FTP Bending Shear Beam Load Cell
Protection rating IP68
Do you need this sensor for your next project?
Request a no-obligation quote or send us your contact details for a free, no-obligation consultation. Our sales engineers will then contact you within a maximum of 1 to 2 working days.
Product downloads
Talk to our experts
Not exactly what you are looking for? We offer standard sensors, but can also help you with sensors adapted for you or a fully customised measurement solution. Contact us for advice or pricing.
Talk to an expertTechnical Specifications
| Specification | Value |
|---|---|
| Combined error | ≤±0.02% |
| Compensated temperature range | -10 °C / +40 °C |
| Creep at nominal load in 30 minutes | 0.03% |
| Deflection at nominal load | 0.4 mm |
| Input resistance | 385 Ω ±10 | 400 Ω ±15 |
| Insulation resistance | ≥5000 MΩ |
| Material | AISI 420 stainless steel |
| Max supply voltage without damage | 15 V |
| Minimum verification interval (v min) | E max / 12000 | - |
| Nominal load (e max) | 75 -150 - 300 - 500 kg, 1000 -1200 - 1500 - 2000 kg | 3000 - 5000 - 10000 kg |
| Oiml r60 accuracy class • verification intervals | C3 • 3000 | - |
| Operating temperature range | -20 °C / +70 °C |
| Output resistance | 350 Ω ±3 | 350 Ω ±5 |
| Protection class | IP67 (75 - 300 kg), IP68 (500 - 10000 kg) |
| Rated output | 2 mV/V ±0.1% |
| Safe overload (% of full scale) | 150% |
| Temperature effect on span | 0.0012% °C |
| Temperature effect on zero | 0.002% °C |
| Ultimate overload (% of full scale) | 200% |
| Zero balance | ±2% |
Related products
Need something else?
T12 Weight Module for Loadcells
- Range: 30 to 2000kg
- Upper plate with a compression joint in AISI 304 stainless steel and rubber.
- Lower plate and block in galvanized steel