module GLET-2G2K-BNC-BI7 can be used for the following data loggers
- GL2xx (Graphtec Midi Logger GL240)
- GL8xx (Graphtec Midi Logger GL840-M & GL840-WV)
- GL9xx (Graphtec Midi Logger GL980)
- GL2000 (Graphtech Midi Logger GL2000)
Specifications
Number of measuring channels
2 Potentiometers for zero and span adjustment
Strain gauge excitation
5 VDC (max. 15 mA/channel)
Input sensitivity
1 … 3 mV/V
Limit frequency
1 kHz
Connector for transducer
7-pin connector (Binder, supplied with mating)
Analog output signal
0 … 10 V, ±10 V
Analog output rating
max. 1 mA
Electrical connection analog output to datalogger
2 mm jack
Supply voltage
24 VDC ±5 % *)
Dimension without connectors (WxHxD)
approx. 45 x 115 x 90 mm
Environmental sealing
IP20
Operating temperature range
0 ... +50 °C