LSO Single-Axis Analog Inclinometer
Precise fluid damped, flexure suspension servo inclinometer
Key features
- Extremely high resolution and low hysteresis of less than 0.0005% of full range output.
- Extremely robust designed to withstand shocks in excess of 1500g and vibration of 20 grms.
- Responds to changes of slope as small as 0.000006”/ft.
- High accuracy closed-loop force balanced sensor technology.
- Low white noise spectral density of better than 0.15μV/Sq.
- Root HZ
- RoHS compliant
About the LSO Single-Axis Analog Inclinometer
The LSO Series fluid damped, flexure suspesion, servo inclinometer is a precision internal grade sensing instruments and it is a robust solution designed to meet the needs of a variety of commercial, industrial and aerospace applications.
Suitable applications
- Steel Processing
- Continuous Casting
- Electric Arc Furnace
- Idle Control
- Heavy construction
- Paving
- Grading
- Mining
- Tunneling
- Overturn Detection
- Structural Monitoring
- Automated Train Controls
- Rail Leveling and Grinding
- Rail Bed Analysis
Available configurations
Units are available with a 6-pin connector, or pin-terminals and in ±5V and 4-20mA outputs. Download the datasheet for specifications per configuration.
- LSOP (Pin)
- LSOC (Connector)
Do you need this sensor for your next project?
Request a quotation today or leave your details to recieve more information from one of our experts.
Product downloads
Have it your way
Not exactly what you’re looking for? We offer standard sensors but can also help you with a tailor-made sensor or a complete measuring solution. Please contact us for advice or budgetary pricing.
Talk to an expertTechnical Specifications
Specification | Value |
---|---|
Constant acceleration overload | 50 g |
Emc directive | EN61326: 1998 |
Emc emissions | EN55022: 1998, 30 MHz to 1 GHz |
Emc immunity | EN61000-4-2: 1995 inc A1: 1998 & A2: 2001, ±4 kV |
Emc immunity | EN61000-4-3: 2002, 10 V/m |
Emc immunity | EN61000-4-4: 2004, ±1 kV |
Emc immunity | EN61000-4-6: 1996 inc A1: 2001, 3 Vrms |
Emc immunity | EN61000-4-6: 2007, 10 Vrms |
Emc immunity | EN61000-4-8: 1994 inc A1 : 2001, 30 A/m |
Environmental sealing | IP65 |
Operating temperature range | -18 to +70 °C |
Shock survival | 1500 g, 0.5 ms, ½ sine |
Survival temperature range | -40 to +70 °C |
Vibration endurance | 35 g rms, 20 Hz to 2000 Hz sinusoidal |
Related products
Need something else?
PNS Digital Display
- Measurement range ±1° to 90°, depending on inclinometer
- Power supply 24 VDC with external power supply
- Display of the inclination in Degree, %, mm/m or Grad:min:s
LSOX Single-Axis Analog Inclinometer
- Ranges available from ±1.0° to ±90.0°
- High Accuracy fluid damped inclinometer
- RoHS Compliant
LSRP Single-Axis Analog Inclinometer
- Ranges available from ±1° to ±90
- Extremely sensitive, rugged transducer
- RoHS compliant