1. Althen Sensors
  2. Sensors
  3. Weighing sensors and load cells
  4. Cylindrical load cells
  5. FLC 3A Hygienic Ccompression Lload cell
  • FLC3A sensor with display
  • FLC3A_2 sensor with display
  • CDG3A sensor with display

FLC 3A Hygienic Ccompression Lload cell

Hygienic stainless steel load cell for food, pharma, and cleanroom compression applications. IP69K rated with 3-A SSI certification.

View technical specifications

Key features

  • 17-4 PH stainless steel construction
  • IP69K protection for hygienic environments
  • 3-A SSI certified for food-grade use
  • Combined error ≤ ±0.1%
  • Adjustable height
  • Cable suitable for contact with food

About the FLC 3A Hygienic compression load cell

The FLC 3A is a high-precision compression load cell with a combined error of ≤ ±0.1%, offering a stable 2.0 mV/V ± 0.1% output signal. Designed to perform in demanding hygiene-sensitive environments, it covers a nominal load range from 1,000 to 20,000 kg.

Usage conditions

Built in 17-4 PH stainless steel and rated IP69K, this sensor withstands high-pressure cleaning and meets strict hygiene protocols. Its integrated cable is certified food-grade, ensuring compliance in pharmaceutical and food processing applications.

Possible applications:

  • Food and beverage production lines
  • Cleanroom equipment force monitoring
  • Hygienic tank weighing systems
  • Pharmaceutical packaging machines
  • Biotech and lab automation
  • Dairies, meat processing and bakeries

Advantages of choosing this product

Thanks to its 3-A SSI certification, the FLC 3A is approved for use in highly regulated sectors. Its robust yet compact design with adjustable height ensures flexible integration, while its electrical stability and corrosion-resistant material make it a long-lasting solution.

Other important features:

  • Compatible hygienic foot with ±15° angular adjustment (Ø120 mm)
  • Multiple thread sizes: M12 to M36
  • Wide temperature operating range from -20 °C to +70 °C
  • Overload protection up to 300% of nominal load
  • Load cell kits with foot available for different capacities

Do you need this sensor for your next project?

Request a no-obligation quote or send us your contact details for a free, no-obligation consultation. Our sales engineers will then contact you within a maximum of 1 to 2 working days.

Talk to an expert

Talk to our experts

Not exactly what you are looking for? We offer standard sensors, but can also help you with sensors adapted for you or a fully customised measurement solution. Contact us for advice or pricing.

Talk to an expert

Technical Specifications

Specification Value
Nominal load 1000 - 2000 - 5000 - 10000 - 20000 kg
Combined error ≤±0.1%
Rated output 2.0 mV/V ±0.1%
Temperature effect on zero 0.005% °C
Temperature effect on span 0.005% °C
Compensated temperature range -10 °C / +50 °C
Creep at nominal load in 30 minutes 0.05%
Max supply voltage without damage 5 ÷ 15 VDC
Protection class IP69K
Input resistance 350 Ω ±20
Output resistance 350 Ω ±5