1. Althensensors
  2. Sensors
  3. Force sensors
  4. Cylindrical force sensors
  5. ALF327 Cylindrical Force Sensor

ALF327 Cylindrical Force Sensor

Canister loadcell


Key features

  • Full load range: 10kN, 20kN, 50kN, 100kN, 200kN 500kN, 1MN, 2MN
  • Load direction: compression
  • Non-lin./hysteresis:0.05/0.05% RL - 0.1/0.4% RL
  • Low contact pressure
  • Load spreading base
  • Spigot or recess location
  • Sealed to IP67

About the ALF327 Cylindrical Force Sensor

The ALF327 is a robust canister loadcell that is ideally suited to compression force measurement applications in harsh conditions. The loadcell is deliberately over engineered to achieve a low contact surface pressure under high loading.

Smaller column type loadcells, such as the ALF218, are available and we can cover the ALF327 load ranges with smaller designs. Please consult our engineering department.

All standard ranges are manufactured in stainless steel.
* Repeatability errors will increase if the loadcell is rotated to ±0.06% of RL.

Notes
1. AL = Applied load. 3. Temperature coefficients apply over the compensated range.
2. RL = Rated load. 4. The load must be applied directly through the central loading axis.

Connections
The loadcell is fitted with 2 metres of PVC insulated 4 core screened cable type 16-2-4C or a 4 pin Binder 723 series chassis plug.
Excitation + = Red or pin 1 Signal + = Yellow Screen = Orange
Excitation - = Blue or pin 2 Signal - = Green

Parameter 10 - 50kN 100 - 1000kN 2000kN Unit
Non-linearity - Terminal ±0.05 ±0.1 ±0.4 % RL
Hysteresis ±0.05 ±0.4 ±0.4 % RL
Creep - 20 minutes ±0.05 ±0.05 ±0.05 % AL
Repeatability (excluding rotational effects)* ±0.02 ±0.03 ±0.03 % RL
Rated output - Nominal 1.2 1.2 1.2 mV/V
Rated output - Rationalised 1.0 1.0 1.0 mV/V
Rationalisation tolerance ±0.5 ±0.5 ±0.5 % RL
Zero load output ±4 ±4 ±4 % RL
Temperature effect on rated output per °C ±0.005 ±0.005 ±0.005 % AL
Temperature effect on zero load output per °C ±0.01 ±0.01 ±0.01 % RL
Temperature range - Compensated -10 to +50 -10 to +50 -10 to +50 °C
Temperature range - Safe -10 to +80 -10 to +80 -10 to +80 °C
Excitation voltage - Recommended 10 10 10 V
Excitation voltage - Maximum 20 20 20 V
Bridge resistance 700 700 700 Ω
Insulation resistance - Minimum at 50Vdc 500 500 500
Overload - Safe 50 50 50 % RL
Overload - Ultimate 200 200 200 % RL
Sealing IP67 IP67 IP67  
Weight - Nominal (excluding cable) 1.6 8 to 24.1 28.3 kg

Do you need this sensor for your next project?

Request a quotation today or leave your details to recieve more information from one of our experts.

Talk to an expert

Have it your way

Not exactly what you’re looking for? We offer standard sensors but can also help you with a tailor-made sensor or a complete measuring solution. Please contact us for advice or budgetary pricing.

Talk to an expert