For platforms 400 x 400mm


Key features

  • Range: 60 to 300kg
  • Aluminium alloy loadcell
  • Combined error < +/- 0.02% (0.017% C4; 0.014% C5)
  • Protection class IP 65
  • Accuracy class C3/C4/C5 (OIML R60)

General information


The AM platform load cell is suitable for series use in weighing and batching systems, level measurement equipment and general force measurement systems where accurate measurements are required at low cost.

Features

  • Measuring range: 60 - 300kg
  • Aluminum construction
  • Combined error: < ±0.02% (0.017% C4; 0.014% C5)
  • Supply voltage: 18V
  • Protection class: IP65

Do you need this sensor for your next project?

Request a no-obligation quote or send us your contact details for a free, no-obligation consultation. Our sales engineers will then contact you within a maximum of 1 to 2 working days.

Talk to an expert

Talk to our experts

Not exactly what you are looking for? We offer standard sensors, but can also help you with sensors adapted for you or a fully customised measurement solution. Contact us for advice or pricing.

Talk to an expert

Technical Specifications

Specification Value
Combined error ≤±0.02% | ≤±0.017% | ≤±0.014%
Compensated temperature range -10 °C / +40 °C
Creep at nominal load in 30 minutes 0.025%
Deflection at nominal load 0.5 mm
Input resistance 406 Ω ±6
Insulation resistance ≥5000 MΩ
Material Aluminum alloy
Max supply voltage without damage 18 V
Minimum verification interval (vₘᵢₙ) Eₘₐₓ / 10000 | Eₘₐₓ / 15000 | Eₘₐₓ / 20000
Nominal load (eₘₐₓ) 60 - 100 - 150 - 200 - 300 kg
Oiml r60 accuracy class • verification intervals C3 • 3000 | C4 • 4000 | C5 • 5000
Operating temperature range -35 °C / +65 °C
Output resistance 350 Ω ±3
Protection class IP65
Rated output 2 mV/V ±10%
Safe overload (% of full scale) 150%
Temperature effect on span 0.002% °C
Temperature effect on zero 0.003% °C
Ultimate overload (% of full scale) 300%
Zero balance ≤±2%